2. ANALYSIS CONDITIONS This section shall contain detailed definition about sources,…
- User
-
ANALYSIS CONDITIONS This section shall contain detailed definition about sources, waveforms and frequency ranges for each E3 which constitute the cardinal requirement set. This section shall also contain clearance criteria for each E3. Bu bölümü aşağıda vereceğim bilgiler doğrultusunda yaz. 6.4.1.1 Conducted and Radiated Emission Tests Conducted and radiated emission tests to be applied according to MIL-STD 461G standard are shown in Table 4. Table 4 CE and RE Tests MIL-STD-461G Description Category Test Equipments CE102 Conducted Emissions, Power Leads, 10 kHz to 10 Mhz. This test procedure is used to verify that electromagnetic emissions from the EUT do not exceed the specified requirements for power input leads, including returns. Figure CE102-1
- Measurement receiver
- Data recording device
- Signal generator
- Attenuator, 20 dB, 50 ohm
- Oscilloscope
- LISNs RE102 Radiated Emissions, Electric Field, 2MHz to 18 Ghz. This test procedure is used to verify that electric field emissions from the EUT and its associated cabling do not exceed specified requirements. Figure RE102-3. Fixed Wing Internal, <25 meters Nose to Tail - Measurement receivers.
- Data recording device.
- Antennas
- Signal generators.
- Stub radiator.
- Capacitor, 10 pF.
- LISNs. 6.4.1.2 Conducted and Radiated Susceptibility Tests Conducted and Radiated Susceptibility tests to be applied according to MIL-STD 461G standard are shown in Table 5. Table 5 Susceptibility Tests MIL-STD-461G Description Category Test Equipments CS101 Conducted Susceptibility, Power Leads, 30 Hz to 150 kHz. This test procedure is used to verify the ability of the EUT to withstand signals coupled onto input power leads. Figure CS101-1 Voltage Limit Figure CS101-2 Power Limit - Signal generator
- Power amplifier
- Oscilloscope or measurement receiver
- Coupling transformer
- Capacitor, 10 uF
- Isolation transformer
- Resistor, 0.5 ohm
- LISNs
CS114 Conducted Susceptibility, Bulk Cable Injection, 10kHz to 200 MHz. This test procedure is used to verify the ability of the EUT to withstand RF signals coupled onto EUT associated cabling. Table VI Figure CS114-1, Curve #5 - Measurement receivers
-
Current injection probes -Current probes
-
Calibration fixture: coaxial transmission line with 50 ohm characteristic impedance, coaxial connections on both ends, and space for an injection probe around the center conductor.
-
Directional couplers
-
Signal generators
-