how can i pick other point, can you create a code so i can pick other point in pareto front?
% run_MOEMA_MultiObjective.m
% Comprehensive script to run MOEMA optimization for Smart Building Comfort and Energy Consumption
% Number of decision variables: 3 per period for 48 periods
dim = 144;
% Population size and number of iterations
NPop = 50; % Population size
T = 500; % Number of iterations
% Define lower and upper bounds for each variable
% Each period has T, L, IAQ variables with specific bounds
lb = zeros(1, dim);
ub = zeros(1, dim);
Assistant
User
i dont want a random point. i want point for EC_avg to be 198.567 and the -CI_avg to be -0.997452
Assistant
User
also add the plot for temp,lux and iaq
Assistant
% Define bounds per variable type
% T: Temperature [20, 25.56]
% L: Light [720, 880]
% IAQ: IAQ [700, 880]
% Assign bounds for each variable in the decision vector
for k = 1:48
idx = 3*(k-1) + 1;
lb(idx) = 20; % Temperature lower bound
ub(idx) = 25.56; % Temperature upper bound
% Plot the Pareto front for the best run
figure;
plot(paretoFront(:,1), paretoFront(:,2), 'ro', 'MarkerSize',8, 'LineWidth',1.5);
xlabel('-Average Comfort Index');
ylabel('Average Energy Consumption');
title('Best Pareto Front for Smart Building Optimization using MOEMA');
grid on;
set(gca, 'FontSize', 12);
% First, find the best balanced solution from Pareto front
% Convert -CI_avg back to CI_avg
CI_values = -paretoFront(:,1);
EC_values = paretoFront(:,2);
% Find the solution closest to ideal point (1,0)
distances = sqrt((1-CI_norm).^2 + EC_norm.^2);
[~, best_idx] = min(distances);
% Get the best solution settings
optimized_solution = paretoSet(best_idx, :); % 1x144 vector
% Extract optimized settings for each period
optimized_settings = reshape(optimized_solution, 3, 48)'; % 48x3 matrix: [T, L, IAQ]
% Original settings from dataSH
original_temp = dataSH(:,3); % Temperature in C
original_lux = dataSH(:,4); % lux
original_IAQ = dataSH(:,5); % IAQ
% Optimized settings from the best balanced solution
optimized_temp = optimized_settings(:,1);
optimized_lux = optimized_settings(:,2);
optimized_IAQ = optimized_settings(:,3);
% Desired values
desired_temp = 22.78; % As per cost function
desired_lux = 800; % As per cost function
desired_IAQ = 800; % As per cost function
% Create a time vector for 48 periods
time = dataSH(:,1); % Assuming time instance is from 1 to 48
% Temperature Plot
figure;
plot(time, original_temp, 'b-', 'LineWidth',1.5); hold on;
plot(time, optimized_temp, 'r--', 'LineWidth',1.5);
yline(desired_temp, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('Temperature (°C)');
title('Temperature Before and After Optimization (Best Balanced Solution)');
legend('Original', 'Optimized', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [100, 100, 800, 400]); % Set window size
% Light Level Plot
figure;
plot(time, original_lux, 'b-', 'LineWidth',1.5); hold on;
plot(time, optimized_lux, 'r--', 'LineWidth',1.5);
yline(desired_lux, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('Light Level (lux)');
title('LUX Before and After Optimization (Best Balanced Solution)');
legend('Original', 'Optimized', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [200, 200, 800, 400]); % Set window size
% IAQ Plot
figure;
plot(time, original_IAQ, 'b-', 'LineWidth',1.5); hold on;
plot(time, optimized_IAQ, 'r--', 'LineWidth',1.5);
yline(desired_IAQ, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('IAQ');
title('IAQ Before and After Optimization (Best Balanced Solution)');
legend('Original', 'Optimized', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [300, 300, 800, 400]); % Set window size
% Display metrics for the best balanced solution
fprintf('\nBest Balanced Solution Metrics:\n');
fprintf('Comfort Index: %.5f\n', CI_values(best_idx));
fprintf('Energy Consumption: %.2f\n', EC_values(best_idx));
% ------------------ plot for the best pareto ------------------
figure;
% Plot all Pareto front points in red
plot(paretoFront(:,1), paretoFront(:,2), 'ro', 'MarkerSize',8, 'LineWidth',1.5);
hold on;
% Plot the balanced solution point in green
plot(paretoFront(best_idx,1), paretoFront(best_idx,2), 'go', 'MarkerSize',12, 'LineWidth',2, 'MarkerFaceColor','g');
xlabel('-Average Comfort Index');
ylabel('Average Energy Consumption');
title('Pareto Front for Smart Building Optimization using MOEMA');
legend('Pareto Front', 'Balanced Solution', 'Location', 'best');
grid on;
set(gca, 'FontSize', 12);
% ---------- Multi-Objective Cost Function ----------
function objectives = multi_objective_cost_function(X, dataSH)
% MULTI_OBJECTIVE_COST_FUNCTION Evaluates user comfort and energy consumption.
%
% This function is designed for multi-objective optimization with two objectives:
% 1. Maximize User Comfort (to be minimized as -CI_avg)
% 2. Minimize Energy Consumption (EC_avg)
%
% Inputs:
% X - A vector of decision variables for 48 periods, structured as:
% [T1, L1, IAQ1, T2, L2, IAQ2, ..., T48, L48, IAQ48]
% dataSH - A 48x5 matrix where:
% dataSH(:,3) = Temperature coefficients (Tc)
% dataSH(:,4) = Light coefficients (Lc)
% dataSH(:,5) = IAQ coefficients (IAQc)
%
% Output:
% objectives - A 2-element vector:
% [ -Average Comfort Index, Average Energy Consumption ]
% Ensure that X has the correct length
if length(X) ~= 144
error('Decision vector X must have 144 elements (3 variables per 48 periods).');
end
% Weight coefficients for comfort components
p1 = 1/3; % Temperature Weight
p2 = 1/3; % Light Weight
p3 = 1/3; % IAQ Weight
% Desired setpoints for comfort
Td = 22.78; % Desired Temperature (°C)
Ld = 800; % Desired Light Level (lux)
Id = 800; % Desired IAQ Level
% Energy consumption weights
pT = 9; % Temperature Energy Consumption Weight
pL = 1; % Light Energy Consumption Weight
pI = 1; % IAQ Energy Consumption Weight
% Extract coefficients from dataSH for all 48 periods
Tc = dataSH(:,3)'; % Temperature coefficients (1x48 vector)
Lc = dataSH(:,4)'; % Light coefficients (1x48 vector)
Ic = dataSH(:,5)'; % IAQ coefficients (1x48 vector)
% Initialize vectors to store metrics for each period
CI = zeros(48,1); % Comfort Index for each period
EC = zeros(48,1); % Energy Consumption for each period
% Loop through each of the 48 periods to compute metrics
for k = 1:48
% Extract decision variables for period k
Tk = X(3*k-2); % Temperature setting
Lk = X(3*k-1); % Light setting
Ik = X(3*k); % IAQ setting
% --- Calculate Comfort Index Components ---
Ti = 1 - ((Tk - Td) / Tc(k))^2;
Li = 1 - ((Lk - Ld) / Lc(k))^2;
Ii = 1 - ((Ik - Id) / Ic(k))^2;
CI(k) = p1 * Ti + p2 * Li + p3 * Ii;
% --- Calculate Energy Consumption ---
ET = pT * abs(Tk - Tc(k));
EL = pL * abs(Lk - Lc(k));
EI = pI * abs(Ik - Ic(k));
EC(k) = ET + EL + EI;
end
% --- Aggregate Metrics Over All Periods ---
CI_avg = mean(CI); % Average Comfort Index
EC_avg = mean(EC); % Average Energy Consumption
% --- Prepare Objectives for Multi-Objective Optimization ---
% Objective 1: Maximize User Comfort -> Minimize (-CI_avg)
% Objective 2: Minimize Energy Consumption -> Minimize (EC_avg)
objectives = [-CI_avg, EC_avg];
% Generation of initial population
pop = initialization(NPop, dim, ub, lb);
pop_dad = pop(1:NPop/2, :); % Eqn (1) in the paper
pop_mum = pop(NPop/2+1:end, :); % Eqn (2) in the paper
% Evaluation of objective function for initialization
obj_dad = evaluate_population(pop_dad, FITNESSFCN);
obj_mum = evaluate_population(pop_mum, FITNESSFCN);
obj = [obj_dad; obj_mum];
for k = 1:NPop/2
% Mating process
Imates = 1 + (var(k1x(k, :)) - var(k2x(k, :))); % Eqn (4) in the paper
p = randn(1, dim); % Eqn (6) in the paper
r = levy_flights(1, dim); % Using Levy flights
if Imates >= 0 % Upper part of Eqn (5) in the paper
temp1 = p .* k1x(k, :);
temp2 = (1-p) .* k2x(k, :);
pop_child = temp1 + temp2;
else % Lower part of Eqn (5) in the paper
temp1 = p .* k2x(k, :);
temp2 = (1-p) .* k1x(k, :);
pop_child = temp1 + temp2;
end
% Enhanced Impact of best environment (using random non-dominated solution)
if ~isempty(archive.pop)
best_pop = archive.pop(randi(size(archive.pop, 1)), :);
K = rand(1, dim) < 0.2; % Eqn (8) in the paper
pop_child = best_pop .* (1-K) + pop_child .* K; % Eqn (7) in the paper
end
% Mutation operator
if rand() < 0.1
% Special handling for x1
if rand() < 0.5
pop_child(1) = pop_child(1) + randn() * 0.1;
pop_child(1) = max(0, min(1, pop_child(1)));
end
% Regular mutation for other variables
mutation_idx = rand(1, dim-1) < 0.1;
pop_child(2:end) = pop_child(2:end) + mutation_idx .* randn(1, dim-1) * 0.1;
end
% Bounding of the solution
pop_child = max(min(ub, pop_child), lb);
% Evaluate child
obj_child = FITNESSFCN(pop_child);
% Update population using non-dominated sorting
[pop_dad, obj_dad] = update_population(pop_dad, obj_dad, pop_child, obj_child, k1(k));
[pop_mum, obj_mum] = update_population(pop_mum, obj_mum, pop_child, obj_child, k2(k));
% Exploration process with levy flight
if rand() < 0.9
if ~isempty(archive.pop)
temp1 = archive.pop(randi(size(archive.pop, 1)), :);
pop_child = levy_flights(1, dim) .* temp1; % Exploring with Levy flights
pop_child = max(min(ub, pop_child), lb);
obj_child = FITNESSFCN(pop_child);
% Update population using non-dominated sorting
[pop_dad, obj_dad] = update_population(pop_dad, obj_dad, pop_child, obj_child, randi(NPop/2));
[pop_mum, obj_mum] = update_population(pop_mum, obj_mum, pop_child, obj_child, randi(NPop/2));
end
end
end
% Combine updated pool dad and mum
pop = [pop_dad; pop_mum];
obj = [obj_dad; obj_mum];
% Update archive
archive = update_archive(archive.pop, archive.obj, pop, obj);
% Record the history at each iteration
fitness_history(:, gen, :) = obj;
position_history(:, gen, :) = pop;
% Update Trajectories (using a random non-dominated solution)
if ~isempty(archive.pop)
Trajectories(:, gen) = archive.pop(randi(size(archive.pop, 1)), :)';
end
% Display progress every 10 iterations
if mod(gen, 50) == 0
disp(['Iteration #', num2str(gen), ' completed. Archive size: ', num2str(size(archive.pop, 1))]);
end
end
% Return Pareto front and Pareto set
paretoFront = archive.obj;
paretoSet = archive.pop;
% Calculate spacing metric
spacing = spacing_metric(paretoFront);
end
% ---------- Spacing Metric Function ----------
function spacing = spacing_metric(obtained_pf)
if size(obtained_pf, 1) < 2
spacing = Inf;
return;
end
n = size(obtained_pf, 1);
d = zeros(n, 1);
% Calculate di for each solution
for i = 1:n
% Calculate distances to all other solutions
min_dist = Inf;
for j = 1:n
if i ~= j
% Calculate |f1(x) - f1(x')| + |f2(x) - f2(x')|
dist = abs(obtained_pf(i,1) - obtained_pf(j,1)) + ...
abs(obtained_pf(i,2) - obtained_pf(j,2));
min_dist = min(min_dist, dist);
end
end
d(i) = min_dist;
end
% Calculate mean of distances
d_bar = mean(d);
% Calculate spacing metric SP
spacing = sqrt(sum((d_bar - d).^2) / (n - 1));
end
% Helper Functions
function pop = initialization(NPop, dim, ub, lb)
pop = rand(NPop, dim) .* (ub - lb) + lb;
end
function obj = evaluate_population(pop, FITNESSFCN)
obj = zeros(size(pop, 1), 2); % Assuming 2 objectives
for i = 1:size(pop, 1)
obj(i, :) = FITNESSFCN(pop(i, :));
end
end
function [pop, obj] = update_population(pop, obj, child, child_obj, index)
if dominates(child_obj, obj(index, :))
pop(index, :) = child;
obj(index, :) = child_obj;
elseif ~dominates(obj(index, :), child_obj)
if rand() < 0.5
pop(index, :) = child;
obj(index, :) = child_obj;
end
end
end
for i = 1:n_solutions
for j = i+1:n_solutions
if dominates(objectives(i, :), objectives(j, :))
is_dominated(j) = true;
domination_count(i) = domination_count(i) + 1;
elseif dominates(objectives(j, :), objectives(i, :))
is_dominated(i) = true;
domination_count(j) = domination_count(j) + 1;
end
end
end
end
function result = dominates(obj1, obj2)
result = all(obj1 <= obj2) && any(obj1 < obj2);
end
function steps = levy_flights(n, dim, beta)
% Generates n Levy flight steps in dim dimensions based on Mantegna's algorithm
if nargin < 3
beta = 1.5;
end
sigma_u = (gamma(1 + beta) * sin(pi * beta / 2) / ...
(gamma((1 + beta) / 2) * beta * 2^((beta - 1) / 2)))^(1/beta);
u = random('Normal', 0, sigma_u, n, dim);
v = random('Normal', 0, 1, n, dim);
steps = u ./ abs(v).^(1 / beta);
end
To select a different point on the Pareto front using the provided MATLAB code, you can make a few modifications to the script. Here’s what you can do:
Randomly Select Another Point: Instead of choosing the best balanced solution, you can select another point based on a custom criterion or randomly. The code below demonstrates how to select a random point from the Pareto front.
Modify the Plot and Analyze: Adjustments have been made to appropriately highlight the chosen point on the Pareto front.
Below is a modified code snippet that implements this functionality:
% Plot the Pareto front for the best run
figure;
plot(paretoFront(:,1), paretoFront(:,2), 'ro', 'MarkerSize',8, 'LineWidth',1.5);
xlabel('-Average Comfort Index');
ylabel('Average Energy Consumption');
title('Pareto Front for Smart Building Optimization using MOEMA');
grid on;
set(gca, 'FontSize', 12);
% Select a random point from the Pareto front (other than best balanced)
num_points = size(paretoFront, 1);
random_idx = randi([1, num_points]);
while random_idx == best_idx
random_idx = randi([1, num_points]);
end
% Get the randomly chosen solution settings
random_solution = paretoSet(random_idx, :); % 1x144 vector
% Extract settings for each period
random_settings = reshape(random_solution, 3, 48)'; % 48x3 matrix: [T, L, IAQ]
% Plot the random solution point in a different color (e.g., blue)
hold on;
plot(paretoFront(random_idx, 1), paretoFront(random_idx, 2), 'bo', 'MarkerSize',12, 'LineWidth',2, 'MarkerFaceColor','b');
legend('Pareto Front', 'Balanced Solution', 'Random Solution', 'Location', 'best');
% Display metrics for the randomly chosen solution
fprintf('\nRandom Solution Metrics:\n');
fprintf('Comfort Index: %.5f\n', -paretoFront(random_idx, 1));
fprintf('Energy Consumption: %.2f\n', paretoFront(random_idx, 2));
% You can similarly plot the settings as done for the best balanced solution
% by using the extracted `random_settings`.
Key Steps Explained:
Random Selection: A point is randomly selected from the Pareto front, excluding the best-balanced point to ensure diversity.
Plotting: The selected point is plotted on the Pareto front using a distinct color and labeled appropriately.
Analysis: The comfort index and energy consumption metrics of the randomly selected point are computed and displayed.
Using this approach, you can analyze other points on the Pareto front and study different trade-offs between comfort and energy consumption as per the optimization results.
To select a specific point on the Pareto front based on given values for EC_avg and -CI_avg, you can modify the code to search for the point closest to these target values. Here's how you can implement this in your MATLAB script:
Steps:
Identify the Target Values:
EC_avg_target = 198.567
CI_avg_target = -0.997452
Find the Closest Point:
Calculate the Euclidean distance between each point on the Pareto front and the target values.
Select the point with the smallest distance.
Modify the Plot and Analysis:
Highlight this specific point on the Pareto plot and print its metrics.
Here’s how you can modify your script to accomplish this:
% Define target values
EC_avg_target = 198.567;
CI_avg_target = -0.997452;
% Calculate distances from every point on the Pareto Front to the target values
distances_to_target = sqrt((paretoFront(:, 1) - CI_avg_target).^2 + (paretoFront(:, 2) - EC_avg_target).^2);
% Find the index of the point closest to the target values
[~, target_idx] = min(distances_to_target);
% Get the solution settings closest to the target
target_solution = paretoSet(target_idx, :); % 1x144 vector
% Extract settings for each period
target_settings = reshape(target_solution, 3, 48)'; % 48x3 matrix: [T, L, IAQ]
% Plot the Pareto front
figure;
plot(paretoFront(:,1), paretoFront(:,2), 'ro', 'MarkerSize',8, 'LineWidth',1.5);
hold on;
% Highlight the target point in a different color (e.g., blue)
plot(paretoFront(target_idx, 1), paretoFront(target_idx, 2), 'bo', 'MarkerSize',12, 'LineWidth',2, 'MarkerFaceColor','b');
xlabel('-Average Comfort Index');
ylabel('Average Energy Consumption');
title('Pareto Front for Smart Building Optimization using MOEMA');
legend('Pareto Front', 'Target Solution', 'Location', 'best');
grid on;
set(gca, 'FontSize', 12);
% Display metrics for the target solution
fprintf('\nTarget Solution Metrics:\n');
fprintf('Comfort Index: %.5f\n', -paretoFront(target_idx, 1));
fprintf('Energy Consumption: %.2f\n', paretoFront(target_idx, 2));
% You can similarly plot the settings as done for the best balanced solution
% by using the extracted `target_settings`.
Key Points:
Closest Point Calculation: This approach uses the Euclidean distance to find the point on the Pareto front closest to the specified EC_avg and -CI_avg values.
Highlighting: The identified point is plotted prominently on the Pareto plot.
You can then analyze the extracted settings from target_settings in a similar manner as was done for the best balanced solution or any other solution of interest.
To include plots for temperature, lux, and IAQ settings of the solution closest to your target values on the Pareto front, you can follow these steps. This involves extracting the solution values and plotting them alongside the original data for comparison.
Here’s how you can modify your script to include these plots:
% Assuming the code for identifying the target solution is already executed
% Original settings from dataSH
original_temp = dataSH(:,3); % Temperature in °C
original_lux = dataSH(:,4); % lux
original_IAQ = dataSH(:,5); % IAQ
% Settings from the target solution
target_temp = target_settings(:,1);
target_lux = target_settings(:,2);
target_IAQ = target_settings(:,3);
% Desired values
desired_temp = 22.78; % As per cost function
desired_lux = 800; % As per cost function
desired_IAQ = 800; % As per cost function
% Create a time vector for 48 periods
time = dataSH(:,1); % Assuming time instance is from 1 to 48
% Temperature Plot
figure;
plot(time, original_temp, 'b-', 'LineWidth',1.5); hold on;
plot(time, target_temp, 'r--', 'LineWidth',1.5);
yline(desired_temp, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('Temperature (°C)');
title('Temperature Before and After Optimization (Target Solution)');
legend('Original', 'Target', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [100, 100, 800, 400]);
% Light Level Plot
figure;
plot(time, original_lux, 'b-', 'LineWidth',1.5); hold on;
plot(time, target_lux, 'r--', 'LineWidth',1.5);
yline(desired_lux, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('Light Level (lux)');
title('LUX Before and After Optimization (Target Solution)');
legend('Original', 'Target', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [200, 200, 800, 400]);
% IAQ Plot
figure;
plot(time, original_IAQ, 'b-', 'LineWidth',1.5); hold on;
plot(time, target_IAQ, 'r--', 'LineWidth',1.5);
yline(desired_IAQ, 'g:', 'LineWidth',1.5);
xlabel('Time Instance');
ylabel('IAQ');
title('IAQ Before and After Optimization (Target Solution)');
legend('Original', 'Target', 'Desired', 'Location', 'best');
grid on;
set(gcf, 'Position', [300, 300, 800, 400]);
Explanation:
Temperature, Lux, and IAQ Plots: The plotting logic is similar to the best balanced solution. The plots compare the original settings from dataSH with the optimized settings extracted from target_settings for temperature, lux, and IAQ over the 48 time periods.
Consistency Across Plots: All plots are formatted to show the original, target (optimized) settings, and the desired values to easily observe improvements and adherence to desired setpoints.
These plots will help you visualize how close the chosen point's variable settings are to the original data and the desired setpoints, giving insight into the effectiveness of the chosen solution from the Pareto front.