To determine the required heat flux to maintain the internal surface of the rear window at 15 °C, we'll analyze the heat transfer through the glass and the surrounding fluids. Here's a step-by-step breakdown:
Given Data:
Step 1: Calculate Thermal Resistances (Per Unit Area)
-
Internal Convective Resistance (( R_i )):
[
R_i = \frac{1}{h_i} = \frac{1}{10} = 0.1 , \text{K·m²/W}
]
-
Conduction Through Glass (( R_{\text{cond}} )):
[
R_{\text{cond}} = \frac{L}{k} = \frac{0.004}{1.4} \approx 0.002857 , \text{K·m²/W}
]
-
External Convective Resistance (( R_o )):
[
R_o = \frac{1}{h_o} = \frac{1}{65} \approx 0.015385 , \text{K·m²/W}
]
Step 2: Establish Heat Balance
To maintain the internal surface at 15 °C, the heat provided by the internal fluid and the external heating must balance the heat conducted through the glass and the heat lost to the external fluid.
[
q_{\text{internal}} + q_{\text{heat}} = q_{\text{cond}} + q_{\text{external}}
]
Where:
- ( q_{\text{internal}} = h_i (T_{\text{internal fluid}} - T_i) = 10 \times (25 - 15) = 100 , \text{W/m²} )
- ( q_{\text{cond}} = \frac{T_i - T_o}{R_{\text{cond}}} = \frac{15 - T_o}{0.002857} = 350 (15 - T_o) , \text{W/m²} )
- ( q_{\text{external}} = h_o (T_o - T_{\text{external fluid}}) = 65 (T_o + 10) , \text{W/m²} )
Step 3: Solve for External Surface Temperature (( T_o ))
From the heat balance:
[
100 + q_{\text{heat}} = 350 (15 - T_o) + 65 (T_o + 10)
]
Assuming steady-state conditions without additional heating (( q_{\text{heat}} = 0 )), the equation balances the naturally conducted and convected heat:
[
350 (15 - T_o) = 65 (T_o + 10)
]
[
5250 - 350 T_o = 65 T_o + 650
]
[
5250 - 650 = 415 T_o
]
[
4600 = 415 T_o \implies T_o \approx 11.08 , \text{°C}
]
Step 4: Calculate Required Heating (( q_{\text{heat}} ))
Rearranging the heat balance equation to solve for ( q_{\text{heat}} ):
[
q_{\text{heat}} = 350 (15 - 11.08) - 100 \approx 350 \times 3.92 - 100 \approx 1372 - 100 = 1272 , \text{W/m²}
]
Conclusion:
To maintain the internal surface of the rear window at 15 °C, a heat flux of approximately 1270 W/m² must be supplied through the transparent electric resistance.
Final Answer:
A heat flux of approximately 1 270 W m⁻² must be supplied to maintain the window at 15 °C.