transform this text in a proffession way Supply and Installation of Clinical Chemistry…
- User
transform this text in a proffession way Supply and Installation of Clinical Chemistry Autoanalyser machine , and training of the users at Kiziba campThe required biochemistry analyzer should meet the following:
- Analyzer with the greatest potential in the category, ideal for daily routine and special routine.
- Use of interface
- The analyzer must ensure up to 200 tests/hour, for clinical chemistry and turbidimetry; system reagents methods preinstalled and validated.
- Permits to create different profiles, like general, pre-operation, post-operation, hepatic, renal and metabolic.
- Remote diagnostic control that allows service staff to resolve errors quickly and efficiently without an on-site visit.
TECHNICAL DATA: a. Analysis Methods - Endpoint (Bichromatic-Differantial-Sample blank), Kinetics, Fixed-Time, Turbidimetry Calibration Curve - Linear, Non-Linear, Cubic - Spline, Multi Point. b. Sample Positions: configuration with 80 sample positions. c. Sample volume, 2-45 uL d. Automatic sample Dilution: pre dilution and post dilution e. Liquid level detection, vertical collision f. internal barcode reader (option) The analyzer must be Fully automated (automatic), used for clinical diagnostic, Configuration:benchtop, compact, Technology: random access, Sample type :urine, plasma, serum, Options: with barcode reader, Throughput:200 tests / hour, Sample volume: Max.: 0.3 ml (0.010144 US fl oz), Min.: 0.002 ml, (0.000068 US fl oz), Number of sample positions: 20 unit, Reagent volume:Max.: 0.35 ml (0.01 US fl oz) Min.: 0 ml (0 US fl oz), Number of reagent positions20 unit
- Assistant
- User
Supply and Installation of Clinical Chemistry Autoanalyser machine , and training of the users at Kiziba campThe required biochemistry analyzer should meet the following:
- Analyzer with the greatest potential in the category, ideal for daily routine and special routine.
- Use of interface
- The analyzer must ensure up to 200 tests/hour, for clinical chemistry and turbidimetry; system reagents methods preinstalled and validated.
- Permits to create different profiles, like general, pre-operation, post-operation, hepatic, renal and metabolic.
- Remote diagnostic control that allows service staff to resolve errors quickly and efficiently without an on-site visit.
TECHNICAL DATA: a. Analysis Methods - Endpoint (Bichromatic-Differantial-Sample blank), Kinetics, Fixed-Time, Turbidimetry Calibration Curve - Linear, Non-Linear, Cubic - Spline, Multi Point. b. Sample Positions: configuration with 80 sample positions. c. Sample volume, 2-45 uL d. Automatic sample Dilution: pre dilution and post dilution e. Liquid level detection, vertical collision f. internal barcode reader (option) The analyzer must be Fully automated (automatic), used for clinical diagnostic, Configuration:benchtop, compact, Technology: random access, Sample type :urine, plasma, serum, Options: with barcode reader, Throughput:200 tests / hour, Sample volume: Max.: 0.3 ml (0.010144 US fl oz), Min.: 0.002 ml, (0.000068 US fl oz), Number of sample positions: 20 unit, Reagent volume:Max.: 0.35 ml (0.01 US fl oz) Min.: 0 ml (0 US fl oz), Number of reagent positions20 unit
- Assistant