The AFE section is a 1:1 datasheet copy and I’ve included the charge / discharge…
- User
The AFE section is a 1:1 datasheet copy and I’ve included the charge / discharge mosfets. I had an unpleasant surprise, but I was somehow expecting it: when you close the CHG fet for example, It’s internal diode is still there – you’ll have to close both FET’s at once. Another annoying thing is the way the communication CRC works when you try to read a block of data – you don’t get one CRC at the end, you get a CRC byte after each data byte The REGOUT 3.3V output is used as an enable signal for the 3.3V buck converter to keep the entire AFE board in the lowers power mode when the chip is in “shipping” mode ne demek istemiş bana açıkla
- Assistant
Elindeki metinde birkaç teknik detay ve karşılaşılan zorluklar anlatılmış. İşte ne demek istendiği:
-
AFE Bölümü:
- "AFE section is a 1:1 datasheet copy": Bu, AFE (Analog Front End) bölümünün doğrudan datasheet'ten kopyalandığını belirtiyor. Yani veriler orijinal teknik dökümandan değiştirilmeden alınmış.
-
Şarj / Deşarj MOSFET'leri:
- "Charge / discharge MOSFETs included": Şarj ve deşarj MOSFET'lerinin devreye dahil edildiği belirtiliyor.
-
MOSFET'lerin Kullanımıyla İlgili Sorunlar:
- "when you close the CHG fet...": Şarj MOSFET'ini kapattığınızda, bu MOSFET'in iç diyotunun hala devrede olduğunu belirtiyor. Yani sadece şarj MOSFET'ini kapatmanız yeterli olmayabilir, hem şarj hem de deşarj MOSFET'lerini aynı anda kapatmanız gerekebilir.
-
- User
n mosfet ile p mosfet arasındaki farklar nelerdir
- Assistant
N-MOSFET (N-channel Metal-Oxide-Semiconductor Field-Effect Transistor) ve P-MOSFET (P-channel Metal-Oxide-Semiconductor Field-Effect Transistor) arasında birkaç temel fark vardır. İşte bu farklar:
-
:
-
- User
- Assistant
- User
The bq769x0 is not a standalone protector and will require a host. The bq769x0 AFE will measure voltages and monitor voltage faults based on those voltages as well as monitor current faults. However, a host is required to set the registers for the protection thresholds and to turn on FET control outputs. If current measurement is desired, the host must read the values from the AFE. When faults occur, the host must clear the faults and recover when appropriate. While the AFE could be set and left to operate unsupervised, a fault would leave the battery disabled. The selection of the host will influence the appropriate AFE version. The bq78350 is a gauge designed to control the bq769x0 AFE. It has pre-programmed behavior determined by the selection of available parameters. Protection limits can be set in the firmware. The gauging uses a Compensated End of Discharge Voltage (CEDV) algorithm which uses coefficients calculated from data collection runs with the pack design. Communication to the gauge is through SMBus. The gauge handles all communication to the AFE and does not share the I2C bus to the AFE or allow modification of the AFE registers. The bq78350 is a 2.5-V device and at its initial release supports the -00 and -01 2.5-V output AFEs, be sure to check the latest bq78350 information for options supported. A customer provided MCU can be used with the AFE. This allows the MCU programming to provide special system behaviors for the battery. The MCU must set the protection registers, enable FETs, recover from faults, and provide a balancing algorithm, if desired. The MCU can implement a gauging algorithm and provide display or communication appropriate for the battery system. In addition to the cell voltage readings from the AFE the MCU may measure battery voltage for a real-time calibration as described in the bq769x0 datasheet and pack voltage, if desired. Any of the bq769x0 device options may be used as appropriate for the MCU. Related to the MCU is the selection of a boot method for the AFE. The bq769x0 datasheet shows a simple concept of using a switch to boot the device when ready. If the MCU is powered from a separate regulator, it can put the AFE to sleep and boot the AFE as desired. With the bq78350, a circuit to provide a pulse is needed to boot the AFE and start the bq78350. bana açıkla
- Assistant
- User
The bq769x0 is not a standalone protector and will require a host. The bq769x0 AFE will measure voltages and monitor voltage faults based on those voltages as well as monitor current faults. However, a host is required to set the registers for the protection thresholds and to turn on FET control outputs. If current measurement is desired, the host must read the values from the AFE. When faults occur, the host must clear the faults and recover when appropriate. While the AFE could be set and left to operate unsupervised, a fault would leave the battery disabled. The selection of the host will influence the appropriate AFE version. The bq78350 is a gauge designed to control the bq769x0 AFE. It has pre-programmed behavior determined by the selection of available parameters. Protection limits can be set in the firmware. The gauging uses a Compensated End of Discharge Voltage (CEDV) algorithm which uses coefficients calculated from data collection runs with the pack design. Communication to the gauge is through SMBus. The gauge handles all communication to the AFE and does not share the I2C bus to the AFE or allow modification of the AFE registers. The bq78350 is a 2.5-V device and at its initial release supports the -00 and -01 2.5-V output AFEs, be sure to check the latest bq78350 information for options supported. A customer provided MCU can be used with the AFE. This allows the MCU programming to provide special system behaviors for the battery. The MCU must set the protection registers, enable FETs, recover from faults, and provide a balancing algorithm, if desired. The MCU can implement a gauging algorithm and provide display or communication appropriate for the battery system. In addition to the cell voltage readings from the AFE the MCU may measure battery voltage for a real-time calibration as described in the bq769x0 datasheet and pack voltage, if desired. Any of the bq769x0 device options may be used as appropriate for the MCU. Related to the MCU is the selection of a boot method for the AFE. The bq769x0 datasheet shows a simple concept of using a switch to boot the device when ready. If the MCU is powered from a separate regulator, it can put the AFE to sleep and boot the AFE as desired. With the bq78350, a circuit to provide a pulse is needed to boot the AFE and start the bq78350. bana açıkla ne demek istemiş bana açıkla
- Assistant
- User
The bq769x0 devices have internal balance FETs controlled by the host through registers. When enabled, the internal FET will pull the pins associated with that cell together drawing current through the input resistors for that cell. For the bq76920 the input resistors can be sized to select the balance current within the capability of the part. For the bq76930 and bq76940, the input filter resistors must be large due to the device architecture, so internal balance current is limited in these family members
- Assistant
BQ769x0 serisi cihazlar, ana kontrolcü (host) tarafından registerlar üzerinden kontrol edilen dahili dengeleme FET'lerine sahiptir. Bu FET'ler etkinleştirildiğinde, ilgili hücrenin pinlerini birbirine çekerek bu hücre için giriş dirençleri aracılığıyla akım çekerler.
Cihazlara Göre Detaylar:
-
BQ76920:
- Giriş Dirençleri: Bu cihazda, giriş dirençlerinin boyutu dengeleme akımını belirlemek için ayarlanabilir. Yani, dengeleme akımını seçmek için dirençleri istenilen değerde seçebilirsiniz.
-
BQ76930 ve BQ76940:
- Giriş Filtre Dirençleri: Bu cihazlarda, cihaz mimarisi nedeniyle giriş filtre dirençleri büyük olmalıdır. Bu, bu aile üyelerindeki dahili dengeleme akımının sınırlı olduğu anlamına gelir.
Özet:
- Dahili Balance FET'ler: BQ769x0 serisi cihazlar, dengeleme amacıyla ana kontrolcü tarafından kontrol edilen dahili dengeleme FET'lerine sahiptir.
-
- User
The 250 ms measurement timeline is divided into 12.5 ms intervals. When balancing, the balance FET is enabled for 14 of the 20 intervals. The balance FET is turned off for one interval before measurement starts on the bottom cell of the group. The cells are then measured in sequence. The input filter must settle within the 12.5 ms or there will be voltage error in the cell measurement. Since the cells are measured in sequence, the bottom cells will show the largest influence. The more cells are balanced, the more time will be required for the filter to settle. For the bq76920, the Rc input resistors are adjusted for the balance current and are typically in the smaller values of the datasheet range, and the Cc filter capacitors can generally be large. For the bq76930 and bq76940 the input resistors are large and the Cc capacitors may be smaller for improved measurement.
- Assistant
Bu metin, BQ769x0 serisi cihazlarda dengeleme işlemi ve hücre ölçüm sırası hakkında bilgi vermektedir. İşte ayrıntılı Türkçe açıklaması:
Genel Bilgiler:
- Ölçüm Zaman Çizelgesi (250 ms): Ölçüm süresi 250 ms'dir ve bu süre 12.5 ms'lük aralıklara bölünmüştür.
Dengeleme FET'leri:
- Dengeleme FET'lerinin Çalışması:
- User
Since the cell inputs pull together during balancing, care must be used to prevent damage to the inputs. If all cells in a group are enabled to balance at the same time, the inputs will pull together and some of the maximum limits will be exceeded, the part is likely to be damaged. Balancing every other cell in a group will double the voltage on the unbalanced cell and is typically OK, check the voltage limits for the cell voltages used in your design.
- Assistant
Metin, hücre dengeleme işlemi sırasında hücre girişlerini korumak ve hasar önlemek için dikkat edilmesi gerekenleri açıklamaktadır. İşte detayları:
Hücre Dengeleme Sırasında Dikkat Edilmesi Gerekenler:
-
Hücre Girişlerinin Çekilmesi:
- Birlikte Çekilme: Dengeleme sırasında hücre girişleri birlikte çekilir (birbirine bağlanır). Bu, girişlerin zarar görmemesi için dikkatli olunması gerektiği anlamına gelir.
-
Aynı Anda Dengeleme:
-
- User
External cell balancing can be used with the bq769x0 family. An external FET is switched to draw current from the cell through a resistor. Control for the FET comes from the voltage across one of the Rc input resistors. When P-channel balance FETs are used the upper resistor is used, see Figure 5. When Nchannel balance FETs are used, the lower resistor is used, see Figure 6. A FET with a defined RDS(ON) at approximately ½ the cell voltage is desired. These FETs will typically have a low maximum VGS, so the gate voltage will usually need to be protected by a zener diode. The gate voltage should be connected through a resistor to limit the current when the diode conducts. During normal operation the zener will not conduct. During a heavy load event such as a short circuit, the cell inputs will drop near battery- while the IC VCn pins will initially be at their normal voltage as shown in Figure 7. The zener diodes will prevent the high voltage from reaching the gate and most of the input resistor voltage will be dropped across the gate resistor. The gate resistor current will contribute to the drop of the Cf capacitor voltage, so the gate resistors should be large. When the short circuit is released, the voltage will reverse on the input filter resistors and gate protection zeners will conduct in the opposite direction.
- Assistant