// method can be called twice every cycle: from application AND…
- User
// method can be called twice every cycle: from application AND MTL_Node.cyclic()->_errorHandler()->error() IF (THIS^.diCurrTaskIndex = 0) THEN THIS^.diCurrTaskIndex := Tc2_System.GETCURTASKINDEXEX(); // get current task index END_IF IF (THIS^.diCurrTaskIndex > 0) THEN THIS^.udiRefCycleCount REF=TwinCAT_SystemInfoVarList._TaskInfo[THIS^.diCurrTaskIndex].CycleCount; IF (THIS^.udiCycleCountOld <> THIS^.udiRefCycleCount) THEN // first call in this task-cycle ->continue THIS^.udiCycleCountOld := THIS^.udiRefCycleCount; // safe current value ELSE // 2. call in this task-cycle IF (xSavedCondition = xCondition) THEN // input not changed in 2. call in same task-cycle -> nothing more to do // need to set output IF (udiAssertStep = 0) THEN // error was active and now quitted in this task-cycle in previous call assert := FALSE; ELSE // all other steps: error is active assert := TRUE; END_IF RETURN; // -> go out ELSE // proceed: input-value has changed and needs to be processed END_IF END_IF END_IF
// check once if provided values are valid IF (THIS^.eAlarmClassOld <> THIS^.eClass) AND (xCondition) THEN CASE eClass OF PopUpMessage, PopUpMessage_NoAck, Message, Message_NoAck, PopUpWarning, PopUpWarning_NoAck, Warning, Warning_NoAck, Alarm, Alarm_SingleAck: // do nothing: eAlarmClass is valid ELSE SUPER^.logmsg(MTL_eLogLevel.ERROR, tc2_Standard.CONCAT('Application-Error: Unsupported value for ErrorClass: 0x', DWORD_TO_HEXSTR(DINT_TO_DWORD(eClass),1,FALSE))); END_CASE IF (THIS^.udiError = 0) THEN sTmp := Tc2_Utilities.F_ToUCase(SUPER^.Name); IF (0 = Tc2_Standard.FIND(sTmp, GVL_Error.gc_sMtlSystem)) THEN SUPER^.logmsg(MTL_eLogLevel.WARNING , 'Application-Error: udiError not set. Errornumber can not be queried / active error can not be identified.'); END_IF sTmp := ''; END_IF CASE eStopMode OF MTL_eStopMode.None, MTL_eStopMode.Cancel, MTL_eStopMode.Abort, MTL_eStopMode.Stop, MTL_eStopMode.Pause: // do nothing: eStopMode is valid ELSE SUPER^.logmsg(MTL_eLogLevel.ERROR, 'Application-Error: no valid StopMode set'); END_CASE CASE dwLightTowerClass OF MTL_eLightTower.OFF, NO_PRODUCTION, PRODUCTION, LOGIC_WARNING, PROCESS_WARNING, STATION_ALARM, QUALITY_ALARM, QUALITY_STOPP: // do nothing: dwLightTowerClass is valid ELSE SUPER^.logmsg(MTL_eLogLevel.ERROR, 'Application-Error: no valid LigthTowerClass set'); END_CASE IF (sInfo = '') THEN SUPER^.logmsg(MTL_eLogLevel.WARNING, 'Application-Error: sInfo not set. No info-logmessage will be generated when error is active.'); END_IF THIS^.eAlarmClassOld := THIS^.eClass; END_IF
// store condition for asynchron handling xSavedCondition := xCondition;
CASE udiAssertStep OF 0: // wait for error // node is deactivated and no new error is allowed to be set. // check is done in this place since existing/active errors must be reset/released (at the time when node is deactivated) IF THIS^.xDeactivated THEN RETURN; END_IF
IF xCondition THEN xQuit := FALSE; xActive := TRUE; // signal SCADA system error is active xError := TRUE; // signal to errorhandler error is active xResetError := FALSE; // remove reset request // get stop mode text for log message CASE eStopMode OF MTL_eStopMode.Cancel: sTmp := ' (StopMode: Cancel)'; MTL_eStopMode.Abort: sTmp := ' (StopMode: Abort)'; MTL_eStopMode.Stop: sTmp := ' (StopMode: Stop)'; END_CASE logmsg(MTL_eLogLevel.MESSAGE, Tc2_Standard.CONCAT(sInfo, sTmp)); THIS^.itfMtlError.mNewErrorActive(); GVL_Error.errorList.addToList(sInfo, name, eClass); itfMesError := THIS^.itfMtlError.mGetMesHandler(); // this might have been added later from application IF (itfMesError <> 0) AND (stMesError.udiErrorId <> 0) THEN itfMesError.mSendError(xActive := TRUE, udiMesErrorId := stMesError.udiErrorId, eMesErrorClass := stMesError.eClass, sMesErrorText := stMesError.sText, sMTLErrorText := 'MtlError'); END_IF THIS^.xSCADAConfigured := THIS^.itfMtlError.mSCADAExists(); // set actual status THIS^.tActivationTime := TIME(); // store starting time THIS^.tDuration := T#0S; // clear out old value udiAssertStep := 20; END_IF assert := xCondition; 1: // condition reappeared xQuit := FALSE; xActive := TRUE; // signal SCADA system error is active xError := TRUE; // signal to errorhandler error is active xResetError := FALSE; // remove reset request logmsg(MTL_eLogLevel.MESSAGE, Tc2_Standard.CONCAT(sInfo, ' (Condition reappeared)')); udiAssertStep := 20; assert := TRUE; 20: // wait for confirmation from SCADA / stay in step if error is in SCADA not browsed (and generate a logmessage) THIS^.xSCADAConfigured := THIS^.itfMtlError.mSCADAExists(); // set actual status IF (NOT THIS^.xSCADAConfigured) OR ((DINT_TO_DWORD(eClass) AND GVL_Error.NOACK_BIT) = GVL_Error.NOACK_BIT) THEN udiAssertStep := 30; ELSE // SCADA is configured: waiting for reaction from SCADA in bState (if error is browsed) IF (bState = MTL_eAlarmState.ACTIVE) OR (bState = MTL_eAlarmState.ACTIVE_BUT_QUIT) THEN IF xLogMsgSend THEN SUPER^.logmsg(MTL_eLogLevel.WARNING, 'SCADA is connected and handles the error'); xLogMsgSend := FALSE; END_IF xPlcRestarted := FALSE; udiAssertStep := 30; ELSIF (bState = MTL_eAlarmState.SCADA_NOT_HANDLED) THEN // No reaction from SCADA==> STAY FOREVER in this state if no reaction is seen from SCADA !!! THIS^.xScadaIsConnected := THIS^.itfMtlError.mSCADAIsConnected(); IF (THIS^.xScadaIsConnected) THEN // wait until SCADA is connected -> if error is browsed the bState will be changed IF (NOT xLogMsgSend) THEN // generate logmessage only once tonWaitForScada(PT := T#1S, IN := TRUE); // start timer to check if SCADA reacts => detection if MTL_fbError is browsed in SCADEA IF (tonWaitForScada.Q) THEN // timer expired => no change from SCADA => error not browsed IF (NOT xPlcRestarted) THEN SUPER^.logmsg(MTL_eLogLevel.ERROR, 'Application Error: Error is not browsed in SCADA!! Error is NOT quit (continiously active) !!!'); xLogMsgSend := TRUE; // prevent multiple errorlogmessages ELSE xPlcRestarted := FALSE; xActive := FALSE; udiAssertStep := 21; END_IF tonWaitForScada(IN := FALSE); END_IF END_IF END_IF END_IF END_IF assert := TRUE; 21: // try to get back the visiwin manager connection tonWaitForScada(PT := T#1S, IN := TRUE); IF (bState <> MTL_eAlarmState.SCADA_NOT_HANDLED) OR (tonWaitForScada.Q) THEN tonWaitForScada(IN := FALSE); xActive := TRUE; udiAssertStep := 20; END_IF assert := TRUE; 30: // wait until condition is gone IF NOT xCondition THEN udiAssertStep := 40; xActive := FALSE; xQuit := FALSE; END_IF assert := TRUE; 40: // wait until SCADA has handled error // condition appears again -> start from the beginning IF xCondition THEN IF THIS^.xDeactivated THEN udiAssertStep := 50; // go out: node is deactivated and error does not need to be active any longer. ELSE udiAssertStep := 1; END_IF END_IF IF ((DINT_TO_DWORD(eClass) AND GVL_Error.NOACK_BIT) = GVL_Error.NOACK_BIT) THEN udiAssertStep := 50; ELSE IF xSCADAConfigured THEN IF bState = MTL_eAlarmState.ACTIVE OR bState = MTL_eAlarmState.REACTIVATED OR bState = MTL_eAlarmState.GONE_WITHOUT_QUIT OR bState = MTL_eAlarmState.ACTIVE_BUT_QUIT OR bState = MTL_eAlarmState.GONE_WITH_QUIT THEN ; ELSIF (bState = MTL_eAlarmState.NO_ACTIVE) THEN udiAssertStep := 50; ELSE logmsg(MTL_eLogLevel.WARNING, tc2_standard.CONCAT('Unexpected error state in assert method! value: ', BYTE_TO_STRING(bState)) ); udiAssertStep := 50; END_IF ELSE IF (xQuit) OR (NOT xCondition) THEN udiAssertStep := 50; END_IF END_IF END_IF assert := TRUE; 50: // the final state xError := FALSE; // error is handled assert := FALSE; // every thing is fine xQuit := FALSE; // reset xQuit flag xResetError := FALSE; // reset reset flag THIS^.itfMtlError.mErrorQuit(); GVL_Error.errorList.removeFromList(name); itfMesError := THIS^.itfMtlError.mGetMesHandler(); IF (itfMesError <> 0) AND (stMesError.udiErrorId <> 0) THEN itfMesError.mSendError(xActive := FALSE, udiMesErrorId := stMesError.udiErrorId, eMesErrorClass := stMesError.eClass, sMesErrorText := stMesError.sText, sMTLErrorText := 'MtlError'); END_IF THIS^.tDuration := TIME() - THIS^.tActivationTime; // IF ((THIS^.eClass = MTL_eAlarmClass.Alarm) OR (THIS^.eClass = MTL_eAlarmClass.Alarm_SingleAck)) THEN SUPER^.logmsg(MTL_eLogLevel.MESSAGE, tc2_Standard.CONCAT('finished alarm-handling. Duration: ', TIME_TO_STRING(THIS^.tDuration)) ); ELSE SUPER^.logmsg(MTL_eLogLevel.TRACE, tc2_Standard.CONCAT('finished handling', TIME_TO_STRING(THIS^.tDuration)) ); END_IF // start from the begining THIS^.udiAssertStep := 0; ELSE THIS^.udiAssertStep := 0; - Assistant
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.