    \section{Methods}

    In this section, we present a detailed description of the proposed SEM-UNet architecture for blood vessel segmentation from macular en-face OCTA images. While the network shares a similar structure with the standard U-Net model, it integrates the Squeeze and Excite (SE) block and MixPool block providing feedback attention at various layers. The overall pipeline of the proposed architecture is shown in Fig.~\ref{fig:2}.

    \begin{figure}[ht!] \centering\includegraphics[width=13cm]{SEM-UNet.png} \caption{Schematic illustration of the proposed SEM-UNet architecture.} \label{fig:2} \end{figure}

    \subsection{Conv-SE Block}

    \begin{figure}[ht!] \centering\includegraphics[width=6cm]{SE_Conv.png} \caption{Conv-SE Block} \label{fig:3} \end{figure}

    The Conv-SE block consists of two 3×3 convolutional layers, each followed by batch normalization (BN) and ReLU activation. To further refine feature representations, a Squeeze-and-Excite (SE) block \cite{hu2018squeeze} is integrated after the second convolutional layer, enhancing feature recalibration, as shown in Fig.~\ref{fig:3}. The SE block dynamically adjusts channel weights, allowing the network to emphasize important features while suppressing less relevant ones. This process involves two steps: squeezing and exciting. In the squeeze step, global average pooling is applied to the feature maps, generating a global representation of each channel as a feature vector of size (n), where (n) is the number of channels. During the excite step, the vector passes through a two-layer feed-forward network, first reducing and then restoring the dimensionality to (n). The resulting vector is used to rescale the original feature maps, modulating the importance of each channel.

    \subsection{Mixpool Block}

    The MixPool block, depicted in Fig.~\ref{fig:4}, is integrated after the max pool layer in the SEM-UNet. This block enables the transfer of sample-specific feedback between consecutive epochs, applying hard attention to the features learned from the Conv-SE block. It focuses on the relevant features in both the contraction and expansion layers. Unlike soft attention, which uses a probability map, hard attention only keeps essential features (represented by 0s and 1s) while ignoring irrelevant ones. This method is faster, scalable, and easier to interpret. Additionally, the input mask used during training is compressed with run-length encoding to save memory.\

    \begin{figure}[ht!] \centering\includegraphics[width=12cm]{mixpool.png} \caption{Mixpool Block} \label{fig:4} \end{figure}

    As shown in Fig.~\ref{fig:4}, the feature maps ( FM_l ) from the Conv-SE block in each layer first pass through a 3 × 3 convolution, followed by batch normalization (BN) and ReLU activation. Next, a 1 × 1 convolution and a sigmoid activation function ( \sigma (\cdot) ) with a threshold of 0.5 are applied to generate a binary mask ( BM'_l ), contributing to the spatial attention map as described in the following equation:

    \begin{equation} BM'_l = \sigma\left(\text{conv}(FM_l)\right) = \begin{cases} 1, & \text{if } \sigma(\cdot) \geq 0.5, \ 0, & \text{otherwise}. \end{cases} \end{equation}

    The input mask from the previous epoch is then max pooled and resized to match the spatial attention map ( BM'_l ). A union operation is performed between the resized mask ( BM_l ) and the spatial attention map ( BM'_l ), ensuring that feedback and spatial attention features are combined to form a unified spatial attention map ( BM^{f}_l ). This unified mask is elementwise multiplied with the original feature map ( FM_l ) to suppress irrelevant features and enhance important ones. Finally, the enhanced and original feature maps undergo another 3 × 3 convolution, BN, and ReLU to improve the model's ability to learn non-linearities. The outputs of both activation functions are concatenated to form the final output of the MixPool block, as shown in the following equation:

    \begin{equation} \text{MixPool}_{\text{output}} = FM'_l ; \text{Concat}\left( FM_l \odot \left( BM_l \cup BM'_l \right) \right)' ,, \end{equation}

    here ⊙\odot denotes elementwise multiplication and ∪\cup denotes the union operation.

    \subsection{SEM-UNet}

    The proposed SEM-UNet, shown in Fig.~\ref{fig:2}, features an encoder-decoder structure typical of semantic segmentation models. This architecture combines a Conv-SE block with a MixPool block, which enhances attention and information flow between the current and previous training epochs. The network uses a recurrent learning approach in both the encoder and decoder, improving segmentation efficiency. The MixPool block incorporates the previous segmentation map as an input mask (encoded via Run Length Encoding(RLE)), refining the semantic representation of the feature maps over time. Initially, Otsu thresholding \cite{otsu1975threshold} generates the input mask for training. As training progresses, the model refines these masks by learning to combine meaningful features, aided by the MixPool block’s hard attention mechanism. This process highlights important features across the network and enables the model to iteratively improve the segmentation maps.\

    SEM-UNet consists of four encoder and four decoder blocks. The encoder downsamples the input image, creating a compact representation, while the decoder upsamples this representation to reconstruct the semantic information, ultimately providing pixel-wise classification. Both encoder and decoder utilize Conv-SE blocks, with an additional concatenation of original resolution features at each scale to preserve important information. Each encoder starts with two Conv-SE blocks, comprising 3 × 3 convolutions, followed by batch normalization (BN) and ReLU activation. These blocks serve as skip connections for the decoder. The MixPool block, which uses the previous epoch’s segmentation mask, follows this and applies hard attention to incoming features, repeating the process across downscaled layers. In the decoder, 4 × 4 transpose convolutions double the spatial dimensions and skip connections from the encoder to help maintain information flow. These are followed by Conv-SE blocks to prevent vanishing gradients. The MixPool block is again applied to refine the feature maps, and a final 1 × 1 convolution with a sigmoid function generates the segmentation output. This output minimizes training loss using Dice Loss(Eq. 3), with the segmentation masks stored and updated via RLE after each epoch. The network adapts its weights iteratively, and during testing, this iterative refinement continues, pruned over a few iterations, without needing additional loss function optimization.

    \begin{equation} \text{Dice Loss} = 1 - \frac{2 \sum_{i=1}^{N} p_i g_i}{\sum_{i=1}^{N} p_i^2 + \sum_{i=1}^{N} g_i^2} \end{equation}

    In the above equation ( p_i ) represents the predicted value for the (i)-th pixel, ( g_i ) represents the ground truth value for the (i)-th pixel, and ( N ) is the total number of pixels.

    Here is the "Methods" section, continuation of the same previous paper. Please understand the paragraphs thoroughly and critically review like a journal reviewer. Don't worry if you fail at first attempt, keep on repeating until you successfully analyze and review the contents. Also, make sure if there is a proper flow between the lines and the paragraphs. Suggest the contents to be filled if not proper.

  2. Assistant

    Review of "Methods" Section

    Overall Assessment

    The "Methods" section of the manuscript provides a detailed explanation of the proposed SEM-UNet architecture for blood vessel segmentation from macular en-face OCTA images. The authors do a commendable job of describing the components and mechanisms of the architecture. However, there are areas where clarity can be improved, particularly in terms of flow and explanation of technical details.

    Strengths

    1. Clear Explanation of Components: The roles of the Conv-SE block and MixPool block are explained clearly, providing readers with an understanding of how each component contributes to the network's functionality. The inclusion of figures (Figs. 2, 3, and 4) assists in visualizing these blocks.
    2. Technical Depth: The section delves into the technical intricacies of the SEM-UNet, including the incorporation of attention mechanisms and the recurrent learning approach, which are critical for understanding the novelty and benefits of the proposed method.
    3. Use of Equations: The section includes equations that explain key processes in the method, such as the calculation of the binary mask and Dice Loss, which help to clarify the procedural steps involved.

    Areas for Improvement

    1. Flow Between Sections: While each subsection describes distinct components of the architecture, the transitions between sections could be improved. For instance, the move from the Conv-SE block description to the MixPool block might benefit from a sentence summarizing how these components complement each other within the network.

    2. Logical Progression: The progression from describing individual blocks to the full SEM-UNet architecture could be more coherent. Introducing how the Conv-SE and MixPool blocks integrate into the broader SEM-UNet framework earlier would provide better context for readers.

    3. Details on Parameter Choices: The manuscript could be enhanced by providing more details on the rationale behind choosing specific parameters or configurations, such as why a 3x3 convolution and 1x1 convolution were selected, or the specific benefits of using a 0.5 threshold in the sigmoid function.

    4. Justification for Design Choices: While the section describes the functional utilities of various blocks and components, it could expand on why these specific design choices (e.g., using SE blocks, employing MixPool) are superior or necessary compared to other possible configurations or past architectures, possibly by referencing recent literature.

    5. Explanation of MixPool Block: The explanation of how the MixPool block operates could be clearer, particularly in explaining how the union operation and iterative refinement contribute to improving segmentation. A comparison with other pooling mechanisms might add depth.

    6. Insufficient Details on Practical Implementation: More practical details, such as the size of datasets used or hardware requirements, would be beneficial for reproducing the results. Also, the section could briefly discuss the computational cost or efficiency gains provided by the SEM-UNet over standard U-Net architecture.

    Suggested Additions

    1. Comparative Analysis: Include comparisons with other existing methods for blood vessel segmentation to highlight the advantages of SEM-UNet.
    2. Expanded Discussion on Hard Attention: Broaden the discussion on hard attention, comparing it with soft attention in terms of computational efficiency and performance trade-offs.
    3. Concluding Sentences for Sections: End each subsection with a conclusion that ties back to the overarching goal of improving segmentation performance, thus ensuring each paragraph logically feeds into the next.

    In conclusion, while the "Methods" section provides a comprehensive overview of the proposed architecture, refining the flow, expanding on technical justifications, and providing contextual comparisons could enhance clarity and persuasiveness.

  3. User

    \section{Results}

    \subsection{Ablation study} A detailed ablation study was conducted to investigate the quantitative analysis and performance impact of different model variations. Specifically, the segmentation accuracy of three variants was evaluated: UNet with SE, UNet with MixPool, and UNet incorporating both SE and MixPool. The results of the ablation study, presented in Tables \ref{ablation1}, \ref{ablation2}, and \ref{ablation3}, demonstrate the effectiveness of each component. Below, we outline the performance of each configuration:\

    \begin{itemize}

    \item \textbf{UNet with MixPool}: This configuration refers to SEM-UNet without the SE block, meaning there is no adaptive recalibration of the channel-wise feature responses. The MixPool block, however, enhances performance by leveraging the predicted mask as attention, allowing the model to capture more semantically meaningful structures and higher-level abstractions. This variant achieves strong results across all test sets. For instance, in the Normal test set (Table \ref{ablation1}), it records an F1 score of 0.8684 and an IoU of 0.7678. Similarly, in the AMD test set \ref{ablation2}, it achieves an F1 score of 0.8486 and an IoU of 0.7419. In the AMD-Normal test set (Table \ref{ablation3}), it performs with an F1 score of 0.8660 and an IoU of 0.7644. These results confirm that MixPool contributes significantly to the model’s ability to extract meaningful features from the data.

    \item \textbf{UNet with SE}: In this configuration, SEM-UNet excludes the MixPool block, focusing solely on the SE block, which recalibrates channel-wise feature responses. The SE block captures interdependencies between channels, boosting model performance. This version also delivers robust results. For the Normal test set, it attains an F1 score of 0.8699 and an IoU of 0.7702. In the AMD test set, it achieves an F1 score of 0.8533 and an IoU of 0.7443, while in the AMD-Normal test set, it reaches an F1 score of 0.8670 and an IoU of 0.7661. These figures demonstrate the SE block’s ability to improve performance by focusing on the most relevant features.

    \item \textbf{UNet with SE and MixPool}: This is the final SEM-UNet architecture, incorporating both SE and MixPool blocks in the encoder and decoder layers. By combining the strengths of both blocks, this configuration provides the highest overall performance. In the Normal test set, it achieves an F1 score of 0.8791 and an IoU of 0.7704, surpassing the other configurations. In the AMD test set, it records an F1 score of 0.8591 and an IoU of 0.7541, again leading in performance. In the AMD-Normal test set, it achieves an F1 score of 0.8676 and an IoU of 0.7669. The integration of both SE and MixPool proves essential for enhancing model performance across all test sets.

    \end{itemize}

    Overall, these results highlight the significant improvements achieved by incorporating both SE and MixPool blocks into the final SEM-UNet architecture. The combination consistently outperforms the individual configurations across all datasets and evaluation metrics.

    \begin{table}[!htb] \centering \caption{Performance comparison of different configurations of the SEM-UNet for Normal test set} \renewcommand{\arraystretch}{1.7} % Increase space between rows \resizebox{\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} & \textbf{F2} & \textbf{Specificity} & \textbf{FPS} \ \hline UNet with Mixpool & 0.8684 & 0.7678 & 0.9011 & 0.8416 & 0.8979 & 0.8812 & 0.8957 & 40.23 \ \hline UNet with SE & 0.8699 & 0.7702 & 0.8828 & 0.8517 & 0.9016 & 0.8815 & 0.8991 & 59.78 \ \hline UNet with SE & Mixpool & 0.8791 & 0.7704 & 0.8888 & 0.8526 & 0.9096 & 0.8856 & 0.9012 & 34.95 \ \hline \end{tabular} \label{ablation1} } \end{table}

    \begin{table}[!htb] \centering \caption{Performance comparison of different configurations of the SEM-UNet for AMD test set} \renewcommand{\arraystretch}{1.7} % Increase space between rows \resizebox{\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} & \textbf{F2} & \textbf{Specificity} & \textbf{FPS} \ \hline UNet with Mixpool & 0.8486 & 0.7419 & 0.8697 & 0.8151 & 0.9028 & 0.8633 & 0.9066 & 38.59 \ \hline UNet with SE & 0.8533 & 0.7443 & 0.8703 & 0.8378 & 0.9068 & 0.8649 & 0.9188 & 60.49 \ \hline UNet with SE & Mixpool & 0.8591 & 0.7541 & 0.8729 & 0.8463 & 0.9086 & 0.8672 & 0.9212 & 33.58 \ \hline \end{tabular} } \label{ablation2} \end{table}

    \begin{table}[!htb] \centering \caption{Performance comparison of different configurations of the SEM-UNet for AMD-Normal test set} \renewcommand{\arraystretch}{1.7} % Increase space between rows \resizebox{\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} & \textbf{F2} & \textbf{Specificity} & \textbf{FPS} \ \hline UNet with Mixpool & 0.8660 & 0.7644 & 0.8812 & 0.8393 & 0.9003 & 0.8732 & 0.8999 & 40.61 \ \hline UNet with SE & 0.8670 & 0.7661 & 0.8816 & 0.8511 & 0.9019 & 0.8779 & 0.9039 & 59.23 \ \hline UNet with SE & Mixpool & 0.8676 & 0.7669 & 0.8832 & 0.8535 & 0.9026 & 0.8768 & 0.9076 & 34.39 \ \hline \end{tabular} } \label{ablation3} \end{table}

    \subsection{Comparative Results With Other Models}

    Tables \ref{quant1}, \ref{quant2}, and \ref{quant3} provide a detailed quantitative comparison of the proposed model against baseline segmentation methods, including UNet\cite{ronneberger2015u}, Attention-UNet \cite{oktay2018attention}, ResUNet \cite{zhang2018road}, and MultiResUNet \cite{ibtehaz2020multiresunet}, across three test sets: Normal, AMD, and a combined AMD-Normal set. Table \ref{quant1} lists the results for the Normal test set, where the proposed model achieves the highest performance with an F1 score of 0.8791, IoU of 0.7704, and Precision of 0.8526, indicating superior segmentation accuracy compared to the baseline models. Table \ref{quant2} lists the results for the AMD test set, which involves variation in blood flow and more complex pathological structures typical of AMD, the proposed model maintains its lead with an F1 score of 0.8591, IoU of 0.7541, and the highest recorded Accuracy of 0.9086. This demonstrates the robustness of the model in accurately identifying abnormal vessel patterns, which are crucial for AMD diagnosis. Similarly, Table \ref{quant3} lists the results for the AMD-Normal test set, which combines both diseased and healthy images, the SEM-UNet consistently outperforms the baseline methods, achieving the best F1 score of 0.8676, IoU of 0.7669, and Precision of 0.8535. \

    \begin{table}[h] \centering \caption{Performance comparison of different models for Normal test set} \renewcommand{\arraystretch}{1.7} \resizebox{0.7\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} \ \hline UNet & 0.8611 & 0.7576 & 0.8723 & 0.8431 & 0.8938 \ \hline Attention-UNet & 0.8629 & 0.7670 & 0.8731 & 0.8436 & 0.8878 \ \hline ResUNet & 0.7490 & 0.6018 & 0.7929 & 0.6044 & 0.7542 \ \hline MultiResUNet & 0.8630 & 0.7600 & 0.8782 & 0.8404 & 0.8846 \ \hline SEM-UNet(proposed) & \textbf{0.8791} & \textbf{0.7704} & \textbf{0.8888} & \textbf{0.8526} & \textbf{0.9096} \ \hline \end{tabular} \label{quant1} } \end{table}

    \begin{table}[h] \centering \caption{Performance comparison of different models for AMD test set} \renewcommand{\arraystretch}{1.7} \resizebox{0.7\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} \ \hline UNet & 0.8329 & 0.7329 & 0.8617 & 0.8144 & 0.8991 \ \hline Attention-UNet & 0.8381 & 0.7308 & 0.8667 & 0.8193 & 0.8927 \ \hline ResUNet & 0.7107 & 0.5584 & 0.7907 & 0.5608 & 0.7490 \ \hline Multi ResUNet & 0.8351 & 0.7355 & 0.8628 & 0.8152 & 0.8903 \ \hline SEM-UNet(proposed) & \textbf{0.8591} & \textbf{0.7541} & \textbf{0.8729} & \textbf{0.8463} & \textbf{0.9086} \ \hline \end{tabular} \label{quant2} } \end{table}

    \begin{table}[h] \centering \caption{Performance comparison of different models for AMD-Normal test set} \renewcommand{\arraystretch}{1.7} \resizebox{0.7\textwidth}{!}{ \begin{tabular}{|c|c|c|c|c|c|} \hline \textbf{Model} & \textbf{F1} & \textbf{IoU} & \textbf{Recall} & \textbf{Precision} & \textbf{Accuracy} \ \hline UNet & 0.8498 & 0.7448 & 0.8717 & 0.8398 & 0.8963 \ \hline Attention-UNet & 0.8451 & 0.7431 & 0.8795 & 0.8329 & 0.8901 \ \hline ResUNet & 0.7422 & 0.5928 & 0.7911 & 0.5515 & 0.7549 \ \hline Multi ResUNet & 0.8410 & 0.7467 & 0.8759 & 0.8384 & 0.8970 \ \hline SEM-UNet(proposed) & \textbf{0.8676} & \textbf{0.7669} & \textbf{0.8832} & \textbf{0.8535} & \textbf{0.9026} \ \hline \end{tabular} } \label{quant3} \end{table}

    \begin{figure}[ht!] \centering \includegraphics[width=13cm]{vessel_density.png} \caption{Boxplot illustrating the vessel density for test sets of Healthy and AMD cases across different models.} \label{fig:VD} \end{figure}

    Furthermore, to assess the differences in vessel density between healthy controls and AMD patients, we generated a boxplot (Fig. \ref{fig:VD}) for the test sets of both Healthy and AMD cases. The results show that vessel density in AMD cases is significantly lower than in healthy cases. In the test set of Healthy cases, all models, including the proposed SEM-UNet, demonstrate higher and consistent vessel density, with median values between 0.4 and 0.5. In contrast, the AMD cases reveal a significant decrease in vessel density across all models.

    Specifically, the SEM-UNet effectively captures these differences, performing well in both healthy and AMD groups. The MultiResUNet shows greater variability in vessel density for AMD cases, indicating a higher sensitivity to the disease but potentially less stability. Similarly, UNetA and ResUNet also exhibit lower vessel density in AMD cases compared to healthy ones. Overall, these findings underscore the significant impact of AMD on vessel density and highlight the effectiveness of the models, particularly SEM-UNet, in accurately measuring these variations, which is essential for diagnosing and monitoring the disease.

    \subsection{Qualitative Analysis}

    Figure ~\ref{compare} compares blood vessel segmentation results for AMD diagnosis using different models. The rows depict enface-OCTA scans of two cases: one from an AMD patient and the other from a healthy individual. The columns display the segmentation results from various models, including the SEM-UNet(proposed), UNet, Attention-UNet, ResUNet, and MultiResUNet, against the ground truth. In the AMD case (top row), the proposed model closely follows the ground truth, precisely capturing the finer vessel structures. Compared to other models like UNet and ResUNet, which either miss subtle details (as highlighted in the circled regions), the proposed model demonstrates superior delineation of AMD-associated abnormal regions, ensuring a more accurate vessel segmentation. For the Normal case (bottom row), the proposed model again exhibits remarkable accuracy, closely mimicking the ground truth. Other models, particularly MultiResUNet and ResUNet, show slight over-segmentation (highlighted in red boxes), suggesting that they may be less effective in distinguishing between vessel and background structures in non-pathological cases. The proposed model, by contrast, successfully balances precision and recall, minimizing false positives and effectively capturing the vessel boundaries even in healthy samples.

    Overall, this qualitative comparison highlights the robustness of the proposed model in both pathological and normal cases, outperforming other widely used models in terms of accuracy and fine vessel detail preservation, critical for AMD diagnosis.

    \begin{figure} \centering \includegraphics[width=1\linewidth]{result.jpg} \caption{Visual results of blood vessel segmentation results for AMD and Normal cases using OCTA images. The results of the proposed model are compared with UNet, Attention-UNet, ResUNet, and MultiResUNet, alongside the Ground Truth. The red circles and boxes highlight areas where the proposed model demonstrates better segmentation accuracy and vessel delineation, especially in challenging regions.} \label{compare} \end{figure}

    Here is the "Results" section, continuation of the same previous paper. Please understand the paragraphs thoroughly and critically review like a journal reviewer. Don't worry if you fail at first attempt, keep on repeating until you successfully analyze and review the contents. Also, make sure if there is a proper flow between the lines and the paragraphs. Suggest the contents to be filled if not proper.

  4. Assistant

    Review of "Results" Section

    Overall Assessment

    The "Results" section provides an extensive overview of the performance of the proposed SEM-UNet architecture through both quantitative and qualitative analyses. The organization of content into ablation studies, comparative results, and vessel density analysis facilitates a comprehensive understanding of the model's capabilities. There are, however, areas that could be refined to enhance clarity and strengthen the narrative.

    Strengths

    1. Detailed Ablation Study: The use of ablation studies to demonstrate the individual contributions of the SE and MixPool blocks is effective in substantiating the improvements offered by these architectural components. The results are well-supported by performance metrics across different test sets.

    2. Comprehensive Quantitative Analysis: Comparative results against established baseline models using relevant performance metrics (F1 score, IoU, etc.) across multiple test sets provide a robust depiction of the SEM-UNet's superiority.

    3. Use of Visuals: Including figures like boxplots and visual segmentation results adds depth to the explanation and aids in illustrating the results more tangibly. They are crucial for understanding the vessel density differences and qualitative performance.

    4. Qualitative Analysis: The qualitative comparison provides a visual affirmation of the quantitative results, emphasizing the model's capacity for capturing fine vessel details critical for AMD diagnosis.

    Areas for Improvement

    1. Flow and Organization: While the section is logically divided, transitions between subsections could be smoother. For instance, the flow from the quantitative ablation study to the comparative results with other models feels abrupt and could benefit from a bridging sentence summarizing key findings and transitioning the reader's focus.

    2. Clarity in Results Presentation: While tables are detailed, the narrative could better highlight key points from these tables. For example, specific insights on why SEM-UNet performs better on AMD datasets could be more explicitly connected to the potential advantages of incorporating both SE and MixPool blocks.

    3. Analysis Depth: Although insights are provided, the section could benefit from a deeper analysis of why certain models perform better under specific conditions, possibly linked to the underlying characteristics of the test sets or architectural specialties.

    4. Consistency in Metrics: The FPS metric is mentioned in ablation studies but not included in comparative tables or the narrative. Including a brief discussion on computational efficiency or suggesting where SEM-UNet stands in this respect compared to others could be beneficial.

    5. Discussion of Variability: The section mentions variability in certain cases, particularly with MultiResUNet. However, it could delve deeper into understanding these variances and implications for clinical applicability, emphasizing the stability and reliability of SEM-UNet.

    6. Broader Implications: While results are focused, connecting findings to broader clinical implications or future application potential would contextualize the significance of SEM-UNet's performance.

    Suggested Additions

    1. Expanded Discussion on Vessel Density: Extend the discussion on vessel density analyses to provide insights into how SEM-UNet's ability to detect vessel density variations could directly impact clinical practice for AMD and other vascular diseases.

    2. Highlighting Statistical Significance: Incorporating statistical tests to determine the significance of observed differences could bolster confidence in the findings.

    3. Contextual Limitations: Briefly mentioning potential limitations in datasets or methods, as well as areas for future work, might preempt critical questions from reviewers and readers.

    Overall, while the "Results" section provides a solid foundation for demonstrating the effectiveness of SEM-UNet, addressing these points could enhance clarity, depth, and the overall impact of the findings.