make wire digram for The banding machine is used at a paper mill to place metal straps…

  1. User

    make wire digram for The banding machine is used at a paper mill to place metal straps around paper rolls in preparation for shipping. The plant PLC will control the conveyor and communicate with the banding machine to place the band at the correct position on the paper roll. This lab will focus on simulating the PLC control for the conveyor and the process of finding the center of the paper roll for banding.

    Requirements: When the start button is pressed, the conveyor should start (assuming there are no alarms). When Photo Eye 1 (PE1) detects the paper roll, a timer should begin timing the length of the paper roll. Once the roll clears PE1, the accumulated time should be moved to a register using the MOV instruction, allowing the PLC to calculate the center of the roll. Photo Eye 2 (PE2) will trigger a second timer to stop the conveyor at the center of the roll, allowing the banding machine to place the band.

    Input and Output Assignments: Discrete Inputs: Conveyor Stop Button – Input 0 Conveyor Start Button – Input 1 Photo Eye 1 (PE1) – Input 2 Photo Eye 2 (PE2) – Input 3 Conveyor Running Feedback Signal – Input 4 Alarm Reset Switch – Input 5 Relay Outputs: Conveyor Start/Stop (Lightbulb 0) – Output 0

  2. Assistant

    Creating a wire diagram for the described PLC-controlled conveyor and banding machine system involves mapping out the connections between all physical components, including the PLC, input devices (like push buttons and photo eyes), output devices (like the conveyor motor starter), power supplies, and any necessary relays or contactors.

    Below is a comprehensive guide to help you create the wire diagram for your system.


    Components Overview

    1. PLC (Programmable Logic Controller)

    • Input Module: Discrete inputs for sensors and switches.
    • Output Module: Relay outputs to control actuators.

    2. Input Devices

    • Conveyor Stop Button – Input 0
    • Conveyor Start Button – Input 1
    • Photo Eye 1 (PE1) – Input 2
    • Photo Eye 2 (PE2) – Input 3
    • Conveyor Running Feedback Signal – Input 4
    • Alarm Reset Switch – Input 5

    3. Output Devices

    • Conveyor Start/Stop Control – Output 0 (connected to a relay or directly to the conveyor starter if appropriate)

    4. Power Supplies

    • Control Power Supply: Typically 24V DC for the PLC and input devices.
    • Motor Power Supply: May be AC, appropriate for the conveyor motor.

    Wiring the Inputs

    Power Supply Connections

    • 24V DC Positive (+): Connect to one side of all input devices (common positive bus).
    • 24V DC Negative (−): Connect to the COM (common) terminals of the PLC input module.

    Input Wiring

    1. Conveyor Stop Button (Input 0)

      • Use a Normally Closed (NC) push button for safety.
      • One terminal connected to +24V DC.
      • Other terminal connected to PLC Input 0.
    2. Conveyor Start Button (Input 1)

      • Use a Normally Open (NO) push button.
      • One terminal connected to +24V DC.
      • Other terminal connected to PLC Input 1.
    3. Photo Eye 1 (PE1) (Input 2)

      • Sensor output connected to PLC Input 2.
      • Sensor power connected to +24V DC and 24V DC (−).
    4. Photo Eye 2 (PE2) (Input 3)

      • Sensor output connected to PLC Input 3.
      • Sensor power connected to +24V DC and 24V DC (−).
    5. Conveyor Running Feedback Signal (Input 4)

      • If available, use an auxiliary contact from the conveyor starter.
      • Contact connected between +24V DC and PLC Input 4.
    6. Alarm Reset Switch (Input 5)

      • Use an NO push button.
      • One terminal connected to +24V DC.
      • Other terminal connected to PLC Input 5.

    Wiring the Outputs

    Conveyor Start/Stop Control (Output 0)

    1. PLC Output Module

      • Typically provides a set of relay contacts (dry contacts).
      • Ensure the relay contacts are rated for the control voltage and current of the conveyor starter coil.
    2. Wiring Steps

      • Common (COM) Terminal: Connect to the neutral or negative side of the control power supply (depends on whether the output module is sinking or sourcing).
      • Output 0 Terminal: Connect to one side of the conveyor starter coil (or an interposing relay if necessary).
      • Other side of the conveyor starter coil: Connect to the control power supply (e.g., +24V DC or control voltage appropriate for the starter coil).
    3. Lightbulb Simulation

      • If simulating, replace the conveyor starter coil with a lightbulb (Lightbulb 0) that operates at the control voltage.

    Detailed Wiring Diagram Explanation

    1. Input Side Wiring

    a. Power Distribution

    • +24V DC Rail

      ----------------------------+24V DC-----------------------------
                                     |
                             +--------------+
                             |              |
                       [Stop Button]   [Start Button]
                             |              |
                       [PLC Input 0]   [PLC Input 1]
      
    • 24V DC (−) Rail

      • Connects to the COM terminal of the PLC input module.
      • Connects to the negative terminals of photo eyes and any other devices requiring a return path.

    b. Photo Eyes Wiring

    • Photo Eye Power

      +24V DC ---- [PE1 Power +]     [PE2 Power +]
      24V DC (−) ---- [PE1 Power −]     [PE2 Power −]
      
    • Photo Eye Outputs

      [PE1 Output] ---- [PLC Input 2]
      [PE2 Output] ---- [PLC Input 3]
      

    c. Conveyor Running Feedback Signal

    • Auxiliary Contact from Conveyor Starter

      +24V DC ---- [Auxiliary Contact NO]
                       |
                  [PLC Input 4]
      

    d. Alarm Reset Switch

    +24V DC ---- [Alarm Reset Switch NO] ---- [PLC Input 5]
    

    2. Output Side Wiring

    a. PLC Output Module

    • Relay Output

      [PLC Output 0 NO Contact]
         COM ----+             +---- To Conveyor Starter Coil (A1)
                 |             |
               [Relay Contacts Closing on Output Activation]
                 |             |
      24V DC (−) ----+             +---- Conveyor Starter Coil (A2)
      
    • Conveyor Starter Coil Control Circuit

      • If control voltage is AC, use an interposing relay energized by the PLC output, which in turn controls the AC starter coil.
      • If control voltage is DC and compatible with PLC output, connect as per above.

    Simplified ASCII Diagram

    [Power Supply +24V DC]--------------------+------------------+------------------+
                                              |                  |                  |
                                       [Start Button]      [Stop Button NC]   [Alarm Reset Switch]
                                              |                  |                  |
                                      [Input 1 (PLC)]     [Input 0 (PLC)]     [Input 5 (PLC)]
    
    [Power Supply +24V DC]--------------------+------------------+
                                              |                  |
                                     [PE1 Power +]       [PE2 Power +]
                                     [PE1 Output]        [PE2 Output]
                                              |                  |
                                      [Input 2 (PLC)]     [Input 3 (PLC)]
    
    [Conveyor Starter Aux NO]----------------[Input 4 (PLC)]
    
    [PLC Output 0]----[Conveyor Starter Coil or Relay]
    

    Additional Notes

    • Safety Considerations

      • Emergency Stop (E-Stop): Implement an E-Stop circuit that cuts power to the conveyor motor directly, bypassing the PLC for immediate response.
      • Stop Button: Should be NC so that if a wire breaks, the conveyor stops.
      • Fusing/Overcurrent Protection: Include appropriate fuses or circuit breakers.
    • Sensor Details

      • Photo Eyes (PE1 and PE2): Ensure they're wired correctly according to manufacturer specifications (NPN vs. PNP output).
      • Shielded Cables: Use for sensor wiring to prevent electrical noise.
    • Grounding

      • Proper grounding of the PLC, power supplies, and shielding is crucial for safety and noise immunity.
    • Labels and Documentation

      • Label all wires, terminals, and devices for easy maintenance.
      • Keep updated schematics and diagrams accessible.

    Implementing the PLC Program

    While the wire diagram focuses on the physical connections, ensure that your PLC program includes:

    • Start/Stop Logic

      • Latching circuit to keep the conveyor running after the Start button is pressed.
      • Conveyor stops when the Stop button is pressed or in case of an alarm.
    • Timing Logic

      • Timer 1: Starts when PE1 detects the roll (leading edge) and stops when the roll clears PE1 (trailing edge).
      • MOV Instruction: Moves the elapsed time from Timer 1 to a register for center calculation.
      • Timer 2: Activated by PE2 to delay stopping the conveyor at the roll's center.

    Final Steps

    • Review All Connections

      • Double-check each wire against the diagram for accuracy.
    • Testing

      • Power up the system and test each input and output individually.
      • Use simulation tools if available to test the PLC program logic.
    • Safety Checks

      • Test E-Stop and safety interlocks.
      • Ensure that the conveyor stops when any safety device is activated.

    By following this guide, you should be able to create a detailed and accurate wire diagram for your PLC-controlled conveyor system. Remember to adhere to all relevant electrical codes and standards, and consult with a professional electrician or engineer if necessary.