correct the grammar: Attached here is the email thread of the inspection report of Engr.…
- User
correct the grammar: Attached here is the email thread of the inspection report of Engr. Greg Lanuza, As seen in the unit during inspection and had monitored by the engineering staff, it was witnessed that the AC unit was leaking after it was opened even for a short period of time. This indicates possibilities such as the following:
- Assistant
Attached here is the email thread of the inspection report by Engr. Greg Lanuza. As observed during the inspection and monitored by the engineering staff, it was noted that the AC unit was leaking even after being opened for a short period of time. This indicates the following possibilities:
- User
correct the grammar: 1. Lack of maintenance - build up sludge may have been blocking the condensed water drainage causing it to leak every time the AC unit are being used.
- Assistant
- Lack of maintenance - A buildup of sludge may be blocking the condensed water drainage, causing it to leak every time the AC unit is used.
- User
correct the grammar: 2. Improper maintenance - may be timely cleaned by cleaning team but not doing it properly, resulting of accumulated dirt on the drainage pipe.
- Assistant
- Improper maintenance - The unit may be cleaned regularly by the maintenance team, but if it is not done properly, it can result in accumulated dirt in the drainage pipe.
- User
correct the grammar: 3. Capillary tube clogging - this Phenomena is common for a AC unit that is either not been clean properly or a not enough refrigerant in the system due to leak.
- Assistant
- Capillary tube clogging - This phenomenon is common in an AC unit that either has not been cleaned properly or does not have enough refrigerant in the system due to a leak.
- User
correct the grammar: 4. Improper installation height of the indoor unit - This happened when the indoor unit is installed lower than the drain provision of the condo unit. Typically, if this happened, its either one have to install a drain pump or correct the indoor unit installation height.
- Assistant
- Improper installation height of the indoor unit - This occurs when the indoor unit is installed lower than the drain provision of the condo unit. Typically, if this happens, one either has to install a drain pump or correct the indoor unit's installation height.
- User
correct the grammar: Regardless of the reason why the AC has been leaking, its still the responsibility of the resident to be mindful of not using it while its still leaking, since we are living in a condominium that may affect the other units with negligence like this. As attached in email report, it has been observed t hat the AC unit were continuously used despite leaking hardly.
- Assistant
Regardless of the reason why the AC has been leaking, it is still the responsibility of the resident to avoid using it while it is still leaking. Living in a condominium means that negligence like this could affect other units. As noted in the attached email report, it has been observed that the AC unit was continuously used despite significant leaking.
- User
correct the grammar: As noted in the attached email report, it has been observed that the AC unit was continuously used by the resident despite significant leaking hence the damages in the lower unit has accumulated.
- Assistant
As noted in the attached email report, it has been observed that the AC unit was continuously used by the resident despite significant leaking. As a result, the damages in the lower unit have accumulated.
- User
correct the grammar: The Documents sent her in the office are all well received. Please see below lists for the remaining documents for your application to be submit.
- Assistant
The documents sent to the office have all been received. Please see the list below for the remaining documents to be submitted for your application.
- User
correct the grammar: Additionally, since the root caused of the damages in the lower unit was the negligence of the previous resident of unit 8K-EW (continuously using the AC despite significant leaking). There will no possibility that this may be accepted with insurance claim.
- Assistant
Additionally, since the root cause of the damages in the lower unit was the negligence of the previous resident of unit 8K-EW (continuously using the AC despite significant leaking), there is no possibility that this may be accepted as an insurance claim.