Help me interpret my results for my second report should consist of an application of the time series econometrics learnt in Modules 4-5 to your data. Full submission should consist of a document containing the introduction, literature review, methods and data and preliminary results; the file containing your data and your computer codes. Please present the results (tables, plots, etc. in your report).
USL is United States 12 Month Oil Fund LP.
FUT is Future oil Prices.
Residual standard error: 0.02362 on 3142 degrees of freedom
Multiple R-squared: 0.004243, Adjusted R-squared: 0.003292
F-statistic: 4.463 on 3 and 3142 DF, p-value: 0.003915
Value of test-statistic is: -2.1862 1.627 2.3997
Critical values for test statistics:
1pct 5pct 10pct
tau3 -3.96 -3.41 -3.12
phi2 6.09 4.68 4.03
phi3 8.27 6.25 5.34
Residual standard error: 0.01826 on 3142 degrees of freedom
Multiple R-squared: 0.00253, Adjusted R-squared: 0.001578
F-statistic: 2.657 on 3 and 3142 DF, p-value: 0.04682
Value of test-statistic is: -1.9289 1.4759 1.9049
Critical values for test statistics:
1pct 5pct 10pct
tau3 -3.96 -3.41 -3.12
phi2 6.09 4.68 4.03
phi3 8.27 6.25 5.34
Residual standard error: 0.02362 on 3143 degrees of freedom
Multiple R-squared: 0.003919, Adjusted R-squared: 0.003285
F-statistic: 6.183 on 2 and 3143 DF, p-value: 0.002089
Value of test-statistic is: -1.9434 1.9292
Critical values for test statistics:
1pct 5pct 10pct
tau2 -3.43 -2.86 -2.57
phi1 6.43 4.59 3.78
Residual standard error: 0.01826 on 3143 degrees of freedom
Multiple R-squared: 0.001954, Adjusted R-squared: 0.001319
F-statistic: 3.077 on 2 and 3143 DF, p-value: 0.04622
Value of test-statistic is: -1.4127 1.3068
Critical values for test statistics:
1pct 5pct 10pct
tau2 -3.43 -2.86 -2.57
phi1 6.43 4.59 3.78
Residual standard error: 0.02363 on 3144 degrees of freedom
Multiple R-squared: 0.00278, Adjusted R-squared: 0.002145
F-statistic: 4.382 on 2 and 3144 DF, p-value: 0.01258
Value of test-statistic is: -0.4356
Critical values for test statistics:
1pct 5pct 10pct
tau1 -2.58 -1.95 -1.62
Residual standard error: 0.01827 on 3144 degrees of freedom
Multiple R-squared: 0.001589, Adjusted R-squared: 0.0009537
F-statistic: 2.502 on 2 and 3144 DF, p-value: 0.08212
Value of test-statistic is: -0.9426
Critical values for test statistics:
1pct 5pct 10pct
tau1 -2.58 -1.95 -1.62
Conduct Dickey-Fuller tests on first-difference data
Residual standard error: 0.02362 on 3141 degrees of freedom
Multiple R-squared: 0.5272, Adjusted R-squared: 0.5267
F-statistic: 1167 on 3 and 3141 DF, p-value: < 2.2e-16
Value of test-statistic is: -42.6185 605.4453 908.1679
Critical values for test statistics:
1pct 5pct 10pct
tau3 -3.96 -3.41 -3.12
phi2 6.09 4.68 4.03
phi3 8.27 6.25 5.34
Residual standard error: 0.01827 on 3141 degrees of freedom
Multiple R-squared: 0.5182, Adjusted R-squared: 0.5177
F-statistic: 1126 on 3 and 3141 DF, p-value: < 2.2e-16
Value of test-statistic is: -40.1064 536.1738 804.2607
Critical values for test statistics:
1pct 5pct 10pct
tau3 -3.96 -3.41 -3.12
phi2 6.09 4.68 4.03
phi3 8.27 6.25 5.34
Residual standard error: 0.02361 on 3142 degrees of freedom
Multiple R-squared: 0.5272, Adjusted R-squared: 0.5269
F-statistic: 1752 on 2 and 3142 DF, p-value: < 2.2e-16
Value of test-statistic is: -42.6249 908.4414
Critical values for test statistics:
1pct 5pct 10pct
tau2 -3.43 -2.86 -2.57
phi1 6.43 4.59 3.78
Residual standard error: 0.01827 on 3142 degrees of freedom
Multiple R-squared: 0.5182, Adjusted R-squared: 0.5179
F-statistic: 1690 on 2 and 3142 DF, p-value: < 2.2e-16
Value of test-statistic is: -40.1111 804.4511
Critical values for test statistics:
1pct 5pct 10pct
tau2 -3.43 -2.86 -2.57
phi1 6.43 4.59 3.78
Residual standard error: 0.02361 on 3143 degrees of freedom
Multiple R-squared: 0.5272, Adjusted R-squared: 0.5269
F-statistic: 1752 on 2 and 3143 DF, p-value: < 2.2e-16
Value of test-statistic is: -42.6301
Critical values for test statistics:
1pct 5pct 10pct
tau1 -2.58 -1.95 -1.62
Residual standard error: 0.01827 on 3143 degrees of freedom
Multiple R-squared: 0.5181, Adjusted R-squared: 0.5178
F-statistic: 1690 on 2 and 3143 DF, p-value: < 2.2e-16
Value of test-statistic is: -40.106
Critical values for test statistics:
1pct 5pct 10pct
tau1 -2.58 -1.95 -1.62
Certainly! Interpreting your Augmented Dickey-Fuller (ADF) test results is crucial for understanding the properties of your time series data, specifically whether they are stationary or possess unit roots. Here's a comprehensive interpretation of your results, which you can incorporate into the preliminary results section of your report.
Preliminary Results
1. Data Preparation and Transformation
You analyzed two time series datasets:
USL: United States 12 Month Oil Fund LP
FUT: Future oil Prices
Both datasets were log-transformed to stabilize variance and then differenced to achieve stationarity. The specific steps included:
Log Transformation: Applied to both FUT and USL to obtain log_Fut and log_USL.
First Differencing: Computed to obtain diff_log_Fut and diff_log_USL, addressing potential non-stationarity.
2. Augmented Dickey-Fuller (ADF) Tests
The ADF tests were conducted under three different regression specifications:
With Trend (trend)
With Drift (drift)
No Constant or Trend (none)
These specifications help in determining the presence of a unit root under different assumptions about the data's deterministic components.
2.1. ADF Tests on Log-Transformed Data (Levels)
Null Hypothesis (H₀): The series has a unit root (i.e., it is non-stationary).
Alternative Hypothesis (H₁): The series is stationary.
Specification
log_Fut
log_USL
Trend
-2.1862
-1.9289
Drift
-1.9434
-1.4127
None
-0.4356
-0.9426
Critical Values at 5% Significance Level:
tau3 (Trend): -3.41
tau2 (Drift): -2.86
tau1 (None): -1.95
Interpretation:
log_Fut:
Trend Specification: Test statistic (-2.1862) > critical value (-3.41). Fail to reject H₀.
Drift Specification: Test statistic (-1.9434) > critical value (-2.86). Fail to reject H₀.
None Specification: Test statistic (-0.4356) > critical value (-1.95). Fail to reject H₀.
log_USL:
Trend Specification: Test statistic (-1.9289) > critical value (-3.41). Fail to reject H₀.
Drift Specification: Test statistic (-1.4127) > critical value (-2.86). Fail to reject H₀.
None Specification: Test statistic (-0.9426) > critical value (-1.95). Fail to reject H₀.
Conclusion: Both log_Fut and log_USL exhibit unit roots across all specifications, indicating that they are non-stationary in levels.
2.2. ADF Tests on First-Differenced Data
Null Hypothesis (H₀): The differenced series has a unit root (i.e., it is non-stationary).
Alternative Hypothesis (H₁): The differenced series is stationary.
Specification
diff_log_Fut
diff_log_USL
Trend
-42.6185
-40.1064
Drift
-42.6249
-40.1111
None
-42.6301
-40.1060
Critical Values at 5% Significance Level:
tau3 (Trend): -3.41
tau2 (Drift): -2.86
tau1 (None): -1.95
Interpretation:
diff_log_Fut:
All Specifications: Test statistics (~-42.62) < critical values (-3.41, -2.86, -1.95). Reject H₀.
diff_log_USL:
All Specifications: Test statistics (~-40.11) < critical values (-3.41, -2.86, -1.95). Reject H₀.
Conclusion: Both diff_log_Fut and diff_log_USLdo not possess unit roots under any specification, indicating that they are stationary in first differences.
3. Summary of Findings
Variable
Presence of Unit Root (Levels)
Presence of Unit Root (First Differences)
Integration Order
log_Fut
Yes
No
I(1)
log_USL
Yes
No
I(1)
Integration Order (I(d)): Both series are integrated of order 1, denoted as I(1). This implies that they are non-stationary in levels but become stationary after first differencing.
4. Implications for Econometric Modeling
Non-Stationarity in Levels: Using non-stationary data in regression models can lead to spurious results. Therefore, it's essential to address unit roots before proceeding with further analysis.
Stationarity in First Differences: Since both series are I(1), you can consider models that operate on differenced data, such as ARIMA models for forecasting.
Potential for Cointegration: Given that both series are I(1), there is a possibility that they are cointegrated, meaning a long-term equilibrium relationship exists between them. Testing for cointegration (e.g., using the Johansen test) would be a logical next step in your analysis.
5. Recommendations for Further Analysis
Cointegration Testing: Investigate whether log_Fut and log_USL are cointegrated. If cointegration exists, Vector Error Correction Models (VECM) can be employed to capture both short-term dynamics and long-term relationships.
Model Specification: Depending on the stationarity properties, specify appropriate time series models (e.g., ARIMA, VAR).
Diagnostic Checks: After model estimation, perform diagnostic tests to ensure model adequacy, such as checking for autocorrelation, heteroskedasticity, and normality of residuals.
Economic Interpretation: Align the statistical findings with economic theory to provide meaningful insights into the behavior of oil prices and related financial instruments.
Conclusion
The ADF test results indicate that both log_Fut and log_USL are non-stationary in their level forms but achieve stationarity upon first differencing. This characteristic is fundamental in determining the appropriate econometric models for further analysis, ensuring robust and reliable inference.
Ensure that you include relevant tables and plots in your report to visually represent these findings. For instance, time series plots of the original and differenced data can effectively illustrate the stationarity properties, while tables summarizing the ADF test statistics, critical values, and conclusions will provide clarity to your readers.
If you have any further questions or need assistance with the next steps in your analysis, feel free to ask!