Certainly! Let's compute the Function Point Count (FPC) step-by-step based on the provided functional units and system requirements.
Step 1: Determine Unadjusted Function Points (UFP)
Function Point Analysis categorizes software functions into five primary types:
- External Inputs (EI)
- External Outputs (EO)
- External Inquiries (EQ)
- Internal Logical Files (ILF)
- External Interface Files (EIF)
Each function type is assigned a weight based on its complexity: Low, Average, or High. We'll use the IFPUG (International Function Point Users Group) weighting standards for this calculation.
1. Assign Weights to Each Function Type
| Function Type | Low Complexity | Average Complexity | High Complexity |
|---|
| External Inputs (EI) | 3 FP | 4 FP | 6 FP |
| External Outputs (EO) | 4 FP | 5 FP | 7 FP |
| External Inquiries (EQ) | 3 FP | 4 FP | 6 FP |
| Internal Logical Files (ILF) | 7 FP | 10 FP | 15 FP |
| External Interface Files (EIF) | 5 FP | 7 FP | 10 FP |
2. Calculate Function Points for Each Type
Given:
- 25 External Inputs (EI) with Average complexity
- 20 External Outputs (EO) with High complexity
- 5 External Inquiries (EQ) with Low complexity
- 8 Internal Logical Files (ILF) with Average complexity
- 7 External Interface Files (EIF) with Low complexity
Calculations:
-
External Inputs (EI):
[
25 , \text{EI} \times 4 , \text{FP (Average)} = 100 , \text{FP}
]
-
External Outputs (EO):
[
20 , \text{EO} \times 7 , \text{FP (High)} = 140 , \text{FP}
]
-
External Inquiries (EQ):
[
5 , \text{EQ} \times 3 , \text{FP (Low)} = 15 , \text{FP}
]
-
Internal Logical Files (ILF):
[
8 , \text{ILF} \times 10 , \text{FP (Average)} = 80 , \text{FP}
]
-
External Interface Files (EIF):
[
7 , \text{EIF} \times 5 , \text{FP (Low)} = 35 , \text{FP}
]
Total Unadjusted Function Points (UFP):
[
100 + 140 + 15 + 80 + 35 = 370 , \text{FP}
]
Step 2: Calculate the Value Adjustment Factor (VAF)
The Value Adjustment Factor (VAF) accounts for 14 General System Characteristics (GSCs), each rated on a scale from 0 (No Influence) to 5 (Strong Influence). The formula for VAF is:
[
\text{VAF} = 0.65 + (0.01 \times \text{Total Degree of Influence (TDI)})
]
1. Determine Ratings for Each GSC
Based on the provided system requirements:
- Average conversion and installation in design → Installation Ease: Average → Rating = 3
- Essential distributed processing functions → Distributed Data Processing: Essential → Rating = 4
- Significantly critical performance → Performance: High → Rating = 5
- Moderate code reusability → Reusability: Moderate → Rating = 3
- Moderate data communication → Data Communications: Moderate → Rating = 3
The remaining 9 GSCs are assumed to be Average, each with a Rating = 3.
2. List of GSC Ratings
| GSC | Rating |
|---|
| Data Communications | 3 |
| Distributed Data Processing | 4 |
| Performance | 5 |
| Heavily Used Configuration | 3 |
| Transaction Rate | 3 |
| On-Line Data Entry | 3 |
| End-User Efficiency | 3 |
| On-Line Update | 3 |
| Complex Processing | 3 |
| Reusability | 3 |
| Installation Ease | 3 |
| Operational Ease | 3 |
| Multiple Sites | 3 |
| Facilitate Change | 3 |
Total Degree of Influence (TDI):
[
3 + 4 + 5 + 3 + 3 + 3 + 3 + 3 + 3 + 3 + 3 + 3 + 3 + 3 = 42
]
3. Calculate VAF
[
\text{VAF} = 0.65 + (0.01 \times 42) = 0.65 + 0.42 = 1.07
]
Step 3: Compute Adjusted Function Points (AFP)
[
\text{AFP} = \text{UFP} \times \text{VAF} = 370 , \text{FP} \times 1.07 = 395.9 , \text{FP}
]
Rounded to the nearest whole number:
[
\text{AFP} \approx 396 , \text{Function Points}
]
Final Function Point Count (FPC): 396 FP