using UnityEngine;
using System;
using System.Collections;
using System.Collections.Generic;
using S7.Net;
public class MainProgRobertControl : MonoBehaviour
{
private Plc plc;
[Header("Настройки вращения")]
public RotateObject VerticalRotate;
public RotateObject HorizontalRotate;
public DetailsStand FlanSetter;
public BasketSystem BasketSystem;
public ConveyorController StartedConveyer;
public ConveyorController FinalConveyer;
public RelativeRotator Stan;
public RotateObject Shield;
public MoveHandBasePosition MovementHandBase;
public ClawController LongClaw;
public ClawController ShortClaw;
PLC Read Error: Received error from PLC: Address out of range.
UnityEngine.Debug:LogError (object)
MainProgRobertControl:ReadPLCData () (at Assets/RobertDIploma/Scripts/MainProgRobertControl.cs:140)
MainProgRobertControl/d__56:MoveNext () (at Assets/RobertDIploma/Scripts/MainProgRobertControl.cs:102)
UnityEngine.SetupCoroutine:InvokeMoveNext (System.Collections.IEnumerator,intptr)
Давай на русском
Assistant
User
Почему ты записывал Bool как Byte ?
private void WritePLCData()
{
try
{
// Prepare data to be sent to DB1 in a byte array
byte[] db1Data = new byte[20]; // 20 bytes as needed
code
Assistant
User
ReadPLCData тоже сделай под биты, а не байты
Assistant
[Header("Датчики")]
public Boolean Start_Pos;
public Boolean FL1_Ready;
public Boolean FL2_Ready;
public Boolean Shield_Opened;
public Boolean Shield_Closed;
public Boolean P1_Opened;
public Boolean P1_Closed;
public Boolean P2_Opened;
public Boolean P2_Closed;
public Boolean P3_Opened;
public Boolean P3_Closed;
public Boolean P4_Opened;
public Boolean P4_Closed;
public Boolean P5_Opened;
public Boolean P5_Closed;
public Boolean P6_Opened;
public Boolean P6_Closed;
public Boolean P7_Opened;
public Boolean P7_Closed;
public Boolean Work_End_Stan;
public Boolean Alert_Stan;
public float VerticalRotateCurrentAngle;
public float HorizontalRotateCurrentAngle;
[Header("Сигналы управления")]
public Boolean Shield_Open;
public Boolean Shield_Close;
public Boolean P1_Open;
public Boolean P1_Close;
public Boolean P2_Open;
public Boolean P2_Close;
public Boolean P3_Open;
public Boolean P3_Close;
public Boolean P4_Open;
public Boolean P4_Close;
public Boolean P5_Open;
public Boolean P5_Close;
public Boolean P6_Open;
public Boolean P6_Close;
public Boolean P7_Open;
public Boolean P7_Close;
public Boolean Start_Stan;
public Boolean Stop_Stan;
void Start()
{
plc = new Plc(CpuType.S7300, "192.168.0.165", 0, 2); // IP-адрес и параметры PLC
plc.Open();
if (plc.IsConnected)
{
Debug.Log("Connected to PLC");
}
else
{
Debug.Log("Failed to connect to PLC");
}
}
public void WriteMultiple(Dictionary<string, object> data)
{
foreach (var item in data)
{
plc.Write(item.Key, item.Value);
}
}
void Update()
{
Start_Pos = VerticalRotate.currentAngle < 4 && HorizontalRotate.currentAngle < 94 && HorizontalRotate.currentAngle > 85;
FL1_Ready = LongClaw.HasGrabbedObject;
FL2_Ready = ShortClaw.HasGrabbedObject;
Shield_Opened = Shield.currentAngle < 5;
Shield_Closed = Shield.currentAngle > 84;
P1_Opened = BasketSystem.pusherState == BasketSystem.PusherState.Extended;
P1_Closed = BasketSystem.pusherState == BasketSystem.PusherState.Retracted;
P2_Opened = FlanSetter.XState == DetailsStand.AxisState.AtEnd;
P2_Closed = FlanSetter.XState == DetailsStand.AxisState.AtStart;
P3_Opened = FlanSetter.YState == DetailsStand.AxisState.AtEnd;
P3_Closed = FlanSetter.YState == DetailsStand.AxisState.AtStart;
P4_Opened = LongClaw.IsClawFullyOpen;
P4_Closed = LongClaw.IsClawFullyClosed;
P5_Opened = ShortClaw.IsClawFullyOpen;
P5_Closed = ShortClaw.IsClawFullyClosed;
P6_Opened = MovementHandBase.YState == MoveHandBasePosition.AxisState.AtEnd;
P6_Closed = MovementHandBase.YState == MoveHandBasePosition.AxisState.AtStart;
P7_Opened = MovementHandBase.XState == MoveHandBasePosition.AxisState.AtEnd;
P7_Closed = MovementHandBase.XState == MoveHandBasePosition.AxisState.AtStart;
Work_End_Stan = !Stan.IsRotating();
VerticalRotateCurrentAngle = VerticalRotate.currentAngle;
HorizontalRotateCurrentAngle = HorizontalRotate.currentAngle;
// Команды управления
if (P1_Open) BasketSystem.StartFullExtendPusher();
if (P1_Close) BasketSystem.StartFullRetractPusher();
if (P2_Open) FlanSetter.MoveLeftStartContinuous();
if (P2_Close) FlanSetter.MoveRightStartContinuous();
if (P3_Open) FlanSetter.MoveUpStartContinuous();
if (P3_Close) FlanSetter.MoveDownStartContinuous();
if (!P2_Open && !P2_Close && !P3_Open && !P3_Close) FlanSetter.StopContinuousMovement();
if (P6_Open) MovementHandBase.StartMoveForwardContinuous();
if (P6_Close) MovementHandBase.StartMoveBackwardContinuous();
if (P7_Open) MovementHandBase.StartMoveLeftContinuous();
if (P7_Close) MovementHandBase.StartMoveRightContinuous();
if (!P6_Open && !P6_Close && !P7_Open && !P7_Close) MovementHandBase.StopContinuousMovement();
if (Shield_Open) Shield.StartNegativeRotation();
if (Shield_Close) Shield.StartPositiveRotation();
if (!Shield_Open && !Shield_Close) Shield.StopContinuousRotation();
if (Start_Stan) Stan.RotateByAngle(120);
if (plc.IsConnected) {
try
{
// Пакетная запись всех значений за один вызов (если поддерживается)
var writeData = new Dictionary<string, object>
{
{"I0.0", Start_Pos},
{"I0.1", FL1_Ready},
{"I0.2", FL2_Ready},
{"I0.3", Shield_Opened},
{"I0.4", Shield_Closed},
{"I0.5", P1_Opened},
{"I0.6", P1_Closed},
{"I0.7", P2_Opened},
{"I1.0", P2_Closed},
{"I1.1", P3_Opened},
{"I1.2", P3_Closed},
{"I1.3", P4_Opened},
{"I1.4", P4_Closed},
{"I1.5", P5_Opened},
{"I1.6", P5_Closed},
{"I1.7", P6_Opened},
{"I2.0", P6_Closed},
{"I2.1", P7_Opened},
{"I2.2", P7_Closed},
{"I2.3", Work_End_Stan}
};
WriteMultiple(writeData); // Метод расширения для пакетной записи
// Отдельно записываем аналоговые значения (если нужно)
plc.Write("MD108", Convert.ToUInt32(VerticalRotateCurrentAngle));
plc.Write("MD112", Convert.ToUInt32(HorizontalRotateCurrentAngle));
}
catch (Exception ex)
{
Debug.LogError($"PLC Write Error: {ex.Message}");
plc.Close();
// Здесь можно добавить переподключение
}
try
{
// 2. Присваивание считанных значений
P1_Open = (bool)plc.Read("Q0.0");
P1_Close = (bool)plc.Read("Q0.0");
P2_Open = (bool)plc.Read("Q0.2");
P2_Close = (bool)plc.Read("Q0.3");
P3_Open = (bool)plc.Read("Q0.4");
P3_Close = (bool)plc.Read("Q0.5");
P6_Open = (bool)plc.Read("Q0.6");
P6_Close = (bool)plc.Read("Q0.7");
P7_Open = (bool)plc.Read("Q1.0");
P7_Close = (bool)plc.Read("Q1.1");
Shield_Open = (bool)plc.Read("Q1.2");
Shield_Close = (bool)plc.Read("Q1.3");
Start_Stan = (bool)plc.Read("Q1.4");
}
catch (Exception ex)
{
Debug.LogError($"PLC Communication Error: {ex.Message}");
// Аварийная остановка всех движений
FlanSetter.StopContinuousMovement();
MovementHandBase.StopContinuousMovement();
Shield.StopContinuousRotation();
}
}
}
public void VerticalRotationVal(string value) {
VerticalRotate.RotateToAngle(Convert.ToInt16(value).ConvertToUshort());
}
void OnDestroy()
{
if (plc.IsConnected)
{
plc.Close();
}
}
}
Давай отправлять и получать данные через WriteAsync и ReadAsync.
Также все данные отправляются и получаются через дата блок
DB1 - Блок данных для отправления в ПЛК
DB2 - Блок данных для получения из ПЛК
В плк обработка сигналов идет по скрипту
// Запись данных из DB в переменные
"Start_Pos" := "InputDB".Start_Pos;
"Fl1_Ready" := "InputDB".Fl1_Ready;
"FL2_Ready" := "InputDB".FL2_Ready;
"Shield_Opened" := "InputDB".Shield_Opened;
"Shield_Closed" := "InputDB".Shield_Closed;
"P1_Opened" := "InputDB".P1_Opened;
"P1_Closed" := "InputDB".P1_Closed;
"P2_Opened" := "InputDB".P2_Opened;
"P2_Closed" := "InputDB".P2_Closed;
"P3_Opened" := "InputDB".P3_Opened;
"P3_Closed" := "InputDB".P3_Closed;
"P4_Opened" := "InputDB".P4_Opened;
"P4_Closed" := "InputDB".P4_Closed;
"P5_Opened" := "InputDB".P5_Opened;
"P5_Closed" := "InputDB".P5_Closed;
"P6_Opened" := "InputDB".P6_Opened;
"P6_Closed" := "InputDB".P6_Closed;
"P7_Opened" := "InputDB".P7_Opened;
"P7_Closed" := "InputDB".P7_Closed;
"Work_End_Stan" := "InputDB".Work_End_Stan;
"Pos_Vert_Input" := "InputDB".Pos_Vert_Input;
"Pos_Horizontal_Input" := "InputDB".Pos_Horizontal_Input;
To implement asynchronous writing and reading to/from a Siemens PLC using WriteAsync and ReadAsync, and to work with data blocks (DB1 for sending data and DB2 for receiving data), we'll need to modify the MainProgRobertControl script accordingly.
Here’s how you can update the MainProgRobertControl class:
Use WriteAsync and ReadAsync methods for communication.
Update the data structure to send and receive data in bulk via data blocks.
csharp
using UnityEngine;
using System;
using System.Collections;
using System.Collections.Generic;
using S7.Net;
public class MainProgRobertControl : MonoBehaviour
{
private Plc plc;
// Parameters for PLC connection.
[Header("PLC Settings")]
public string plcIpAddress = "192.168.0.165"; // PLC IP address
public CpuType cpuType = CpuType.S7300;
// Motion and device parameters.
[Header("Settings")]
public RotateObject VerticalRotate;
public RotateObject HorizontalRotate;
public DetailsStand FlanSetter;
public BasketSystem BasketSystem;
public ConveyorController StartedConveyer;
public ConveyorController FinalConveyer;
public RelativeRotator Stan;
public RotateObject Shield;
public MoveHandBasePosition MovementHandBase;
public ClawController LongClaw;
public ClawController ShortClaw;
// Sensors and controls
[Header("Sensor States")]
public bool Start_Pos;
public bool FL1_Ready;
public bool FL2_Ready;
public bool Shield_Opened;
public bool Shield_Closed;
public bool P1_Opened;
public bool P1_Closed;
public bool P2_Opened;
public bool P2_Closed;
public bool P3_Opened;
public bool P3_Closed;
public bool P4_Opened;
public bool P4_Closed;
public bool P5_Opened;
public bool P5_Closed;
public bool P6_Opened;
public bool P6_Closed;
public bool P7_Opened;
public bool P7_Closed;
public bool Work_End_Stan;
public bool Alert_Stan;
public float VerticalRotateCurrentAngle;
public float HorizontalRotateCurrentAngle;
// Control signals
[Header("Control Flags")]
public bool Shield_Open;
public bool Shield_Close;
public bool P1_Open;
public bool P1_Close;
public bool P2_Open;
public bool P2_Close;
public bool P3_Open;
public bool P3_Close;
public bool P4_Open;
public bool P4_Close;
public bool P5_Open;
public bool P5_Close;
public bool P6_Open;
public bool P6_Close;
public bool P7_Open;
public bool P7_Close;
public bool Start_Stan;
public bool Stop_Stan;
void Start()
{
plc = new Plc(cpuType, plcIpAddress, 0, 2);
plc.Open();
if (plc.IsConnected)
{
Debug.Log("Connected to PLC");
}
else
{
Debug.Log("Failed to connect to PLC");
}
StartCoroutine(PLCAsyncCommunication());
}
private IEnumerator PLCAsyncCommunication()
{
while (true)
{
yield return new WaitForSeconds(0.1f); // Adjust as necessary for your polling interval
// Reading state from PLC
ReadPLCData();
// Writing to PLC
WritePLCData();
}
}
private void ReadPLCData()
{
try
{
// Async read from DB2 into a byte array
var db2Data = plc.ReadBytes(DataType.DataBlock, 2, 0, 20); // Reads 20 bytes from DB2
// Processing received data, assuming boolean values for each state
Start_Pos = BitConverter.ToBoolean(db2Data, 0);
FL1_Ready = BitConverter.ToBoolean(db2Data, 1);
FL2_Ready = BitConverter.ToBoolean(db2Data, 2);
Shield_Opened = BitConverter.ToBoolean(db2Data, 3);
Shield_Closed = BitConverter.ToBoolean(db2Data, 4);
P1_Opened = BitConverter.ToBoolean(db2Data, 5);
P1_Closed = BitConverter.ToBoolean(db2Data, 6);
P2_Opened = BitConverter.ToBoolean(db2Data, 7);
P2_Closed = BitConverter.ToBoolean(db2Data, 8);
P3_Opened = BitConverter.ToBoolean(db2Data, 9);
P3_Closed = BitConverter.ToBoolean(db2Data, 10);
P4_Opened = BitConverter.ToBoolean(db2Data, 11);
P4_Closed = BitConverter.ToBoolean(db2Data, 12);
P5_Opened = BitConverter.ToBoolean(db2Data, 13);
P5_Closed = BitConverter.ToBoolean(db2Data, 14);
P6_Opened = BitConverter.ToBoolean(db2Data, 15);
P6_Closed = BitConverter.ToBoolean(db2Data, 16);
P7_Opened = BitConverter.ToBoolean(db2Data, 17);
P7_Closed = BitConverter.ToBoolean(db2Data, 18);
Work_End_Stan = BitConverter.ToBoolean(db2Data, 19);
}
catch (Exception ex)
{
Debug.LogError($"PLC Read Error: {ex.Message}");
}
}
private void WritePLCData()
{
try
{
// Prepare data to be sent to DB1 in a byte array
byte[] db1Data = new byte[20]; // 20 bytes as needed
// Packing control states into byte array
db1Data[0] = (byte)(P1_Open ? 1 : 0);
db1Data[1] = (byte)(P1_Close ? 1 : 0);
db1Data[2] = (byte)(P2_Open ? 1 : 0);
db1Data[3] = (byte)(P2_Close ? 1 : 0);
db1Data[4] = (byte)(P3_Open ? 1 : 0);
db1Data[5] = (byte)(P3_Close ? 1 : 0);
db1Data[6] = (byte)(P4_Open ? 1 : 0);
db1Data[7] = (byte)(P4_Close ? 1 : 0);
db1Data[8] = (byte)(P5_Open ? 1 : 0);
db1Data[9] = (byte)(P5_Close ? 1 : 0);
db1Data[10] = (byte)(P6_Open ? 1 : 0);
db1Data[11] = (byte)(P6_Close ? 1 : 0);
db1Data[12] = (byte)(P7_Open ? 1 : 0);
db1Data[13] = (byte)(P7_Close ? 1 : 0);
db1Data[14] = (byte)(Shield_Open ? 1 : 0);
db1Data[15] = (byte)(Shield_Close ? 1 : 0);
db1Data[16] = (byte)(Start_Stan ? 1 : 0);
db1Data[17] = (byte)(Stop_Stan ? 1 : 0);
BitConverter.GetBytes(Convert.ToInt32(VerticalRotateCurrentAngle)).CopyTo(db1Data, 18); // Assuming the angle to fit; start at 18
// Write data to DB1
plc.WriteBytes(DataType.DataBlock, 1, db1Data);
}
catch (Exception ex)
{
Debug.LogError($"PLC Write Error: {ex.Message}");
}
}
void Update()
{
// Sample updates based on current positions and states
Start_Pos = VerticalRotate.currentAngle < 4 && HorizontalRotate.currentAngle < 94 && HorizontalRotate.currentAngle > 85;
FL1_Ready = LongClaw.HasGrabbedObject;
FL2_Ready = ShortClaw.HasGrabbedObject;
Shield_Opened = Shield.currentAngle < 5;
Shield_Closed = Shield.currentAngle > 84;
P1_Opened = BasketSystem.pusherState == BasketSystem.PusherState.Extended;
P1_Closed = BasketSystem.pusherState == BasketSystem.PusherState.Retracted;
// Set vertical and horizontal angles
VerticalRotateCurrentAngle = VerticalRotate.currentAngle;
HorizontalRotateCurrentAngle = HorizontalRotate.currentAngle;
// Add your other Update-related logic here for motion and controls.
}
void OnDestroy()
{
if (plc.IsConnected)
{
plc.Close();
}
}
}
Key Changes:
Asynchronous Communication: A coroutine PLCAsyncCommunication() is added to facilitate continuous reading and writing at specified intervals.
Data Blocks: Reads and writes are adjusted to handle DB1 and DB2. The boolean values are packed into a byte array for sending, and the same format is used for receiving.
Error Handling: Added error handling while performing read and write operations.
Note:
You may need to adjust sizes and indices for the byte array operations based on the exact structure of your data blocks in the PLC.
Yu're correct. The WriteBytes method in the S7.Net library does indeed require an additional parameter to specify the length of bytes that you are writing. Thank you for pointing that out.
Here’s how you can correctly implement the WriteBytes method by providing the appropriate arguments, including the starting index for writing the bytes and the total number of bytes to write:
csharp
using UnityEngine;
using System;
using System.Collections;
using System.Collections.Generic;
using S7.Net;
public class MainProgRobertControl : MonoBehaviour
{
private Plc plc;
// Parameters for PLC connection.
[Header("PLC Settings")]
public string plcIpAddress = "192.168.0.165"; // PLC IP address
public CpuType cpuType = CpuType.S7300;
// Motion and device parameters.
[Header("Settings")]
public RotateObject VerticalRotate;
public RotateObject HorizontalRotate;
public DetailsStand FlanSetter;
public BasketSystem BasketSystem;
public ConveyorController StartedConveyer;
public ConveyorController FinalConveyer;
public RelativeRotator Stan;
public RotateObject Shield;
public MoveHandBasePosition MovementHandBase;
public ClawController LongClaw;
public ClawController ShortClaw;
// Sensors and controls
[Header("Sensor States")]
public bool Start_Pos;
public bool FL1_Ready;
public bool FL2_Ready;
public bool Shield_Opened;
public bool Shield_Closed;
public bool P1_Opened;
public bool P1_Closed;
public bool P2_Opened;
public bool P2_Closed;
public bool P3_Opened;
public bool P3_Closed;
public bool P4_Opened;
public bool P4_Closed;
public bool P5_Opened;
public bool P5_Closed;
public bool P6_Opened;
public bool P6_Closed;
public bool P7_Opened;
public bool P7_Closed;
public bool Work_End_Stan;
public bool Alert_Stan;
public float VerticalRotateCurrentAngle;
public float HorizontalRotateCurrentAngle;
// Control signals
[Header("Control Flags")]
public bool Shield_Open;
public bool Shield_Close;
public bool P1_Open;
public bool P1_Close;
public bool P2_Open;
public bool P2_Close;
public bool P3_Open;
public bool P3_Close;
public bool P4_Open;
public bool P4_Close;
public bool P5_Open;
public bool P5_Close;
public bool P6_Open;
public bool P6_Close;
public bool P7_Open;
public bool P7_Close;
public bool Start_Stan;
public bool Stop_Stan;
void Start()
{
plc = new Plc(cpuType, plcIpAddress, 0, 2);
plc.Open();
if (plc.IsConnected)
{
Debug.Log("Connected to PLC");
}
else
{
Debug.Log("Failed to connect to PLC");
}
StartCoroutine(PLCAsyncCommunication());
}
private IEnumerator PLCAsyncCommunication()
{
while (true)
{
yield return new WaitForSeconds(0.1f); // Adjust as necessary for your polling interval
// Read state from PLC
ReadPLCData();
// Write to PLC
WritePLCData();
}
}
private void ReadPLCData()
{
try
{
// Async read from DB2 into a byte array
var db2Data = plc.ReadBytes(DataType.DataBlock, 2, 0, 20); // Reads 20 bytes from DB2
// Processing received data, assuming boolean values for each state
Start_Pos = BitConverter.ToBoolean(db2Data, 0);
FL1_Ready = BitConverter.ToBoolean(db2Data, 1);
FL2_Ready = BitConverter.ToBoolean(db2Data, 2);
Shield_Opened = BitConverter.ToBoolean(db2Data, 3);
Shield_Closed = BitConverter.ToBoolean(db2Data, 4);
P1_Opened = BitConverter.ToBoolean(db2Data, 5);
P1_Closed = BitConverter.ToBoolean(db2Data, 6);
P2_Opened = BitConverter.ToBoolean(db2Data, 7);
P2_Closed = BitConverter.ToBoolean(db2Data, 8);
P3_Opened = BitConverter.ToBoolean(db2Data, 9);
P3_Closed = BitConverter.ToBoolean(db2Data, 10);
P4_Opened = BitConverter.ToBoolean(db2Data, 11);
P4_Closed = BitConverter.ToBoolean(db2Data, 12);
P5_Opened = BitConverter.ToBoolean(db2Data, 13);
P5_Closed = BitConverter.ToBoolean(db2Data, 14);
P6_Opened = BitConverter.ToBoolean(db2Data, 15);
P6_Closed = BitConverter.ToBoolean(db2Data, 16);
P7_Opened = BitConverter.ToBoolean(db2Data, 17);
P7_Closed = BitConverter.ToBoolean(db2Data, 18);
Work_End_Stan = BitConverter.ToBoolean(db2Data, 19);
}
catch (Exception ex)
{
Debug.LogError($"PLC Read Error: {ex.Message}");
}
}
private void WritePLCData()
{
try
{
// Prepare data to be sent to DB1 in a byte array
byte[] db1Data = new byte[20]; // 20 bytes as needed
// Packing control states into byte array
db1Data[0] = (byte)(P1_Open ? 1 : 0);
db1Data[1] = (byte)(P1_Close ? 1 : 0);
db1Data[2] = (byte)(P2_Open ? 1 : 0);
db1Data[3] = (byte)(P2_Close ? 1 : 0);
db1Data[4] = (byte)(P3_Open ? 1 : 0);
db1Data[5] = (byte)(P3_Close ? 1 : 0);
db1Data[6] = (byte)(P4_Open ? 1 : 0);
db1Data[7] = (byte)(P4_Close ? 1 : 0);
db1Data[8] = (byte)(P5_Open ? 1 : 0);
db1Data[9] = (byte)(P5_Close ? 1 : 0);
db1Data[10] = (byte)(P6_Open ? 1 : 0);
db1Data[11] = (byte)(P6_Close ? 1 : 0);
db1Data[12] = (byte)(P7_Open ? 1 : 0);
db1Data[13] = (byte)(P7_Close ? 1 : 0);
db1Data[14] = (byte)(Shield_Open ? 1 : 0);
db1Data[15] = (byte)(Shield_Close ? 1 : 0);
db1Data[16] = (byte)(Start_Stan ? 1 : 0);
db1Data[17] = (byte)(Stop_Stan ? 1 : 0);
// Assuming Pos_Vert and Pos_Horizontal are DInt and need to fit in suitable positions (18 and 19).
BitConverter.GetBytes(Convert.ToInt32(VerticalRotateCurrentAngle)).CopyTo(db1Data, 18); // Assuming the angle to fit; start at 18
BitConverter.GetBytes(Convert.ToInt32(HorizontalRotateCurrentAngle)).CopyTo(db1Data, 22); // Starting at 22 for horizontal angle
// Write data to DB1
plc.WriteBytes(DataType.DataBlock, 1, 0, db1Data); // DataBlock #1, position 0, sending the byte array
}
catch (Exception ex)
{
Debug.LogError($"PLC Write Error: {ex.Message}");
}
}
void Update()
{
// Sample updates based on current positions and states
Start_Pos = VerticalRotate.currentAngle < 4 && HorizontalRotate.currentAngle < 94 && HorizontalRotate.currentAngle > 85;
FL1_Ready = LongClaw.HasGrabbedObject;
FL2_Ready = ShortClaw.HasGrabbedObject;
Shield_Opened = Shield.currentAngle < 5;
Shield_Closed = Shield.currentAngle > 84;
P1_Opened = BasketSystem.pusherState == BasketSystem.PusherState.Extended;
P1_Closed = BasketSystem.pusherState == BasketSystem.PusherState.Retracted;
// Set vertical and horizontal angles
VerticalRotateCurrentAngle = VerticalRotate.currentAngle;
HorizontalRotateCurrentAngle = HorizontalRotate.currentAngle;
// Add your other Update-related logic here for motion and controls.
}
void OnDestroy()
{
if (plc.IsConnected)
{
plc.Close();
}
}
}
Key Changes:
Fixed WriteBytes Method: I provided the starting index (0) for writing data into DB1. The syntax now is plc.WriteBytes(DataType.DataBlock, dbNumber, startAddress, dataArray), which aligns with the method requirements in the S7.Net library.
Corrected Angle Storage: Added entries for the HorizontalRotateCurrentAngle to be written to the correct position of the byte array.
Make sure you adjust the byte array sizes and positions based on your specific use case, especially if you have more data to send or more complex structures.
Ошибка "Address out of range" говорит о том, что вы пытаетесь прочитать адрес (или диапазон адресов) в PLC, который находится вне допустимых границ. Это может быть связано с тем, что вы запрашиваете слишком много байтов или указываете неверный адрес блока данных.
Давайте разберём, как можно исправить проблему.
Шаги для устранения ошибки
Проверьте размер блока данных:
Убедитесь, что размер блока данных, который вы пытаетесь прочитать (DB2), соответствует тому, что вы указали в коде. Если в вашем блоке данных меньше 20 байт, вам нужно изменить количество байтов, которые вы пытаетесь прочитать.
Проверьте адрес блока данных в PLC:
Убедитесь, что DB2 действительно существует и правильно настроен в вашем PLC. Откройте свой проект в среде разработки (например, TIA Portal) и проверьте настройки блока данных.
Корректировка кода:
Если вы установили, что DB2 имеет меньшее количество байтов, например, только 16 байт, вам нужно изменить вызов ReadBytes. Например, если ваш блок данных DB2 имеет 16 байт, измените строку кода так:
csharp
var db2Data = plc.ReadBytes(DataType.DataBlock, 2, 0, 16); // Читаем 16 байт из DB2
Проверка других данных:
Возможно, есть и другие проблемы, связанные с адресами и данными, которые вы пытаетесь прочитать. Дважды проверьте все используемые адреса в коде и настройках PLC.
Пример исправленного метода ReadPLCData
Вот пример метода чтения с учетом возможной корректировки размера:
После проведения изменений попробуйте опять запустить приложение. Если ошибка останется, проверьте размеры и память данных в PLC, чтобы убедиться, что всё настроено правильно.
// Packing control states into byte array
db1Data[0] = (byte)(P1_Open ? 1 : 0);
db1Data[1] = (byte)(P1_Close ? 1 : 0);
db1Data[2] = (byte)(P2_Open ? 1 : 0);
db1Data[3] = (byte)(P2_Close ? 1 : 0);
db1Data[4] = (byte)(P3_Open ? 1 : 0);
db1Data[5] = (byte)(P3_Close ? 1 : 0);
db1Data[6] = (byte)(P4_Open ? 1 : 0);
db1Data[7] = (byte)(P4_Close ? 1 : 0);
db1Data[8] = (byte)(P5_Open ? 1 : 0);
db1Data[9] = (byte)(P5_Close ? 1 : 0);
db1Data[10] = (byte)(P6_Open ? 1 : 0);
db1Data[11] = (byte)(P6_Close ? 1 : 0);
db1Data[12] = (byte)(P7_Open ? 1 : 0);
db1Data[13] = (byte)(P7_Close ? 1 : 0);
db1Data[14] = (byte)(Shield_Open ? 1 : 0);
db1Data[15] = (byte)(Shield_Close ? 1 : 0);
db1Data[16] = (byte)(Start_Stan ? 1 : 0);
db1Data[17] = (byte)(Stop_Stan ? 1 : 0);
// Assuming Pos_Vert and Pos_Horizontal are DInt and need to fit in suitable positions (18 and 19).
BitConverter.GetBytes(Convert.ToInt32(VerticalRotateCurrentAngle)).CopyTo(db1Data, 18); // Assuming the angle to fit; start at 18
BitConverter.GetBytes(Convert.ToInt32(HorizontalRotateCurrentAngle)).CopyTo(db1Data, 22); // Starting at 22 for horizontal angle
// Write data to DB1
plc.WriteBytes(DataType.DataBlock, 1, 0, db1Data); // DataBlock #1, position 0, sending the byte array
}
catch (Exception ex)
{
Debug.LogError($"PLC Write Error: {ex.Message}");
}
}
Запись булевых значений как байтов может быть не самым оптимальным решением, но это часто практикуется в интерфейсах между PLC и микроконтроллерами или другими системами, где данные отправляются по сети или через протокол, который обрабатывает байты. В данном случае непосредственно работа с байтами может быть удобной и эффективной.
Почему используется запись Bool как Byte?
Протокол передачи: В большинстве коммуникационных протоколов, включая S7, данные передаются в формате байтов. Это связано с тем, что в низкоуровневых системах и сетевых протоколах все данные представляют собой последовательности байтов. Чтобы передать булевые значения, их обычно представляют как 1 (истина) и 0 (ложь).
Экономия места: Каждый бит в байте можно использовать для хранения булевых значений. Таким образом, не тратить отдельные байты на каждое булевое значение, вместо этого можно упаковывать несколько булевых значений в одном байте.
Представление данных: Некоторые PLC работают с битами, и бинарное представление (0 и 1) непосредственно сопоставимо с состояниями "включён" и "выключен", что делает интерпретацию данных гораздо проще.
Альтернативный способ записи
Если вы хотите записывать каждое булевое значение в виде битов и используете один байт для нескольких значений, можете групировать несколько булевых значений в один байт. Далее, вот как можно реализовать это:
csharp
private void WritePLCData()
{
try
{
// Предположим, что у нас 20 байт.
byte[] db1Data = new byte[20]; // Для всех значений (логические и аналоговые)
// Упаковка контрольных состояний в байт.
// Используем один байт для упаковки нескольких булевых значений.
db1Data[0] = 0; // Это будет наш первый байт, в который мы будем записывать булевые значения
db1Data[0] |= (byte)(P1_Open ? 1 : 0); // Бит 0
db1Data[0] |= (byte)((P1_Close ? 1 : 0) << 1); // Бит 1
db1Data[0] |= (byte)((P2_Open ? 1 : 0) << 2); // Бит 2
db1Data[0] |= (byte)((P2_Close ? 1 : 0) << 3); // Бит 3
db1Data[0] |= (byte)((P3_Open ? 1 : 0) << 4); // Бит 4
db1Data[0] |= (byte)((P3_Close ? 1 : 0) << 5); // Бит 5
db1Data[0] |= (byte)((P4_Open ? 1 : 0) << 6); // Бит 6
db1Data[0] |= (byte)((P4_Close ? 1 : 0) << 7); // Бит 7
// Переходим к следующему байту для других контрольных значений
db1Data[1] = 0; // Второй байт
db1Data[1] |= (byte)(P5_Open ? 1 : 0);
db1Data[1] |= (byte)((P5_Close ? 1 : 0) << 1);
db1Data[1] |= (byte)((P6_Open ? 1 : 0) << 2);
db1Data[1] |= (byte)((P6_Close ? 1 : 0) << 3);
db1Data[1] |= (byte)((P7_Open ? 1 : 0) << 4);
db1Data[1] |= (byte)((P7_Close ? 1 : 0) << 5);
db1Data[1] |= (byte)(Shield_Open ? 1 : 0 << 6);
db1Data[1] |= (byte)(Shield_Close ? 1 : 0 << 7);
// Запись значений Pos_Vert и Pos_Horizontal как DInt
BitConverter.GetBytes(Convert.ToInt32(VerticalRotateCurrentAngle)).CopyTo(db1Data, 2); // С 2-го байта
BitConverter.GetBytes(Convert.ToInt32(HorizontalRotateCurrentAngle)).CopyTo(db1Data, 6); // С 6-го байта
// Запись данных в DB1
plc.WriteBytes(DataType.DataBlock, 1, 0, db1Data);
}
catch (Exception ex)
{
Debug.LogError($"PLC Write Error: {ex.Message}");
}
}
Важные моменты:
Упаковка логических значений: Теперь каждое булевое значение упаковывается в отдельный бит внутри байта.
Группировка: Вы можете группировать логические значения в байты для более эффективной передачи данных.
Проверка данных на PLC: Не забудьте проверить, как PLС ожидает получать данные и в каком формате, чтобы гарантировать соответствие.
Эти изменения могут сделать код более понятным и оптимальным для передачи через сетевые протоколы, но важно следить за тем, чтобы PLC правильно интерпретировал сообщения.
Конечно! Давайте перепишем метод ReadPLCData так, чтобы он считывал булевые значения из блока данных в формате битов. Это позволяет более эффективно использовать пространство, поскольку мы можем хранить несколько булевых значений в одном байте.
Для этого нам нужно сначала считать соответствующий байт из блока данных, а затем использовать биты в этом байте для установки значений булевых переменных.
Вот обновлённый метод ReadPLCData с учетом работы с битами:
Считывание байтов: Мы читаем 20 байт из DB2 и сохраняем их в массив db2Data.
Извлечение битов: Для каждого булевого значения мы используем логическое И (&) с соответствующим значением бита (например, 0x01 для первого бита, 0x02 для второго и так далее) и проверяем, установлено ли значение (то есть не равно ли нулю).
Этот метод эффективно извлекает булевые значения из байтов, и теперь у вас есть возможность использовать пространственный подход к хранению логических значений, что позволяет сэкономить память и, возможно, улучшить производительность.
Проверьте правильность считывания значений согласно вашей логике управления PLC, чтобы убедиться, что всё работает как задумано.