To solve the given problem, we'll determine:
(i) The field current ( I_f ).
(ii) The firing angle ( \alpha ) of the converter in the armature circuit.
Part (i): Finding the Field Current ( I_f )
The field circuit is supplied by a single-phase half-controlled bridge rectifier (a semi-converter), set to provide the maximum possible field current. The output voltage ( V_{dc} ) of such a converter when the firing angle ( \alpha = 0^\circ ) is:
[
V_{dc_max} = \frac{2V_m}{\pi}
]
where ( V_m ) is the peak value of the input AC voltage. For an RMS AC supply voltage ( V_{rms} = 230 , \text{V} ), the peak voltage is:
[
V_m = \sqrt{2} V_{rms} = \sqrt{2} \times 230 , \text{V} \approx 325.27 , \text{V}
]
Thus, the maximum DC voltage is:
[
V_{dc_max} = \frac{2 \times 325.27}{\pi} , \text{V} \approx \frac{650.54}{3.1416} , \text{V} \approx 207.08 , \text{V}
]
Now, the field current ( I_f ) is calculated using Ohm’s Law:
[
I_f = \frac{V_{dc_max}}{R_f} = \frac{207.08}{104} , \text{A} \approx 1.99 , \text{A}
]
Thus, the field current is approximately ( 1.99 , \text{A} ).
Answer to Part (i): The field current ( I_f \approx 1.99 , \text{A} ).
Part (ii): Finding the Firing Angle ( \alpha ) in the Armature Circuit
First, we find the armature current ( I_a ) using the torque equation for a DC motor:
[
T = K_t \times I_a
]
Given that ( K_t ) (the torque constant) equals ( K_a ) (the back EMF constant) when using SI units. We have:
[
T = K_a \times I_a
]
Given:
- Torque ( T = 50 , \text{N}\cdot\text{m} )
- ( K_a = 0.9 , \text{V}\cdot\text{s/rad} )
Rearranged:
[
I_a = \frac{T}{K_a} = \frac{50}{0.9} , \text{A} \approx 55.56 , \text{A}
]
Now, we calculate the motor speed in radians per second (( \omega_m )):
[
\omega_m = \text{RPM} \times \frac{2\pi}{60} = 800 \times \frac{2\pi}{60} , \text{rad/s} = \frac{80\pi}{3} , \text{rad/s} \approx 251.33 , \text{rad/s}
]
Next, compute the back EMF (( E_b )):
[
E_b = K_a \times \omega_m = 0.9 \times 251.33 , \text{V} \approx 226.20 , \text{V}
]
Now, calculate the required average DC voltage ( V_{dc} ) at the armature terminals accounting for voltage drops across the armature resistance (( R_a = 0.3 , \Omega )):
[
V_{dc} = E_b + I_a R_a = 226.20 + 55.56 \times 0.3 , \text{V} = 226.20 + 16.67 , \text{V} \approx 242.87 , \text{V}
]
Next, find the firing angle ( \alpha ) of the converter supplying the armature. For a single-phase half-controlled bridge rectifier, the average output voltage is:
[
V_{dc} = \frac{V_m}{\pi}(1 + \cos{\alpha})
]
Substituting the known values (( V_m = 325.27 , \text{V} )):
[
242.87 = \frac{325.27}{\pi}(1 + \cos{\alpha}) \implies 242.87 = 103.66(1 + \cos{\alpha})
]
Solving for ( \cos{\alpha} ):
[
1 + \cos{\alpha} = \frac{242.87}{103.66} \implies \cos{\alpha} = \frac{242.87}{103.66} - 1 \approx 2.344 - 1 = 1.344
]
However, ( \cos{\alpha} ) cannot exceed 1, indicating that the required DC voltage is unattainable with this configuration and supply voltage.
Conclusion: The required armature voltage exceeds the maximum output voltage possible from a single-phase half-controlled converter supplied from a 230 V AC source. Hence, the converter must be set to its maximum output voltage, which corresponds to a firing angle ( \alpha = 0^\circ ).
Answer to Part (ii): The firing angle of the converter in the armature circuit is ( \alpha = 0^\circ ).
Answers:
-
The field current is approximately 1.99 A.
-
The firing angle of the armature converter is zero degrees; that is, α = 0°.