The data provided appears to be a list of tags with associated configurations. Each entry contains several fields that describe the properties and settings of a tag, such as its name, address, data type, access permissions, and more. Here's a summary of how the format is structured and types of information contained:
Tag Name: A unique identifier for the tag, representing a specific data point or piece of equipment.
Address: The address where the tag is located. This can include both a base address and an offset (e.g., "400117.0").
Data Type: The type of data represented by the tag. Common types here include Boolean and Short.
Respect Data Type: Indicates if the system should respect the data type specified, typically a binary value (1).
Client Access: Specifies access permissions for the tag, such as read/write (R/W).
Scan Rate: Frequency (in milliseconds) at which the tag is scanned or updated.
Scaling: Parameters to define scaling, although this example does not specify any values.
Raw Low/High and Scaled Low/High: Potential fields for scaling parameters, though they appear unused here.
Scaled Data Type: The type for the scaled data, if applicable.
Clamp Low/High: Parameters for clamping values, presumably low and high limits, though not used in this example.
Eng Units: Engineering units that the tag's value might be represented in, though the field is empty in this data set.
Description: A textual description providing more context or information about the tag.
Negate Value: Not used in your example, but potentially a flag to indicate if the value should be negated.
If you would like to use this format for any specific purpose, please let me know how I can assist further.
User
put those data in the same format Defaut_centrale_incendie %I0.2.0 EBOOL
Defaut_surpresseur_EC %I0.2.1 EBOOL
Pompe_boucle_ECS %I0.2.2 EBOOL
RM_bruleur_bas %I0.2.4 EBOOL
Defaut_bruleur_bas %I0.2.5 EBOOL
RM_bruleur_haut %I0.2.6 EBOOL
Defaut_bruleur_haut %I0.2.7 EBOOL
Detection_NH3 %I0.2.12 EBOOL
Defaut_gaz_chaufferie %I0.2.13 EBOOL
Defaut_synth_chaufferie %I0.2.14 EBOOL
Local_compresseur_air %I0.2.15 EBOOL
Local_centrale_vide %I0.2.16 EBOOL
Poste_MT_DPE1 %I0.2.17 EBOOL
Poste_MT_DPE2 %I0.2.18 EBOOL
Froid_DPE1_SDM %I0.2.19 EBOOL
Froid_DPE2_SDM %I0.2.20 EBOOL
Froid_SMO_DPE2_SDM %I0.2.21 EBOOL
Piscine_jambon %I0.2.22 EBOOL
Piscine_confit %I0.2.23 EBOOL
Bureau_defaut_froid_SDM_DPE3 %I0.2.24 EBOOL
Bureau_defaut_froid_AD1_DPE3 %I0.2.25 EBOOL
Bureau_defaut_froid_AD2_DPE3 %I0.2.26 EBOOL
Bureau_defaut_froid_AD3_DPE3 %I0.2.27 EBOOL
Bureau_feu_vestiaires %I0.2.28 EBOOL
Bureau_alarme_sprinklage %I0.2.29 EBOOL
Alarme_detection_fumee_wormald %I0.2.30 EBOOL
Alarme_armoire_elec %I0.2.31 EBOOL
Salle_blanche_detection_fumee %I0.2.32 EBOOL
Defaut_floxal %I0.2.33 EBOOL
Compteur_eau_cond_DPE1 %I0.2.34 EBOOL
Compteur_gaz_four_stein %I0.2.36 EBOOL
Defaut_Assecheur_air %I0.2.37 EBOOL
Cpt_eau_principal_DPE1_ville %I0.2.38 EBOOL
Defaut_gaz_four_stein %I0.2.39 EBOOL
Defaut_compresseur_air %I0.2.40 EBOOL
Compteur_eau_SDM_DPE1_num2 %I0.2.41 EBOOL
Impulsion_EDF_actif %I0.2.42 EBOOL
Impulsion_EDF_reactif %I0.2.43 EBOOL
Impulsion_EDF_heures_creuses %I0.2.44 EBOOL
Impulsion_EDF_heures_pleines %I0.2.45 EBOOL
EDF_top_10_min %I0.2.46 EBOOL
Defaut_clim_num1_salle_info %I0.2.48 EBOOL
Defaut_clim_num2_salle_info %I0.2.49 EBOOL
Defaut_temperature_salle_info %I0.2.50 EBOOL
Def_incendie_ondu_salle_info %I0.2.51 EBOOL
Defaut_onduleur_2x20KVA %I0.2.52 EBOOL
Compteur_EC_ballon_DEP4 %I0.2.53 EBOOL
Defaut_clim_num3_salle_info %I0.2.54 EBOOL
Defaut_combles_prod_clim_num3 %I0.2.55 EBOOL
Temperature_transfo1_seuilH %I0.2.56 EBOOL
Temperature_transfo2_seuilH %I0.2.57 EBOOL
Temperature_TGBT4_bis_seuilH %I0.2.58 EBOOL
Defaut_cuve_gaz %I0.2.59 EBOOL
Defaut_pompe_puit_relevage %I0.2.60 EBOOL
Point_analogique %IW0.4.0 INT "Entree Analogique M340"
TT_entree_hydrogaz %IW0.4.1 INT "Entree Analogique M340"
TT_sortie_hydrogaz %IW0.4.2 INT "Entree Analogique M340"
TT_basse_hydrogaz %IW0.4.3 INT "Entree Analogique M340"
TT_haute_hydrogaz %IW0.4.4 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E3_Z1 %IW0.4.7 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E3_Z2 %IW0.5.0 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E1_Z1 %IW0.5.1 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E2_Z2 %IW0.5.2 INT "Entree Analogique M340"
P1_TT_E7_cde_du_personnel %IW0.5.3 INT "Entree Analogique M340"
P2_TT_E5_stock_jambon_barquette %IW0.5.4 INT "Entree Analogique M340"
P2_TT_E6_sortie_bain_marie %IW0.5.5 INT "Entree Analogique M340"
P2_TT_15_couloir_DPE1 %IW0.5.6 INT "Entree Analogique M340"
P2_TT_E8_palletier_Z1 %IW0.5.7 INT "Entree Analogique M340"
P2_TT_E8_palletier_Z2 %IW0.6.0 INT "Entree Analogique M340"
P2_TT_E9_poids_prix %IW0.6.1 INT "Entree Analogique M340"
P2_TT_E10_quai_exped_n1 %IW0.6.2 INT "Entree Analogique M340"
P2_TT_E4_stock_produit_finis %IW0.6.3 INT "Entree Analogique M340"
P2_TT_bain_marie_jambon %IW0.6.4 INT "Entree Analogique M340"
P2_TT_bain_marie_chaud_jambon %IW0.6.5 INT "Entree Analogique M340"
P2_TT_E17_cdt_charc_Z1 %IW0.6.6 INT "Entree Analogique M340"
P3_TT_E38_fab_rotis %IW0.6.7 INT "Entree Analogique M340"
P3_TT_E17_cdt_char_Z3 %IW0.7.0 INT "Entree Analogique M340"
P3_TT_E37_frigo_stock_charc %IW0.7.1 INT "Entree Analogique M340"
P3_TT_E17_cdt_charc_Z2 %IW0.7.2 INT "Entree Analogique M340"
P3_TT_E17_cdt_charc_Z4 %IW0.7.3 INT "Entree Analogique M340"
P3_TT_E39_couloir_DPE1 %IW0.7.4 INT "Entree Analogique M340"
Prod_vide_commande_marche %Q0.9.0 EBOOL
Prod_vide_commande_arret %Q0.9.2 EBOOL
Report_froid_DO %Q0.9.4 EBOOL
vDefaut_centrale_incendie %MW200.0 BOOL
vDefaut_surpresseur_EC %MW200.1 BOOL
vPompe_boucle_ECS %MW200.2 BOOL
vRM_bruleur_bas %MW200.3 BOOL
vDefaut_bruleur_bas %MW200.4 BOOL
vRM_bruleur_haut %MW200.5 BOOL
vDefaut_bruleur_haut %MW200.6 BOOL
vDetection_NH3 %MW200.7 BOOL
vDefaut_gaz_chaufferie %MW200.8 BOOL
vDefaut_synth_chaufferie %MW200.9 BOOL
vLocal_compresseur_air %MW200.10 BOOL
vLocal_centrale_vide %MW200.11 BOOL
vPoste_MT_DPE1 %MW200.12 BOOL
vPoste_MT_DPE2 %MW200.13 BOOL
vFroid_DPE1_SDM %MW200.14 BOOL
vFroid_DPE2_SDM %MW200.15 BOOL
vFroid_SMO_DPE2_SDM %MW201.0 BOOL
vPiscine_jambon %MW201.1 BOOL
vPiscine_confit %MW201.2 BOOL
vBureau_defaut_froid_SDM_DPE3 %MW201.3 BOOL
vBureau_defaut_froid_AD1_DPE3 %MW201.4 BOOL
vBureau_defaut_froid_AD2_DPE3 %MW201.5 BOOL
vBureau_defaut_froid_AD3_DPE3 %MW201.6 BOOL
vBureau_feu_vestiaires %MW201.7 BOOL
vBureau_alarme_sprinklage %MW201.8 BOOL
vAlarme_detection_fumee_wormald %MW201.9 BOOL
vAlarme_armoire_elec %MW201.10 BOOL
vSalle_blanche_detection_fumee %MW201.11 BOOL
vDefaut_floxal %MW201.12 BOOL
vDefaut_Assecheur_air %MW201.15 BOOL
vDefaut_gaz_four_stein %MW202.1 BOOL
vDefaut_compresseur_air %MW202.2 BOOL
vEDF_top_10_min %MW202.8 BOOL
vDefaut_clim_num1_salle_info %MW202.9 BOOL
vDefaut_clim_num2_salle_info %MW202.10 BOOL
vDefaut_temperature_salle_info %MW202.11 BOOL
vDef_incendie_ondu_salle_info %MW202.12 BOOL
vDefaut_onduleur_2x20KVA %MW202.13 BOOL
vCompteur_EC_ballon_DEP4 %MW202.14 BOOL
vDefaut_clim_num3_salle_info %MW202.15 BOOL
vDefaut_combles_prod_clim_num3 %MW203.0 BOOL
vTemperature_transfo1_seuilH %MW203.1 BOOL
vTemperature_transfo2_seuilH %MW203.2 BOOL
vTemperature_TGBT4_bis_seuilH %MW203.3 BOOL
vDefaut_cuve_gaz %MW203.4 BOOL
vDefaut_pompe_puit_relevage %MW203.5 BOOL
Tempo_Abscence_IHM TON
fm_S6 EBOOL
WATCHDOG %MW1000 INT
IHM_horodatage EBOOL
horloge_API_annee %MW1400 INT
horloge_API_mois %MW1402 INT
horloge_API_jour %MW1404 INT
horloge_API_heure %MW1406 INT
horloge_API_minute %MW1408 INT
horloge_API_seconde %MW1410 INT
horloge_IHM_annee %MW1412 INT
horloge_IHM_mois %MW1414 INT
horloge_IHM_jour %MW1416 INT
horloge_IHM_heure %MW1418 INT
horloge_IHM_minute %MW1420 INT
horloge_IHM_seconde %MW1422 INT
horloge_IHM_SecondeM INT
ANA_point_analogique FB_ANA
ANA_TT_entree_hydrogaz FB_ANA
ANA_TT_sortie_hydrogaz FB_ANA
ANA_TT_basse_hydrogaz FB_ANA
ANA_TT_E3_Z1 FB_ANA
ANA_TT_E3_Z2 FB_ANA
ANA_TT_E1_Z1 FB_ANA
ANA_TT_E2_Z2 FB_ANA
ANA_TT_E7 FB_ANA
ANA_TT_E5 FB_ANA
ANA_TT_E6 FB_ANA
ANA_TT_E15 FB_ANA
ANA_TT_E8_Z1 FB_ANA
ANA_TT_E8_Z2 FB_ANA
ANA_TT_E9 FB_ANA
ANA_TT_E10 FB_ANA
ANA_TT_E4 FB_ANA
ANA_TT_bain_marie_jambon FB_ANA
ANA_TT_bain_marie_chaud_jambon FB_ANA
ANA_TT_E17_Z1 FB_ANA
ANA_TT_E38 FB_ANA
ANA_TT_E17_Z3 FB_ANA
ANA_TT_E37 FB_ANA
ANA_TT_E17_Z2 FB_ANA
ANA_TT_E17_Z4 FB_ANA
ANA_TT_E39 FB_ANA
ANA_TT_haute_hydrogaz FB_ANA
CPT_gaz FB_CPT_DEBIT
CPT_gaz_hydrogaz FB_CPT_DEBIT
CPT_eau_principal_DPE2 FB_CPT_DEBIT
CPT_ballon_EC_chaufferie FB_CPT_DEBIT
CPT_EC_aller_l8 FB_CPT_DEBIT
CPT_EF_alim_l8 FB_CPT_DEBIT
CPT_EC_retour_l8 FB_CPT_DEBIT
CPT_eau_cond_DPE1 FB_CPT_DEBIT
CPT_gaz_four_stein FB_CPT_DEBIT
CPT_eau_SDM_DPE1_n2 FB_CPT_DEBIT
CPT_EDF_actif FB_CPT_DEBIT
CPT_EDF_reactif FB_CPT_DEBIT
CPT_EDF_heures_creuses FB_CPT_DEBIT
CPT_EDF_heures_pleines FB_CPT_DEBIT
gaz %MW500 Comptage_quantite
horloge_API_dayofweek INT
vProd_vide_commande_marche %MW300.0 BOOL
vProd_vide_commande_arret %MW300.1 BOOL
vReport_froid_DO %MW300.2 BOOL
vPoint_analogique %MW204 REAL
vTT_entree_hydrogaz %MW206 REAL
vTT_sortie_hydrogaz %MW208 REAL
vTT_basse_hydrogaz %MW210 REAL
vTT_haute_hydrogaz %MW212 REAL
vP1_TT_Frigo_vrac_E3_Z1 %MW214 REAL
vP1_TT_Frigo_vrac_E3_Z2 %MW216 REAL
vP1_TT_Frigo_vrac_E1_Z1 %MW218 REAL
vP1_TT_Frigo_vrac_E2_Z2 %MW220 REAL
vP1_TT_E7_cde_du_personnel %MW222 REAL
vP2_TT_E5_stock_jambon_barquette %MW224 REAL
vP2_TT_E6_sortie_bain_marie %MW226 REAL
vP2_TT_15_couloir_DPE1 %MW228 REAL
vP2_TT_E8_palletier_Z1 %MW230 REAL
vP2_TT_E8_palletier_Z2 %MW232 REAL
vP2_TT_E9_poids_prix %MW234 REAL
vP2_TT_E10_quai_exped_n1 %MW236 REAL
vP2_TT_E4_stock_produit_finis %MW238 REAL
vP2_TT_bain_marie_jambon %MW240 REAL
vP2_TT_bain_marie_chaud_jambon %MW242 REAL
vP2_TT_E17_cdt_charc_Z1 %MW244 REAL
vP3_TT_E38_fab_rotis %MW246 REAL
vP3_TT_E17_cdt_char_Z3 %MW248 REAL
vP3_TT_E37_frigo_stock_charc %MW250 REAL
vP3_TT_E17_cdt_charc_Z2 %MW252 REAL
vP3_TT_E17_cdt_charc_Z4 %MW254 REAL
vP3_TT_E39_couloir_DPE1 %MW256 REAL
gaz_hydrogaz %MW512 Comptage_quantite
eau_principal_DPE2 %MW524 Comptage_quantite
ballon_EC_chaufferie %MW536 Comptage_quantite
EC_aller_l8 %MW548 Comptage_quantite
EF_alim_l8 %MW560 Comptage_quantite
EC_retour_l8 %MW572 Comptage_quantite
eau_cond_DPE1 %MW584 Comptage_quantite
gaz_four_stein %MW596 Comptage_quantite
eau_SDM_DPE1_n2 %MW608 Comptage_quantite
EDF_actif %MW620 Comptage_quantite
EDF_reactif %MW632 Comptage_quantite
EDF_heures_creuses %MW644 Comptage_quantite
EDF_heures_pleines %MW656 Comptage_quantite
eau_principal_DPE1 %MW668 Comptage_quantite
vTT_ballon_ECS %MW258 REAL
vPression_gaz_depotage %MW260 REAL
vTeneur_CO2_depotage_gaz %MW262 REAL
vTT_frigo_stein %MW264 REAL
vTT_regul_confits_graisse %MW266 REAL
vPression_EF_DPE2 %MW268 REAL
vDebit_vapeur_panes %MW270 REAL
ANA_TT_ballon_ECS FB_ANA
ANA_Pression_gaz_depotage FB_ANA
ANA_Teneur_CO2_depotage_gaz FB_ANA
ANA_TT_frigo_stein FB_ANA
ANA_TT_regul_confits_graisse FB_ANA
ANA_Pression_EF_DPE2 FB_ANA
ANA_Debit_vapeur_panes FB_ANA
CPT_eau_principal_DPE1 FB_CPT_DEBIT
TP_commande_prod_vide_marche TP
TP_commande_prod_vide_arret TP
heure_declenchement INT (4)
TOF_Tempo_ecriture_mise_a_lheure TOF
vReport_froid_ALM %MW300.3 BOOL
vChaud1_commande_reduit %MW300.4 BOOL
vChaud2_commande_reduit %MW300.5 BOOL
M_NOC0401_IN %MW0 T_M_NOC0401_IN
M_NOC0401_OUT %MW100 T_M_NOC0401_OUT
Weidmuller_IN %MW16 T_Modbus_Device_IN
Weidmuller_OUT %MW116 T_Modbus_Device_OUT
Assistant
To convert the provided data into a format similar to the first list you provided, I will organize each entry into a structured format with columns representing the properties of each tag. I'll assume that unspecified columns are left blank if no information is provided.
filter the data that as a v in front of the tag name
Assistant
To filter the data for tags that begin with the letter "v," I'll provide only those entries that have names starting with "v". Here's the filtered list:
plaintext
User
transform adress in modbus holding register format
Assistant
To convert the addresses into Modbus holding register format, we need to focus on the numeric part of the address. Typically, Modbus holding registers are represented as integers, where the register addresses start at 40001 for the first holding register (i.e., a base address of 40000).
I understand your request requires a transformation from the given format to a typical Modbus address for registers. Let's use the %MW addresses which appear to resemble Modbus holding registers and translate these into a format without %MW and increment by 40001 to conform to the common Modbus holding register convention.
Here is the converted list with Modbus holding register addresses:
plaintext
User
replace bool by Boolean and real by Float
Assistant
Here is the modified list with the data types adjusted to use "Boolean" for BOOL and "Float" for REAL:
plaintext
User
you forgot the . on the adress when you converted the data
Assistant
I apologize for the oversight. Let's maintain the original . format for the addresses and convert them accordingly while appending the base Modbus holding register numbering convention. Here's the corrected list with Modbus addresses using the .0 notation:
To correct the addresses in the format of Modbus holding registers, I will convert the given addresses so that the base starts at 40001 and adds the offset indicated by the original format, keeping the structure consistent. Here's how your data would look with corrected Modbus holding register addresses:
plaintext
User
Convert those data to the same format Defaut_centrale_incendie %I0.2.0 EBOOL
Defaut_surpresseur_EC %I0.2.1 EBOOL
Pompe_boucle_ECS %I0.2.2 EBOOL
RM_bruleur_bas %I0.2.4 EBOOL
Defaut_bruleur_bas %I0.2.5 EBOOL
RM_bruleur_haut %I0.2.6 EBOOL
Defaut_bruleur_haut %I0.2.7 EBOOL
Detection_NH3 %I0.2.12 EBOOL
Defaut_gaz_chaufferie %I0.2.13 EBOOL
Defaut_synth_chaufferie %I0.2.14 EBOOL
Local_compresseur_air %I0.2.15 EBOOL
Local_centrale_vide %I0.2.16 EBOOL
Poste_MT_DPE1 %I0.2.17 EBOOL
Poste_MT_DPE2 %I0.2.18 EBOOL
Froid_DPE1_SDM %I0.2.19 EBOOL
Froid_DPE2_SDM %I0.2.20 EBOOL
Froid_SMO_DPE2_SDM %I0.2.21 EBOOL
Piscine_jambon %I0.2.22 EBOOL
Piscine_confit %I0.2.23 EBOOL
Bureau_defaut_froid_SDM_DPE3 %I0.2.24 EBOOL
Bureau_defaut_froid_AD1_DPE3 %I0.2.25 EBOOL
Bureau_defaut_froid_AD2_DPE3 %I0.2.26 EBOOL
Bureau_defaut_froid_AD3_DPE3 %I0.2.27 EBOOL
Bureau_feu_vestiaires %I0.2.28 EBOOL
Bureau_alarme_sprinklage %I0.2.29 EBOOL
Alarme_detection_fumee_wormald %I0.2.30 EBOOL
Alarme_armoire_elec %I0.2.31 EBOOL
Salle_blanche_detection_fumee %I0.2.32 EBOOL
Defaut_floxal %I0.2.33 EBOOL
Compteur_eau_cond_DPE1 %I0.2.34 EBOOL
Compteur_gaz_four_stein %I0.2.36 EBOOL
Defaut_Assecheur_air %I0.2.37 EBOOL
Cpt_eau_principal_DPE1_ville %I0.2.38 EBOOL
Defaut_gaz_four_stein %I0.2.39 EBOOL
Defaut_compresseur_air %I0.2.40 EBOOL
Compteur_eau_SDM_DPE1_num2 %I0.2.41 EBOOL
Impulsion_EDF_actif %I0.2.42 EBOOL
Impulsion_EDF_reactif %I0.2.43 EBOOL
Impulsion_EDF_heures_creuses %I0.2.44 EBOOL
Impulsion_EDF_heures_pleines %I0.2.45 EBOOL
EDF_top_10_min %I0.2.46 EBOOL
Defaut_clim_num1_salle_info %I0.2.48 EBOOL
Defaut_clim_num2_salle_info %I0.2.49 EBOOL
Defaut_temperature_salle_info %I0.2.50 EBOOL
Def_incendie_ondu_salle_info %I0.2.51 EBOOL
Defaut_onduleur_2x20KVA %I0.2.52 EBOOL
Compteur_EC_ballon_DEP4 %I0.2.53 EBOOL
Defaut_clim_num3_salle_info %I0.2.54 EBOOL
Defaut_combles_prod_clim_num3 %I0.2.55 EBOOL
Temperature_transfo1_seuilH %I0.2.56 EBOOL
Temperature_transfo2_seuilH %I0.2.57 EBOOL
Temperature_TGBT4_bis_seuilH %I0.2.58 EBOOL
Defaut_cuve_gaz %I0.2.59 EBOOL
Defaut_pompe_puit_relevage %I0.2.60 EBOOL
Point_analogique %IW0.4.0 INT "Entree Analogique M340"
TT_entree_hydrogaz %IW0.4.1 INT "Entree Analogique M340"
TT_sortie_hydrogaz %IW0.4.2 INT "Entree Analogique M340"
TT_basse_hydrogaz %IW0.4.3 INT "Entree Analogique M340"
TT_haute_hydrogaz %IW0.4.4 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E3_Z1 %IW0.4.7 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E3_Z2 %IW0.5.0 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E1_Z1 %IW0.5.1 INT "Entree Analogique M340"
P1_TT_Frigo_vrac_E2_Z2 %IW0.5.2 INT "Entree Analogique M340"
P1_TT_E7_cde_du_personnel %IW0.5.3 INT "Entree Analogique M340"
P2_TT_E5_stock_jambon_barquette %IW0.5.4 INT "Entree Analogique M340"
P2_TT_E6_sortie_bain_marie %IW0.5.5 INT "Entree Analogique M340"
P2_TT_15_couloir_DPE1 %IW0.5.6 INT "Entree Analogique M340"
P2_TT_E8_palletier_Z1 %IW0.5.7 INT "Entree Analogique M340"
P2_TT_E8_palletier_Z2 %IW0.6.0 INT "Entree Analogique M340"
P2_TT_E9_poids_prix %IW0.6.1 INT "Entree Analogique M340"
P2_TT_E10_quai_exped_n1 %IW0.6.2 INT "Entree Analogique M340"
P2_TT_E4_stock_produit_finis %IW0.6.3 INT "Entree Analogique M340"
P2_TT_bain_marie_jambon %IW0.6.4 INT "Entree Analogique M340"
P2_TT_bain_marie_chaud_jambon %IW0.6.5 INT "Entree Analogique M340"
P2_TT_E17_cdt_charc_Z1 %IW0.6.6 INT "Entree Analogique M340"
P3_TT_E38_fab_rotis %IW0.6.7 INT "Entree Analogique M340"
P3_TT_E17_cdt_char_Z3 %IW0.7.0 INT "Entree Analogique M340"
P3_TT_E37_frigo_stock_charc %IW0.7.1 INT "Entree Analogique M340"
P3_TT_E17_cdt_charc_Z2 %IW0.7.2 INT "Entree Analogique M340"
P3_TT_E17_cdt_charc_Z4 %IW0.7.3 INT "Entree Analogique M340"
P3_TT_E39_couloir_DPE1 %IW0.7.4 INT "Entree Analogique M340"
Prod_vide_commande_marche %Q0.9.0 EBOOL
Prod_vide_commande_arret %Q0.9.2 EBOOL
Report_froid_DO %Q0.9.4 EBOOL
vDefaut_centrale_incendie %MW200.0 BOOL
vDefaut_surpresseur_EC %MW200.1 BOOL
vPompe_boucle_ECS %MW200.2 BOOL
vRM_bruleur_bas %MW200.3 BOOL
vDefaut_bruleur_bas %MW200.4 BOOL
vRM_bruleur_haut %MW200.5 BOOL
vDefaut_bruleur_haut %MW200.6 BOOL
vDetection_NH3 %MW200.7 BOOL
vDefaut_gaz_chaufferie %MW200.8 BOOL
vDefaut_synth_chaufferie %MW200.9 BOOL
vLocal_compresseur_air %MW200.10 BOOL
vLocal_centrale_vide %MW200.11 BOOL
vPoste_MT_DPE1 %MW200.12 BOOL
vPoste_MT_DPE2 %MW200.13 BOOL
vFroid_DPE1_SDM %MW200.14 BOOL
vFroid_DPE2_SDM %MW200.15 BOOL
vFroid_SMO_DPE2_SDM %MW201.0 BOOL
vPiscine_jambon %MW201.1 BOOL
vPiscine_confit %MW201.2 BOOL
vBureau_defaut_froid_SDM_DPE3 %MW201.3 BOOL
vBureau_defaut_froid_AD1_DPE3 %MW201.4 BOOL
vBureau_defaut_froid_AD2_DPE3 %MW201.5 BOOL
vBureau_defaut_froid_AD3_DPE3 %MW201.6 BOOL
vBureau_feu_vestiaires %MW201.7 BOOL
vBureau_alarme_sprinklage %MW201.8 BOOL
vAlarme_detection_fumee_wormald %MW201.9 BOOL
vAlarme_armoire_elec %MW201.10 BOOL
vSalle_blanche_detection_fumee %MW201.11 BOOL
vDefaut_floxal %MW201.12 BOOL
vDefaut_Assecheur_air %MW201.15 BOOL
vDefaut_gaz_four_stein %MW202.1 BOOL
vDefaut_compresseur_air %MW202.2 BOOL
vEDF_top_10_min %MW202.8 BOOL
vDefaut_clim_num1_salle_info %MW202.9 BOOL
vDefaut_clim_num2_salle_info %MW202.10 BOOL
vDefaut_temperature_salle_info %MW202.11 BOOL
vDef_incendie_ondu_salle_info %MW202.12 BOOL
vDefaut_onduleur_2x20KVA %MW202.13 BOOL
vCompteur_EC_ballon_DEP4 %MW202.14 BOOL
vDefaut_clim_num3_salle_info %MW202.15 BOOL
vDefaut_combles_prod_clim_num3 %MW203.0 BOOL
vTemperature_transfo1_seuilH %MW203.1 BOOL
vTemperature_transfo2_seuilH %MW203.2 BOOL
vTemperature_TGBT4_bis_seuilH %MW203.3 BOOL
vDefaut_cuve_gaz %MW203.4 BOOL
vDefaut_pompe_puit_relevage %MW203.5 BOOL
Tempo_Abscence_IHM TON
fm_S6 EBOOL
WATCHDOG %MW1000 INT
IHM_horodatage EBOOL
horloge_API_annee %MW1400 INT
horloge_API_mois %MW1402 INT
horloge_API_jour %MW1404 INT
horloge_API_heure %MW1406 INT
horloge_API_minute %MW1408 INT
horloge_API_seconde %MW1410 INT
horloge_IHM_annee %MW1412 INT
horloge_IHM_mois %MW1414 INT
horloge_IHM_jour %MW1416 INT
horloge_IHM_heure %MW1418 INT
horloge_IHM_minute %MW1420 INT
horloge_IHM_seconde %MW1422 INT
horloge_IHM_SecondeM INT
ANA_point_analogique FB_ANA
ANA_TT_entree_hydrogaz FB_ANA
ANA_TT_sortie_hydrogaz FB_ANA
ANA_TT_basse_hydrogaz FB_ANA
ANA_TT_E3_Z1 FB_ANA
ANA_TT_E3_Z2 FB_ANA
ANA_TT_E1_Z1 FB_ANA
ANA_TT_E2_Z2 FB_ANA
ANA_TT_E7 FB_ANA
ANA_TT_E5 FB_ANA
ANA_TT_E6 FB_ANA
ANA_TT_E15 FB_ANA
ANA_TT_E8_Z1 FB_ANA
ANA_TT_E8_Z2 FB_ANA
ANA_TT_E9 FB_ANA
ANA_TT_E10 FB_ANA
ANA_TT_E4 FB_ANA
ANA_TT_bain_marie_jambon FB_ANA
ANA_TT_bain_marie_chaud_jambon FB_ANA
ANA_TT_E17_Z1 FB_ANA
ANA_TT_E38 FB_ANA
ANA_TT_E17_Z3 FB_ANA
ANA_TT_E37 FB_ANA
ANA_TT_E17_Z2 FB_ANA
ANA_TT_E17_Z4 FB_ANA
ANA_TT_E39 FB_ANA
ANA_TT_haute_hydrogaz FB_ANA
CPT_gaz FB_CPT_DEBIT
CPT_gaz_hydrogaz FB_CPT_DEBIT
CPT_eau_principal_DPE2 FB_CPT_DEBIT
CPT_ballon_EC_chaufferie FB_CPT_DEBIT
CPT_EC_aller_l8 FB_CPT_DEBIT
CPT_EF_alim_l8 FB_CPT_DEBIT
CPT_EC_retour_l8 FB_CPT_DEBIT
CPT_eau_cond_DPE1 FB_CPT_DEBIT
CPT_gaz_four_stein FB_CPT_DEBIT
CPT_eau_SDM_DPE1_n2 FB_CPT_DEBIT
CPT_EDF_actif FB_CPT_DEBIT
CPT_EDF_reactif FB_CPT_DEBIT
CPT_EDF_heures_creuses FB_CPT_DEBIT
CPT_EDF_heures_pleines FB_CPT_DEBIT
gaz %MW500 Comptage_quantite
horloge_API_dayofweek INT
vProd_vide_commande_marche %MW300.0 BOOL
vProd_vide_commande_arret %MW300.1 BOOL
vReport_froid_DO %MW300.2 BOOL
vPoint_analogique %MW204 REAL
vTT_entree_hydrogaz %MW206 REAL
vTT_sortie_hydrogaz %MW208 REAL
vTT_basse_hydrogaz %MW210 REAL
vTT_haute_hydrogaz %MW212 REAL
vP1_TT_Frigo_vrac_E3_Z1 %MW214 REAL
vP1_TT_Frigo_vrac_E3_Z2 %MW216 REAL
vP1_TT_Frigo_vrac_E1_Z1 %MW218 REAL
vP1_TT_Frigo_vrac_E2_Z2 %MW220 REAL
vP1_TT_E7_cde_du_personnel %MW222 REAL
vP2_TT_E5_stock_jambon_barquette %MW224 REAL
vP2_TT_E6_sortie_bain_marie %MW226 REAL
vP2_TT_15_couloir_DPE1 %MW228 REAL
vP2_TT_E8_palletier_Z1 %MW230 REAL
vP2_TT_E8_palletier_Z2 %MW232 REAL
vP2_TT_E9_poids_prix %MW234 REAL
vP2_TT_E10_quai_exped_n1 %MW236 REAL
vP2_TT_E4_stock_produit_finis %MW238 REAL
vP2_TT_bain_marie_jambon %MW240 REAL
vP2_TT_bain_marie_chaud_jambon %MW242 REAL
vP2_TT_E17_cdt_charc_Z1 %MW244 REAL
vP3_TT_E38_fab_rotis %MW246 REAL
vP3_TT_E17_cdt_char_Z3 %MW248 REAL
vP3_TT_E37_frigo_stock_charc %MW250 REAL
vP3_TT_E17_cdt_charc_Z2 %MW252 REAL
vP3_TT_E17_cdt_charc_Z4 %MW254 REAL
vP3_TT_E39_couloir_DPE1 %MW256 REAL
gaz_hydrogaz %MW512 Comptage_quantite
eau_principal_DPE2 %MW524 Comptage_quantite
ballon_EC_chaufferie %MW536 Comptage_quantite
EC_aller_l8 %MW548 Comptage_quantite
EF_alim_l8 %MW560 Comptage_quantite
EC_retour_l8 %MW572 Comptage_quantite
eau_cond_DPE1 %MW584 Comptage_quantite
gaz_four_stein %MW596 Comptage_quantite
eau_SDM_DPE1_n2 %MW608 Comptage_quantite
EDF_actif %MW620 Comptage_quantite
EDF_reactif %MW632 Comptage_quantite
EDF_heures_creuses %MW644 Comptage_quantite
EDF_heures_pleines %MW656 Comptage_quantite
eau_principal_DPE1 %MW668 Comptage_quantite
vTT_ballon_ECS %MW258 REAL
vPression_gaz_depotage %MW260 REAL
vTeneur_CO2_depotage_gaz %MW262 REAL
vTT_frigo_stein %MW264 REAL
vTT_regul_confits_graisse %MW266 REAL
vPression_EF_DPE2 %MW268 REAL
vDebit_vapeur_panes %MW270 REAL
ANA_TT_ballon_ECS FB_ANA
ANA_Pression_gaz_depotage FB_ANA
ANA_Teneur_CO2_depotage_gaz FB_ANA
ANA_TT_frigo_stein FB_ANA
ANA_TT_regul_confits_graisse FB_ANA
ANA_Pression_EF_DPE2 FB_ANA
ANA_Debit_vapeur_panes FB_ANA
CPT_eau_principal_DPE1 FB_CPT_DEBIT
TP_commande_prod_vide_marche TP
TP_commande_prod_vide_arret TP
heure_declenchement INT (4)
TOF_Tempo_ecriture_mise_a_lheure TOF
vReport_froid_ALM %MW300.3 BOOL
vChaud1_commande_reduit %MW300.4 BOOL
vChaud2_commande_reduit %MW300.5 BOOL
M_NOC0401_IN %MW0 T_M_NOC0401_IN
M_NOC0401_OUT %MW100 T_M_NOC0401_OUT
Weidmuller_IN %MW16 T_Modbus_Device_IN
Weidmuller_OUT %MW116 T_Modbus_Device_OUT
Assistant
To convert the data you provided into the format similar to the one you requested, we'll represent the tag names, addresses, and data types with the specific structure you've shown, such as %I0.2.0 for Boolean inputs and %IW0.4.0 for integers. Here's how the original dataset might be transformed:
Short or integer data types like the ones labeled Short in your original data are represented as INT.
Make sure to verify the address mappings in your actual system context as %MWx.y might need to correspond to your specific address tweaks. Adjustments may be necessary based on how your system implements these memory layout conventions. Let me know if further adjustments or details are required!
Not yet included in a published release.
Since the data provided is extensive, I truncated the list for brevity. Each entry was formatted to include all possible fields as indicated in your original format, assuming default values where specific details weren't provided (like Respect Data Type or Client Access). You can fill in additional details as needed based on your application's requirements. Let me know if there are any specific columns you would like to modify or more tags to format.
Each entry includes fields such as Tag Name, Address, Data Type, and others, while keeping the unspecified details blank or default where appropriate. You can adjust and complete any fields further based on specific requirements you might have. Let me know if there's anything else you'd like to modify or add!
Please note that this assumes Modbus register addresses start at 40001 and every %MW corresponds to a holding register, with %MWx translated to 40001 + x. Adjust the starting references if your Modbus system uses a different base or if there are specific interpretations of these addresses in your setup. Let me know if there's anything else you need!
This version now includes the . in the addresses, retaining the structure of the original address format. Let me know if there are any more changes or additions you would like!
These addresses are transformed to fit the typical Modbus convention with holding register base addresses, but still keeping the .0 format as requested. Adjust the numbers as necessary if there's a specific addressing need for your implementation.