To determine the heat flux per unit area transmitted by the concrete wall and the temperatures of its internal and external surfaces, we'll analyze the problem using principles of steady-state heat transfer with convection on both sides of the wall.
Given Data:
- Wall Thickness, ( L ): 15 cm = 0.15 m
- Internal Ambient Temperature, ( T_{\text{internal, ambient}} ): 25°C
- External Ambient Temperature, ( T_{\text{external, ambient}} ): 0°C
- Internal Convection Coefficient, ( h_{\text{internal}} ): 10.5 W/m²·K
- External Convection Coefficient, ( h_{\text{external}} ): 52.3 W/m²·K
- Thermal Conductivity of Concrete, ( k ): 1.37 W/m·K
Objectives:
- Determine the heat flux per unit area (( q'' )) transmitted through the wall.
- Find the temperatures of the internal (( T_{\text{surface, internal}} )) and external (( T_{\text{surface, external}} )) surfaces of the wall.
1. Calculating Heat Flux per Unit Area (( q'' )):
In steady-state conditions, the heat transfer through the wall can be modeled using thermal resistances in series:
[
q'' = \frac{\Delta T}{R_{\text{total}}}
]
Where:
- ( \Delta T = T_{\text{internal, ambient}} - T_{\text{external, ambient}} = 25 , \text{°C} )
- Total Thermal Resistance, ( R_{\text{total}} ):
[
R_{\text{total}} = R_{\text{internal convection}} + R_{\text{conduction}} + R_{\text{external convection}}
]
[
R_{\text{total}} = \frac{1}{h_{\text{internal}}} + \frac{L}{k} + \frac{1}{h_{\text{external}}}
]
Plugging in the numbers:
[
R_{\text{total}} = \frac{1}{10.5} + \frac{0.15}{1.37} + \frac{1}{52.3} \approx 0.0952 + 0.1095 + 0.0191 = 0.2238 , \text{m²·K/W}
]
[
q'' = \frac{25}{0.2238} \approx 111.6 , \text{W/m²}
]
Rounded off:
[
q'' \approx 112 , \text{W/m²}
]
2. Determining Surface Temperatures:
Internal Surface Temperature (( T_{\text{surface, internal}} ))
[
q'' = h_{\text{internal}} (T_{\text{internal, ambient}} - T_{\text{surface, internal}})
]
[
112 = 10.5 (25 - T_{\text{surface, internal}})
]
[
25 - T_{\text{surface, internal}} = \frac{112}{10.5} \approx 10.67
]
[
T_{\text{surface, internal}} = 25 - 10.67 \approx 14.33 , \text{°C}
]
External Surface Temperature (( T_{\text{surface, external}} ))
[
q'' = h_{\text{external}} (T_{\text{surface, external}} - T_{\text{external, ambient}})
]
[
112 = 52.3 (T_{\text{surface, external}} - 0)
]
[
T_{\text{surface, external}} = \frac{112}{52.3} \approx 2.14 , \text{°C}
]
Summary of Results:
- Heat Flux per Unit Area, ( q'' ): 112 W/m²
- Internal Surface Temperature, ( T_{\text{surface, internal}} ): ≈14.3°C
- External Surface Temperature, ( T_{\text{surface, external}} ): ≈2.14°C
Verification:
To ensure consistency, let's verify the temperature drop across the wall due to conduction:
[
\Delta T = \frac{q'' \cdot L}{k} = \frac{112 \cdot 0.15}{1.37} \approx 12.26 , \text{°C}
]
[
T_{\text{surface, internal}} - T_{\text{surface, external}} \approx 14.33 - 2.14 = 12.19 , \text{°C}
]
The slight discrepancy is due to rounding during calculations, confirming the validity of our results.
Final Answer:
- The heat flux is approximately 112 W/m².
- The internal wall surface is about 14.3 °C and the external surface is approximately 2.14 °C.