"• The battery will be placed in the most ideal way in terms of distance and direction…
- User
"• The battery will be placed in the most ideal way in terms of distance and direction from other auxiliary equipment for testing. • Since the table surfaces where the battery is placed are always grounded conductive surfaces, it should be checked that the battery is also grounded. • The cable bundle should run in a straight line on the table from the battery to the auxiliary equipment, keeping the specified distance between the cables as per the standard. • There is a 5 cm thick insulation sponge or similar material between the wiring and the table. • In anechoic chamber tests, cabling should be passed through the flange or hole interface in the chamber wall. However, the portions outside the chamber should be properly grounded. • Cabling and auxiliary equipment used outside the chamber (such as power supply, load, computer, control interfaces, and cables) shall be grounded." Bu cümleyi test prosedür dokumanına uygun şekilde "emir" talimat şekline çevir.
- Assistant
• Bataryayı, diğer yardımcı ekipmanlarla aradaki mesafe ve yön açısından en ideal şekilde yerleştiriniz. • Bataryanın konulacağı masa yüzeyleri her zaman topraklanmış iletken yüzeyler olduğundan, bataryanın da topraklanmış olduğunu kontrol ediniz. • Kablo demetinin, standartlara uygun belirtilen mesafeyi koruyarak, bataryadan yardımcı ekipmana doğru masa üzerinde düz bir hat üzerinde gitmesini sağlayınız. • Kablolar ile masa arasında 5 cm kalınlığında bir yalıtım süngeri veya benzer bir malzeme bulundurunuz. • Yankısız oda testlerinde kabloları, odanın duvarındaki flanş veya delik arayüzünden geçiriniz. Ancak, odanın dışındaki bölümleri düzgün bir şekilde topraklayınız. • Yankısız odanın dışında kullanılan kablolama ve yardımcı ekipmanları (güç kaynağı, yük, bilgisayar, kontrol arayüzleri ve kablolar gibi) topraklayınız.
- User
“• The battery will be placed in the most ideal way in terms of distance and direction from other auxiliary equipment for testing. • Since the table surfaces where the battery is placed are always grounded conductive surfaces, it should be checked that the battery is also grounded. • The cable bundle should run in a straight line on the table from the battery to the auxiliary equipment, keeping the specified distance between the cables as per the standard. • There is a 5 cm thick insulation sponge or similar material between the wiring and the table. • In anechoic chamber tests, cabling should be passed through the flange or hole interface in the chamber wall. However, the portions outside the chamber should be properly grounded. • Cabling and auxiliary equipment used outside the chamber (such as power supply, load, computer, control interfaces, and cables) shall be grounded.” Bu cümleyi ingilizce olarak test prosedür dokumanına uygun şekilde “emir” talimat şekline çevir.
- Assistant
• Place the battery in the most ideal way in terms of distance and direction from other auxiliary equipment for testing. • Check that the battery is also grounded, as the table surfaces where the battery is placed are always grounded conductive surfaces. • Run the cable bundle in a straight line on the table from the battery to the auxiliary equipment, keeping the specified distance between the cables as per the standard. • Ensure there is a 5 cm thick insulation sponge or similar material between the wiring and the table. • Pass the cabling through the flange or hole interface in the chamber wall during anechoic chamber tests. Ensure the portions outside the chamber are grounded properly. • Ground the cabling and auxiliary equipment used outside the chamber (such as power supply, load, computer, control interfaces, and cables).
- User
"Run the cable bundle in a straight line on the table from the battery to the auxiliary equipment, keeping the specified distance between the cables as per the standard." Run yerine farklı kelime kullan.
- Assistant
"Route the cable bundle in a straight line on the table from the battery to the auxiliary equipment, keeping the specified distance between the cables as per the standard."