This is the research Title : Alzheimer’s disease detection from optimal…
- User
This is the research Title : Alzheimer’s disease detection from optimal electroencephalogram channels and tunable Q-wavelet transform Authors are Digambar Puri, Sanjay Nalbalwar, Anil Nandgaonkar, Abhay Wagh DOI: 10.11591/ijeecs.v25.i3.pp1420-1428 Below is the note i made from research paper, read both research paper and my notes to make me a complete code for this project that can run using python and on google colab the dataset location is "C:\Users\Windows 10\Dataset\dataset\AD_Data_origanl mat file\Dataset 1" in which in this these are the files
preproctrials01.mat preproctrials02.mat preproctrials03.mat preproctrials04.mat preproctrials05.mat preproctrials06.mat preproctrials07.mat preproctrials08.mat preproctrials09.mat preproctrials10.mat preproctrials11.mat preproctrials12.mat preproctrials13.mat preproctrials14.mat preproctrials15.mat preproctrials16.mat preproctrials17.mat preproctrials18.mat preproctrials19.mat preproctrials20.mat preproctrials21.mat preproctrials22.mat preproctrials23.mat
if i load "preproctrials01.mat" in matlab, workspace opens on right side which has following info: data 1x1 struct
and the in middle i get these info: fsample 256 sampleinfo [1,1280] trial 1x35 cell time 1x35 cell label 16x1 cell cfg 1x1 structure from which "trial" and "time" is only thing that changes for everyfile, other things like fsample, sampleinfo, label and cfg doesn't change NOTES:
a method to detect the AD patients from NC subjects using a novel approach of channel optimization and TQWT based features extraction. Initially, the number of channels are optimized using Shannon entropy to signal energy ratio. The EEG signals from 10 optimized channels were decomposed into nine different SBs. The four different features are extracted from nine SBs to train and test various classification models. The extracted features from SB7 with EBT produced the highest classification accuracy of 96.20% with ten-fold cross-validation and it outperforms the state of the art methods. Introduction Proposed Method EEG dataset 12-AD and 11-NC subjects 16-electrods used named, Fz, Cz, Pz, O1, O2, F3, F8, Fp1, Fp2, F4, F7, C3, C4, T4, T3, T6 and T5 captured eye-closed and resting state during day time in multiple sessions five seconds, 256Hz using 12-bit Analog to digital converter Flow diagram 1. EEG Data 2. Channel optimization 1. Subband filtering 2. Shannon Entropy (ShEn) and Signal Energy (E) 3. ShEn by E ratio calculation 4. Backward Elimination 3. TQWT decomposition 4. feature extraction 1. Tsallis entropy (TsEn) 2. Renyi's entropy (ReEn) 3. Katz;s fractal dimension (KFD) 4. Kurtosis (K) 5. Classification 1. AD or 2. NC Channel selection method desire for optimal channel selection to reduce data redundancy and computational complexity from each channel is filtered into delta (δ: 0.5-4 Hz), theta (θ: 4-8 Hz), alpha (α: 8-13 Hz), and beta (β: 13-30 Hz) EEG SBs SEREN is measured S E S E R=\frac{S h E n}{E}=\frac{-\sum P_m \log \left(P_m\right)}{\sum s(n)^2} ; Pm = probability of datum being in bin & s(n) = samples in EEG data sequence Out of 16 EEG channels only ten most significant channels ( Cz, Pz, O1, O2, Fp1, Fp2, C3, T4, T3 and T5) were selected for feature extraction followed by classification Pseudo code for channel optimization 1: Filter EEG signal into EEG SBs. Find ShEn/E ratio. Get max(ACC) = T H, channel count j = 16; 2: while (1 ≤ i ≤ 16) do 3: Remove Cj 4: if ShEn/E ≥ TH then 5: Reject the channel Ci; 6: j ← j − 1; 7: else 8: j ← j − 1, Don’t reject Cj 9: end if 10: i ← i + 1; 11: end while 12: The value of j gives the number of optimal channels. Tunable Q-walelet transform TQWT consits of two variable parameters named Redundancy (R) and quality factor (Q), which can be changed to get required time-frequency resolution TQWT consist filter filter bank with two channels; 1st: Lowpass filer (LPS) H_0(w)=\left{\begin{array}{cc} 1, & |w| \leq(1-\beta) \pi \ \Theta\left(\frac{w+(\beta-1) \pi}{\alpha+\beta-1}\right), & (1-\beta) \pi<|w|<\alpha \pi \ 0 & \alpha \pi \leq|w| \leq \pi \end{array}\right. and 2nd : Highpass filter (HPF) H_1(w)=\left{\begin{array}{cc} 0, & |w| \leq(1-\beta) \pi \ \Theta\left(\frac{\alpha \pi-w}{\alpha+\beta-1}\right), & (1-\beta) \pi<|w|<\alpha \pi \ 1 & \alpha \pi \leq|w| \leq \pi \end{array}\right. expression for Θ(w) is \Theta(w)=\frac{1}{2}[\cos (w)+1][2-\cos (w)]^{0.5},|w| \leq \pi α and β are scaling parameter of LPF & HPF in range of 0 to 1, α+β>1 Q is depending on SB central frequency F0 and Bandwith Bw; Q=F0/Bw β=2/Q+1 and α=1-β/R In decomposition of EEG using TQWT, authors selected parameters of Q=1, R=3 and J=8 after doing some testing Thus 9 different SBs have been evaluated Feature extraction decomposed in 9 different SBs using TQWT feature 1:TsEn measure has proved to be more robus compared to ShEn which detects spikes, bursts and EEG rhythms T s E n=\frac{1}{q-1}\left(1-\sum_{m=1}^N p_m(v)^q\right) where, q>0, Pm are the probabilities of a datum being in bin N is number of samples in EEG feature 2:ReEn is used for epilepsy, drowsiness etc. Generalized the Hartley entropy, collision entropy, ShEn and min-entropy. Utilised to calculate entanglement \operatorname{ReEn}=\frac{1}{q-1}\left(\log \sum_{m=1}^N p_m(v)^q\right) where, q is parameter value between 0 and 1. N is maximum number of segments in EEG feature 3: KFD is most important type of fractal dimension used to measure complexity. which can be defined as the sum and average of Euclidean distances between successive points of a sample D and b respectively, are measured also teh maximum distance between the first point and other point of the sample left K F D=\frac{\log (D / b)}{\log (l / a)}=\frac{\log (m)}{\log (m)+\log (l / b)} where, m=D/a feature 4: Kurtosis (K) can be expressed as a measure of how outlier-prone a distribution is K=\frac{E(x-\mu)^4}{\sigma^4} where, µ is mean and σ is standard deviation (STD) Classification to detect the AD from NC using KFD, TsEn, ReEn and K feature setthe author used various classifiers namely fine-DT, cubic-SVM, cosine-KNN, wide-ANN and EBT. TQWT based time-frequency method has been used to overcome the limitations of wavelet and FFT. TQWT parameters Q=1, R=3, J=8 are selected to decompose EEG to produce nine SBs features are calculated from nine SBs. The statistical analysis of extracted feature sets has been performed using KW test, which provides the value of "p" probability; if value of p<0.05 are significant to discriminate the different classes. The p probability values for KFD, TsEn, ReEn andK features have shown in Table Table: Summary of p-values calculated using KW test for AD vs NC classes in each SB Subbands KFD TsEn ReEn K SB1 1.01×10^−33 3.53×10^−118 3.37×10^−45 4.62×10^−14 SB2 1.94×10^−15 4.44×10^−122 9.82×10^−64 9.34×10^−21 SB3 9.93×10^−17 4.15×10^−87 6.58×10^−42 8.75×10^−7 SB4 5.29×10^−15 5.08×10^−62 1.70×10^−48 1.23×10^−5 SB5 1.15×10^−110 8.03×10^−29 7.49×10^−16 4.25×10^−8 SB6 1.00×10^−139 3.61×10^−4 5.55×10^−24 1.08×10^−17 SB7 2.01×10^−143 4.21×10^−6 6.48×10^−15 4.49×10^−11 SB8 8.92×10^−127 9.43×10^−8 5.45×10^−17 8.89×10^−5 SB9 1.07×10^−150 1.94×10^−4 9.02×10^−14 3.94×10^−12 all features are having p < 0.05. Hence, all features were selected for further analysis The five different classifiers, namely Fine-DT, Cubic-SVM, KNN, Wide-ANN, and EBT are trained and tested using the above evaluated feature sets. The model parameters and kernel functions for each classifier have been adopted from various iterations. The ten number of splits in Fine-DT are selected. In Cubic-SVM, the kernel was chosen as automatic. The parameter values such as k and number of splits are 50, and 10 were selected. The learning rate of 0.1 and the activation function as ReLu have been selected to achieve maximum accuracy. In ANN, the layers and iteration limit were two and 500, respectively. Table 2 demonstrates the classification accuracy obtained from various classifiers for each SB. The EBT performs best out of all five models with a classification accuracy of 96.2% using SB7 feature sets. After EBT, the KNN performs better and provides an accuracy of 94.1% for SB7. The highest accuracy obtained from the DT model is 91.9% for SB7, and worst is 87% for SB9. In the case of SVM, higher ACC obtained is 93.8% for SB7 and lower ACC is 84.8% for SB9. DT and NN perform poor compared to other classification models. The EBT performs worst for the feature sets from SB9. Out of nine SBs, the seventh SB have the highest discriminating ability compared to other SBs. The performance evaluation parameters ACC, SEN, SPE, precision, F1-score, MCC, and κ-value for classifiers with SB7 have presented in Table The classification accuracy (%) for each SB evaluated by variety of classifiers with 10-fold cross validation technique when Q = 1, r = 3, and J = 8 Classifier SB1 SB2 SB3 SB4 SB5 SB6 SB7 SB8 SB9 Fine-DT 89.3 88.1 89.1 90.5 91.1 91.7 91.9 90.3 87.0 Cubic-SVM 93.7 91.9 93.1 92.8 93.5 93.4 93.8 92.5 84.8 Cosine-KNN 93.1 92.8 92.6 92.5 91.9 92.5 94.1 91.7 83.0 EBT 93.2 91.7 91.4 92.2 93.1 93.1 96.2 93.7 85.5 Wide-ANN 92.3 91.7 92.3 92.8 92.9 91.9 91.7 91.6 84.5 From Table 3, it is observed that EBT has the highest SEN 90.49% and SPE 97.5%. The worst SEN and SPE noted by DT, i.e. 86.6% and 92.5% respectively. The precision, F1-score, MCC, and κ values for EBT are 93.24%, 94.84%, 86.73%, and 80.64% respectively The comparison of the proposed method with state of the art techniques which have used same EEG datasets have been shown in Table 4. Abasolo ´ et al. has developed various entropy based technique to detect the AD from NC from EEG signals and obtained maximum ACC of 90.91% for ApEn and AMI [6], [7], [9], [10]. Escuredo et al. proposed a MSE based method to overcome the limitations of ApEn and achieved the ACC of 90.91%. Afterwords, Simons et al. used QSE and FuzzyEn to detect AD [8], [11]. The FuzzyEn provided the 86.36% classification ACC. It must be noted that the above mentioned methods used only time domain complexity features. The proposed method achieved the 96.20% ACC with TQWT and EBT from SB7. The comparison of proposed method with the recently reported methods which used different EEG datasets have been shown in Table 5. All the methods mentioned in the Table 5 were used wavelet based features to detect the AD from NC. Safi et al. used wavelet based HP features and achieved maximum ACC of 95.79% with SVM among all other studies [14]. In the proposed method, EBT classifier has provided promising results in detecting AD patients from NC subjects using the TQWT based features from the seventh SB. . The extracted features from SB7 with EBT produced the highest classification accuracy of 96.20% with ten-fold cross-validation and it outperforms the state of the art methods
- Assistant