It looks like you're attempting to implement the Hilbert transform in the frequency domain using assembly with SIMD instructions. The Hilbert transform is a specific linear operator that shifts the phase of each frequency component by (-90^\circ) (or (\pi/2) radians). Typically, in the frequency domain, this is achieved by multiplying the positive frequency components by (-i) and the negative frequency components by (i), while leaving the DC (0 Hz) and Nyquist (if applicable) components unchanged.
However, based on your code, it seems you're implementing a more general phase shift rather than the standard Hilbert transform. Here are several potential issues and recommendations to ensure your Hilbert transform implementation is correct:
1. Incorrect Implementation of the Hilbert Transform
Standard Hilbert Transform in Frequency Domain:
- DC and Nyquist Frequencies: Leave unchanged.
- Positive Frequencies: Multiply by (2).
- Negative Frequencies: Set to (0).
This approach ensures that the resulting signal is analytic, with only positive frequency components.
Your Implementation:
- You're applying a frequency-dependent phase shift based on a calculated angle, which seems more complex than necessary for the Hilbert transform.
- The Hilbert transform doesn't require phase shifts based on frequency magnitude; it has a fixed phase shift of (-90^\circ) for positive frequencies and (+90^\circ) for negative frequencies.
Recommendation:
Simplify your implementation to adhere to the standard Hilbert transform approach. This can be done by:
- Positive Frequencies (excluding Nyquist): Multiply both the real and imaginary parts by (2).
- Negative Frequencies: Set both the real and imaginary parts to (0).
- DC and Nyquist: Leave unchanged.
2. Complex Multiplication Errors
Your code attempts to perform complex multiplication manually, but the approach seems error-prone:
-
Positive Frequencies:
- You calculate
cos(a) and sin(a) based on some frequency-dependent angle (a), which isn't necessary for the Hilbert transform.
- The complex multiplication should be straightforward ((a + ib) multiplied by (-i) results in (b - ia)).
-
Negative Frequencies:
- Similarly, multiplying by (i) should be direct without involving (cos(a)) and (sin(a)).
Recommendation:
Remove the unnecessary phase shift calculations and directly apply the multipliers:
- For positive frequencies, set the real part to (-\text{Im}) and the imaginary part to (\text{Re}).
- For negative frequencies, set both parts to (0).
In assembly, this can be optimized using SIMD operations without computing trigonometric functions.
3. Frequency Index Handling and Ordering
- Frequency Ordering: Ensure that your
brx array correctly maps the unordered frequency bins to the natural order expected by your processing.
- Loop Increment (
add eax, 16): Verify that you're correctly iterating over each frequency bin. If each bin consists of two complex numbers (for stereo channels, perhaps), ensure that your stride (16 bytes) correctly maps to the data structure.
Recommendation:
Double-check the frequency ordering and loop increments to ensure all relevant bins are processed correctly without skipping or overlapping.
4. Phase Angle Calculation and Normalization
Your phase angle calculation involves several steps:
- Converting frequency bin indices to floating-point.
- Normalizing and calculating (-\tan(a)).
- Using polynomial approximations (
ta1, ta3, ta5, etc.) to compute the phase shift.
This complexity introduces multiple points where errors can occur, especially with low-frequency bins where division by small numbers can lead to inaccuracies.
Recommendation:
Since the Hilbert transform doesn't require variable phase shifts, eliminate these calculations. Stick to fixed multipliers ((-i) for positive frequencies and (i) for negative frequencies, or simply setting negative frequencies to zero if creating an analytic signal).
5. Optimizing with SIMD Instructions
To leverage SIMD effectively for the Hilbert transform:
-
Positive Frequencies:
- Swap the real and imaginary parts.
- Negate the new imaginary parts (effectively multiplying by (-i)).
-
Negative Frequencies:
-
DC and Nyquist:
Sample SIMD Optimization:
; Assuming xmm0 contains (Re_L, Im_L, Re_R, Im_R)
; For positive frequencies:
; (Re, Im) * (-i) = (Im, -Re)
shufps xmm0, xmm0, 0xB1 ; Shuffle to (Im_L, Re_L, Im_R, Re_R)
xorps xmm0, mask_neg_re ; Negate Re parts, assuming mask_neg_re has -0.0 for Re components
; Store back
movaps outData[ebx], xmm0
Note:
mask_neg_re should be a constant with 0x80000000 in the bit positions corresponding to the real parts to negate them.
- Ensure that you handle both stereo channels correctly if applicable.
6. Verification and Testing
After implementing the simplified Hilbert transform:
- Test with Known Signals: Use simple signals (like sine or cosine waves) to verify the phase shift.
- Compare with Reference Implementations: Ensure your results match those from established libraries (e.g., MATLAB’s
hilbert function).
7. Final Simplified Implementation Suggestion
Here’s a high-level outline for a standard Hilbert transform in the frequency domain using assembly-like pseudocode:
push ebx
mov eax, 0
fDomainLoop:
mov ebx, brx[eax] ; Get ordered frequency index
movaps xmm0, inData[ebx] ; Load complex data (Re, Im)
cmp ebx, 0
je skipModify ; Skip DC
cmp ebx, half_n
je skipModify ; Skip Nyquist if applicable
cmp ebx, half_n
jl positiveFreq
jge negativeFreq
positiveFreq:
; Multiply by -i: (Re, Im) -> (Im, -Re)
shufps xmm0, xmm0, 0xB1 ; Shuffle to (Im, Re)
xorps xmm0, mask_neg_re ; Negate Re
jmp storeData
negativeFreq:
; Zero out negative frequencies
xorps xmm0, xmm0 ; Set to (0, 0)
jmp storeData
storeData:
movaps outData[ebx], xmm0
add eax, 16
cmp eax, N[0]
jl fDomainLoop
skipModify:
movaps outData[ebx], xmm0
add eax, 16
cmp eax, N[0]
jl fDomainLoop
pop ebx
; End Fourier domain processing
Constants:
mask_neg_re should have 0x80000000 in the real parts to negate them when XORed.
Conclusion
Your current implementation introduces unnecessary complexity by calculating frequency-dependent phase shifts, which diverges from the standard Hilbert transform approach. By simplifying the process to directly apply fixed multipliers for positive and negative frequencies, you can ensure the correctness of the transform and improve performance. Additionally, carefully manage frequency bin indexing and leverage SIMD instructions effectively to optimize the implementation.
If you still intend to perform a more generalized phase shift beyond the Hilbert transform, ensure that the phase shift calculations are mathematically sound and that complex multiplications are correctly implemented. However, for the Hilbert transform specifically, adhering to the standard frequency domain multipliers is recommended.