§ Can differentiate storage into:
• volatile storage: loses contents when power is switched off
• non-volatile storage:
§ Contents persist even when power is switched off.
§ Includes secondary and tertiary storage, as well as batter-backed
up main-memory.
§ Factors affecting choice of storage media include
• Speed with which data can be accessed
• Cost per unit of data
• Reliability
§ primary storage: Fastest media but volatile (cache, main memory).
§ secondary storage: next level in hierarchy, non-volatile, moderately fast
access time
• Also called on-line storage
• E.g., flash memory, magnetic disks
§ tertiary storage: lowest level in hierarchy, non-volatile, slow access time
• also called off-line storage and used for archival storage
• e.g., magnetic tape, optical storage
• Magnetic tape
§ Sequential access, 1 to 12 TB capacity
§ A few drives with many tapes
§ Juke boxes with petabytes (1000’s of TB) of storage
§ Disk interface standards families
• SATA (Serial ATA)
§ SATA 3 supports data transfer speeds of up to 6 gigabits/sec
• SAS (Serial Attached SCSI)
§ SAS Version 3 supports 12 gigabits/sec
• NVMe (Non-Volatile Memory Express) interface
§ Works with PCIe connectors to support lower latency and higher
transfer rates
§ Supports data transfer rates of up to 24 gigabits/sec
§ Disks usually connected directly to computer system
§ In Storage Area Networks (SAN), a large number of disks are connected
by a high-speed network to a number of servers
§ In Network Attached Storage (NAS) networked storage provides a file
system interface using networked file system protocol, instead of
providing a disk system interface
§ Read-write head
§ Surface of platter divided into circular tracks
• Over 50K-100K tracks per platter on typical hard disks
§ Each track is divided into sectors.
• A sector is the smallest unit of data that can be read or written.
• Sector size typically 512 bytes
• Typical sectors per track: 500 to 1000 (on inner tracks) to 1000 to
2000 (on outer tracks)
§ To read/write a sector
• disk arm swings to position head on right track
• platter spins continually; data is read/written as sector passes under
head
Assistant
§ Head-disk assemblies
• multiple disk platters on a single spindle (1 to 5 usually)
• one head per platter, mounted on a common arm.
§ Cylinder i consists of i
§ Disk controller – interfaces between the computer system and the disk
drive hardware.
• accepts high-level commands to read or write a sector
• initiates actions such as moving the disk arm to the right track and
actually reading or writing the data
• Computes and attaches checksums to each sector to verify that
data is read back correctly
§ If data is corrupted, with very high probability stored checksum
won’t match recomputed checksum
• Ensures successful writing by reading back sector after writing it
• Performs remapping of bad sectors
§ Access time – the time it takes from when a read or write request is
issued to when data transfer begins. Consists of:
• Seek time – time it takes to reposition the arm over the correct track.
§ Average seek time is 1/2 the worst case seek time.
• Would be 1/3 if all tracks had the same number of sectors, and
we ignore the time to start and stop arm movement
§ 4 to 10 milliseconds on typical disks
• Rotational latency – time it takes for the sector to be accessed to
appear under the head.
§ 4 to 11 milliseconds on typical disks (5400 to 15000 r.p.m.)
§ Average latency is 1/2 of the above latency.
• Overall latency is 5 to 20 msec depending on disk model
§ Data-transfer rate – the rate at which data can be retrieved from or stored
to the disk.
• 25 to 200 MB per second max rate, lower for inner tracks
§ Disk block is a logical unit for storage allocation and retrieval
• 4 to 16 kilobytes typically
§ Smaller blocks: more transfers from disk
§ Larger blocks: more space wasted due to partially filled blocks
§ Sequential access pattern
• Successive requests are for successive disk blocks
• Disk seek required only for first block
§ Random access pattern
• Successive requests are for blocks that can be anywhere on disk
• Each access requires a seek
• Transfer rates are low since a lot of time is wasted in seeks
§ I/O operations per second (IOPS)
• Number of random block reads that a disk can support per second
• 50 to 200 IOPS on current generation magnetic disks
§ Mean time to failure (MTTF) – the average time the disk is expected to
run continuously without any failure.
• Typically 3 to 5 years
• Probability of failure of new disks is quite low, corresponding to a
“theoretical MTTF” of 500,000 to 1,200,000 hours for a new disk
§ E.g., an MTTF of 1,200,000 hours for a new disk means that given
1000 relatively new disks, on an average one will fail every 1200
hours
§ RAID: Redundant Arrays of Independent Disks
• disk organization techniques that manage a large numbers of disks,
providing a view of a single disk of
§ high capacity and high speed by using multiple disks in parallel,
§ high reliability by storing data redundantly, so that data can be
recovered even if a disk fails
§ The chance that some disk out of a set of N disks will fail is much higher
than the chance that a specific single disk will fail.
• E.g., a system with 100 disks, each with MTTF of 100,000 hours
(approx. 11 years), will have a system MTTF of 1000 hours (approx.
41 days)
• Techniques for using redundancy to avoid data loss are critical with
large numbers of disks
§ Mean time to data loss depends on mean time to failure,
and mean time to repair
• E.g., MTTF of 100,000 hours, mean time to repair of 10 hours gives
mean time to data loss of 500*106 hours (or 57,000 years) for a
mirrored pair of disks (ignoring dependent failure modes)
Load balance multiple small accesses to increase throughput
Parallelize large accesses to reduce response time.
§ Improve transfer rate by striping data across multiple disks.
§ Bit-level striping – split the bits of each byte across multiple disks
• In an array of eight disks, write bit i of each byte to disk i.
• Each access can read data at eight times the rate of a single disk.
• But seek/access time worse than for a single disk
§ Bit level striping is not used much any more
§ Block-level striping – with n disks, block i of a file goes to disk (i mod n)
1
• Requests for different blocks can run in parallel if the blocks reside on
different disks
• A request for a long sequence of blocks can utilize all disks in parallel
§ Schemes to provide redundancy at lower cost by using disk striping
combined with parity bits
• Different RAID organizations, or RAID levels, have differing cost,
performance and reliability characteristics
§ RAID Level 0: Block striping; non-redundant.
• Used in high-performance applications where data loss is not critical.
§ RAID Level 1: Mirrored disks with block striping
• Offers best write performance.
• Popular for applications such as storing log files in a database system.
§ Parity blocks: Parity block j stores XOR of bits from block j of each disk
• When writing data to a block j, parity block j must also be computed
and written to disk
§ Can be done by using old parity block, old value of current block
and new value of current block (2 block reads + 2 block writes)
§ Or by recomputing the parity value using the new values of blocks
corresponding to the parity block
• More efficient for writing large amounts of data sequentially
• To recover data for a block, compute XOR of bits from all other
blocks in the set including the parity block
§ RAID Level 5: Block-Interleaved Distributed Parity; partitions data and
parity among all N + 1 disks, rather than storing data in N disks and parity
in 1 disk.
• E.g., with 5 disks, parity block for nth set of blocks is stored on disk
(n mod 5) + 1, with the data blocks stored on the other 4 disks.
§ RAID Level 5 (Cont.)
• Block writes occur in parallel if the blocks and their parity blocks are
on different disks.
§ RAID Level 6: P+Q Redundancy scheme; similar to Level 5, but stores
two error correction blocks (P, Q) instead of single parity block to guard
against multiple disk failures.
• Better reliability than Level 5 at a higher cost
§ Becoming more important as storage sizes increase
§ Other levels (not used in practice):
• RAID Level 2: Memory-Style Error-Correcting-Codes (ECC) with bit
striping.
• RAID Level 3: Bit-Interleaved Parity
• RAID Level 4: Block-Interleaved Parity; uses block-level striping,
and keeps a parity block on a separate parity disk for corresponding
blocks from N other disks.
§ RAID 5 is better than RAID 4, since with RAID 4 with random
writes, parity disk gets much higher write load than other disks
and becomes a bottleneck
§ Factors in choosing RAID level
• Monetary cost
• Performance: Number of I/O
operations per second, and
bandwidth during normal operation
• Performance during failure
• Performance during rebuild of failed
disk
§ Including time taken to rebuild
failed disk
§ RAID 0 is used only when data safety is
not important
• E.g., data can be recovered quickly
from other sources
§ Level 1 provides much better write performance than level 5
• Level 5 requires at least 2 block reads and 2 block writes to write a
single block, whereas Level 1 only requires 2 block writes
§ Level 1 had higher storage cost than level 5
§ Level 5 is preferred for applications where writes are sequential and large
(many blocks), and need large amounts of data storage
§ RAID 1 is preferred for applications with many random/small updates
§ Level 6 gives better data protection than RAID 5 since it can tolerate two
disk (or disk block) failures
• Increasing in importance since latent block failures on one disk,
coupled with a failure of another disk can result in data loss with RAID
1 and RAID 5.
§ Software RAID: RAID implementations done entirely in software, with
no special hardware support
§ Hardware RAID: RAID implementations with special hardware
• Use non-volatile RAM to record writes that are being executed
• Beware: power failure during write can result in corrupted disk
§ E.g., failure after writing one block but before writing the second
in a mirrored system
§ Such corrupted data must be detected when power is restored
• Recovery from corruption is similar to recovery from failed
disk
• NV-RAM helps to efficiently detected potentially corrupted
blocks
§ Otherwise all blocks of disk must be read and compared
with mirror/parity block
§ Latent failures: data successfully written earlier gets damaged
• can result in data loss even if only one disk fails
§ Data scrubbing:
• continually scan for latent failures, and recover from copy/parity
§ Hot swapping: replacement of disk while system is running, without power
down
• Supported by some hardware RAID systems,
• reduces time to recovery, and improves availability greatly
§ Many systems maintain spare disks which are kept online, and used as
replacements for failed disks immediately on detection of failure
• Reduces time to recovery greatly
§ Many hardware RAID systems ensure that a single point of failure will not
stop the functioning of the system by using
• Redundant power supplies with battery backup
• Multiple controllers and multiple interconnections to guard against
controller/interconnection failures
§ Buffering: in-memory buffer to cache disk blocks
§ Read-ahead: Read extra blocks from a track in anticipation that they will
be requested soon
§ Disk-arm-scheduling algorithms re-order block requests so that disk arm
movement is minimized
• elevator algorithm
§ Buffering: in-memory buffer to cache disk blocks
§ Read-ahead: Read extra blocks from a track in anticipation that they will
be requested soon
§ Disk-arm-scheduling algorithms re-order block requests so that disk arm
movement is minimized
• elevator algorithm
§ Hold large volumes of data and provide high transfer rates
• Few GB for DAT (Digital Audio Tape) format, 10-40 GB with DLT
(Digital Linear Tape) format, 100 GB+ with Ultrium format, and 330 GB
with Ampex helical scan format
• Transfer rates from few to 10s of MB/s
§ Tapes are cheap, but cost of drives is very high
§ Very slow access time in comparison to magnetic and optical disks
• limited to sequential access.
• Some formats (Accelis) provide faster seek (10s of seconds) at cost of
lower capacity
§ Used mainly for backup, for storage of infrequently used information, and
as an off-line medium for transferring information from one system to
another.
§ Tape jukeboxes used for very large capacity storage
• Multiple petabyes (1015 bytes)
Chapter 12: Physical Storage Systems Simplified
Classification of Physical Storage Media
Volatile Storage: This is storage that loses all its data when the power is turned off. Examples include RAM (Random Access Memory).
Non-Volatile Storage: This type retains data even when there's no power. It includes devices like hard drives, flash drives, and tapes.
When choosing storage media, consider:
Speed: How quickly can data be accessed?
Cost: How much does it cost per unit of data stored?
Reliability: How dependable is the storage over time?
Storage Hierarchy
Primary Storage: This is the fastest storage and is volatile. It includes the CPU cache and main memory (RAM).
Secondary Storage: Slower than primary but non-volatile. It's generally used for data that doesn't need to be accessed as quickly. Examples are hard drives and SSDs (Solid State Drives).
Tertiary Storage: The slowest type, used mainly for backup and archival purposes. Examples include magnetic tapes and optical discs like DVDs.
Storage Interfaces
These are standards that define how storage devices connect to computers:
SATA (Serial ATA): A common interface for connecting hard drives and SSDs. SATA 3 supports transfer speeds up to 6 gigabits per second.
SAS (Serial Attached SCSI): Used in enterprise systems for higher performance, supporting speeds up to 12 gigabits per second.
NVMe (Non-Volatile Memory Express): Designed for faster storage devices like modern SSDs, supporting speeds up to 24 gigabits per second.
Storage can be connected in different ways:
Directly to the Computer: The traditional method where the storage device is inside or directly attached to the computer.
Storage Area Networks (SAN): A network that provides access to consolidated, block-level storage, making it appear like the storage is locally attached.
Network Attached Storage (NAS): A storage device connected to a network that allows storage and retrieval of data from a centralized location.
Magnetic Hard Disks
A magnetic hard disk is made up of:
Platters: Circular disks coated with magnetic material. Data is stored here.
Read/Write Heads: Devices that read data from and write data to the platters.
Tracks and Sectors: Platters are divided into tracks (concentric circles) and further into sectors (segments of the track). A sector is the smallest unit that can be read or written, typically 512 bytes.
To access data:
Seek Time: The read/write head moves to the correct track.
Rotational Latency: The platter spins so the correct sector is under the head.
Data Transfer: Data is read from or written to the sector.
Performance Measures of Disks
Access Time: Total time to start data transfer, including seek time and rotational latency.
Data Transfer Rate: Speed at which data can be read or written once the correct sector is under the head.
IOPS (Input/Output Operations Per Second): Number of read/write operations a disk can perform per second. For magnetic disks, this is typically between 50 and 200 IOPS.
Mean Time to Failure (MTTF): Average operational time before a disk is expected to fail. Typically measured in years.
RAID: Redundant Arrays of Independent Disks
RAID is a way to store the same data in different places (thus, redundantly) on multiple disks to protect data in the case of a drive failure.
Why Use RAID?
Improved Performance: By spreading data across multiple disks, read and write operations can be faster.
Increased Reliability: Redundancy means if one disk fails, data isn't lost.
RAID Levels
Different RAID configurations offer varying balances between performance and redundancy:
RAID 0 (Striping):
Description: Data is split across multiple disks.
Benefit: Improved performance.
Drawback: No redundancy; if one disk fails, all data is lost.
RAID 1 (Mirroring):
Description: Data is duplicated on two disks.
Benefit: High reliability; if one disk fails, the other has the data.
Drawback: Doubles storage cost since everything is stored twice.
RAID 5 (Striping with Parity):
Description: Data and parity (error-checking information) are spread across three or more disks.
Benefit: Balances performance and redundancy; can tolerate one disk failure.
Drawback: More complex; performance can be slower on write operations due to parity calculations.
RAID 6 (Striping with Double Parity):
Description: Similar to RAID 5 but with extra parity information.
Benefit: Can tolerate two disk failures.
Drawback: Even more complex and can have slower write performance.
Choosing a RAID Level
When selecting a RAID level, consider:
Cost: More redundancy typically means more disks are needed, increasing cost.
Performance Needs: RAID levels differ in read/write speeds.
Reliability Requirements: How critical is the data? Can you afford any data loss?
Rebuild Time: In case of failure, how quickly can the system recover?
Hardware Considerations
Software vs. Hardware RAID:
Software RAID: Managed by the computer's operating system.
Hardware RAID: Managed by a dedicated hardware controller; usually offers better performance and features like battery backup.
Data Scrubbing:
Regularly checking and correcting errors on disks to prevent data loss.
Hot Swapping:
The ability to replace a failed disk without shutting down the system, minimizing downtime.
Optimizing Disk Access
Buffering: Using memory to cache frequently accessed data to reduce disk reads.
Read-Ahead: Predicting and loading data into the cache before it is requested.
Disk Scheduling Algorithms:
Methods like the "elevator algorithm" optimize the order of disk access requests to reduce movement of the read/write head, improving performance.
Summary
Understanding physical storage systems is crucial for managing data effectively. By choosing the right storage media and configurations like RAID, you can optimize for speed, cost, and reliability based on your specific needs. Employing techniques like buffering and disk scheduling can further enhance performance.