    The following is the first draft of an academic paper of mine. Please help me polish the language.<Abstract: Geotextiles, as commonly used filter materials, have been widely used in emergency rescue of dike backward erosion pipe (BEP). However, the understanding of the filtration characteristics of geotextiles filter used in BEP emergency rescue is unclear, as a result, the selection of materials in engineering lacks adequate scientific basis. To investigate the filtration characteristics of geotextile in emergency rescue of dike BEP, several experiments with nonwoven and woven geotextiles were conducted to simulate the process of geotextile filtering boiled sand caused by BEP. The influence of specifications and weaving types of geotextile on hydraulic compatibility of filter system was analyzed, and the clogging mechanism of geotextile during handling BEP was revealed at a microscopic level. The results showed that the filtration performance of nonwoven geotextiles was better compared to woven geotextiles, and increasing the thickness and pore size of nonwoven geotextiles within a certain range helped enhance their anti-clogging ability. The main mechanism of clogging in nonwoven geotextiles was the deposition of fine sand particles on their surface, forming a layer of low permeability soil. The flat wire woven geotextile experienced severe clogging and were not suitable for BEP emergency rescue. The clogging mechanism of woven geotextile was that the horizontal water passages were blocked by fine particles. Keywords: Geotextiles; Filtration characteristics; Dike; Emergency rescue for piping

    1 Introduction Dikes play a vital role in the flood control system and have contributed significantly to protecting the lives and properties of coastal residents. Backward erosion piping (BEP) is an internal erosion mechanism that can destabilize dikes and embankments founded on a granular aquifer covered by a cohesive layer1. BEP occurs when a concentrated seepage flow towards a local disruption of the downstream top layer. Once a BEP incident occurs, timely emergency measures need to be taken to prevent the potential impact on the safety of dikes. If not addressed promptly, it may lead to dike collapse2,3. The most effective and commonly used method for BEP emergency response is to lay filtration materials at the water outlet of BEP, this method helps to prevent continuous erosion of sand particles. Geotextiles filter own advantages such as low cost, energy efficiency, environmental friendliness, easy construction, quick installation, and reliable quality compared to traditional filter materials like sand and gravel filter used for preventing BEP4-6. Geotextiles, as commonly used filter materials, have been widely applied in BEP emergency rescue7,8. To ensure optimal filtration performance of geotextiles, it is necessary to conduct research on their filtration characteristics in different engineering scenarios. Yadav et al.9 investigated the filtration properties of geotextiles when filtering air, while Liu et al.10 studied the filtration characteristics when filtering tailings. Odabasi et al.11 explored the filtration properties of geotextiles when filtering recycled materials such as recycled concrete aggregates. Limited studies12,13 have investigated the filtration characteristics of geotextiles used in BEP emergency rescue. Yan et al.12 performed simplified indoor experiments to qualitatively analyze filtration performance of different types of geosynthetic materials (geotextiles, geogrids, and geonet). Variable head conditions were used in the experiment, however, constant head conditions are more realistic hydraulic conditions. What’s more, quantitative analysis of permeability and clogging of the filter materials was not implemented. Zhang et al.13 conducted filtration experiment on geosynthetic materials under high water pressure conditions, simulating the process of BEP rescue of the Yellow River dike. The results indicated that needle-punched nonwoven geotextile with an equivalent aperture size of 0.2 mm and warp knitted woven geotextile with an equivalent aperture size of 0.352 mm were suitable for BEP emergency rescue on the Yellow River dike. The horizontal seepage conditions were simulated in the experiment, but the actual seepage direction was vertically upward. The filtration characteristics of geotextiles in BEP emergency rescue are affected by many factors such as soil gradation, geotextile pore size, and flow conditions. Currently, the relevant research is rare, and the micro-mechanisms of geotextile clogging in BEP emergency rescue are not well understood, leading to a lack of scientific criteria for selecting geotextiles. Although geosynthetic materials significantly improve the efficiency of BEP emergency measures, the challenge lies in the rational selection of geosynthetic materials that match the soil characteristics of dikes and hydraulic conditions. Therefore, there is an urgent need for research on the filtration characteristics of geotextiles in BEP emergency measures. BEP generally occurs in sandy soil layers of dike foundation. In this study, typical sandy soil from the Yangtze River dike was selected, and indoor experiments were conducted using an improved gradient ratio (GR) apparatus. The experiments focused on three different specifications of nonwoven geotextiles and one woven geotextile to examine their effectiveness in preventing BEP. The impact of pore size, thickness, and fabric weaving type of geotextile filter layers on their the soil-retention, clogging, and permeability properties was thoroughly analyzed. The distribution and morphology of clogging materials were investigated and the clogging mechanism of geotextiles used in BEP emergency rescue was revealed. This research aims to provide a scientific basis for the selection of geotextiles in BEP emergency rescue of dikes.>

  4. Assistant

    Abstract: Geotextiles are commonly used as filter materials in the emergency rescue of dike backward erosion pipes (BEP). However, there is a lack of understanding regarding the filtration characteristics of geotextiles used in BEP emergency rescue, resulting in a lack of scientific basis for material selection in engineering. To investigate the filtration characteristics of geotextiles in BEP emergency rescue, several experiments were conducted using nonwoven and woven geotextiles to simulate the filtration process of boiled sand caused by BEP. The influence of geotextile specifications and weaving types on hydraulic compatibility of the filter system was analyzed, and the clogging mechanism of geotextiles during BEP handling was revealed at a microscopic level. The results showed that nonwoven geotextiles had better filtration performance compared to woven geotextiles, and increasing the thickness and pore size of nonwoven geotextiles within a certain range enhanced their anti-clogging ability. The main mechanism of clogging in nonwoven geotextiles was the deposition of fine sand particles on their surface, forming a layer of low permeability soil. Flat wire woven geotextiles experienced severe clogging and were not suitable for BEP emergency rescue. The clogging mechanism of woven geotextiles involved the blocking of horizontal water passages by fine particles.

    Keywords: Geotextiles; Filtration characteristics; Dike; Emergency rescue for piping

    1. Introduction Dikes play a crucial role in flood control systems, protecting coastal residents' lives and properties. Backward erosion piping (BEP) is an internal erosion mechanism that can destabilize dikes and embankments founded on a granular aquifer covered by a cohesive layer. BEP occurs when concentrated seepage flow occurs towards a local disruption of the downstream top layer. Timely emergency measures are necessary to prevent potential impacts on dike safety in case of a BEP incident, as it can lead to dike collapse. The most commonly used method for BEP emergency response is laying filtration materials at the water outlet to prevent continuous erosion by sand particles. Geotextiles offer advantages such as low cost, energy efficiency, environmental friendliness, easy construction, quick installation, and reliable quality over traditional filter materials like sand and gravel. Therefore, geotextiles have been widely applied in BEP emergency rescue.

    To ensure optimal filtration performance of geotextiles, research on their filtration characteristics in different engineering scenarios is necessary. Previous studies have investigated the filtration properties of geotextiles in various contexts such as filtering air, tailings, and recycled materials. However, limited research has been conducted on the filtration characteristics of geotextiles used in BEP emergency rescue. Existing studies have mostly been qualitative, lacking quantitative analysis of permeability and clogging of filter materials. Additionally, the actual seepage direction in BEP emergency rescue is vertically upward, but previous experiments simulated horizontal seepage conditions. This research gap results in a lack of scientific criteria for selecting geotextiles and a need for further investigation into their filtration characteristics in BEP emergency measures.

    In this study, we focus on BEP occurring in sandy soil layers of dike foundations. Indoor experiments were conducted using an improved gradient ratio (GR) apparatus with typical sandy soil from the Yangtze River dike. The experiments examined three different specifications of nonwoven geotextiles and one woven geotextile to evaluate their effectiveness in preventing BEP. We thoroughly analyzed the impact of geotextile filter layers' pore size, thickness, and fabric weaving type on their soil-retention, clogging, and permeability properties. The distribution and morphology of clogging materials were investigated to reveal the clogging mechanism in geotextiles used for BEP emergency rescue. This research aims to provide a scientific basis for the selection of geotextiles in the emergency rescue of BEP in dikes.

  5. User

    The following is the first draft of an academic paper of mine. Please help me polish the language. <2 Materials and methodology 2.1 Apparatus The experiment was conducted in an improved GR apparatus, as shown in Figure 1. The apparatus is divided into three parts: upper, middle, and lower, which are connected by flanges and bolts, and the flanges are sealed with rubber pads. The apparatus can accommodate soil samples with a height of 100 mm and a diameter of 100 mm, and the soil sample in the apparatus is used to simulate the foundation soil at the location of BEP water outlet. The flow direction of the water is vertically upward, and the opening in the upper part of the apparatus are used to simulate the BEP outlet. To protect the sand sample from being eroded by the inflow water, a perforated plate and a layer of nylon mesh (with a pore size of 0.12 mm) are placed at the bottom of the sand sample. The geotextile is placed on the top of the sand sample to simulate the process of filtration of geotextile preventing BEP in engineering sites, and the edges of the geotextile are fixed with flange plates. There are five pressure measurement ports distributed on the side of the apparatus to measure the water head at different positions of the sample. The distance between the center of port #5 and the geotextile is 3 mm, and this port is more sensitive to the changes at the soil-geotextile filter interface6,14. The port #5 can capture the interaction between the protective soil and the geotextile filter. The water inlet is connected to the overflow system, which can provide a constant water head for the test. The average hydraulic gradient of the system can be adjusted by changing the water head of the water inlet. Figure 1. Experimental apparatus (unit: mm)

    2.2 Materials Punched nonwoven geotextiles with short fiber and woven geotextiles were selected in this study(Figure 2), which are commonly used in engineering. The detailed parameters are shown in Table 1, and the equivalent opening size (O95) of the geotextile was measured by the bubble point method. The material of nonwoven geotextiles is polyester synthetic fiber. The unit area masses of the three specifications of nonwoven geotextiles are 200 g/m2, 300 g/m2, and 400 g/m2, respectively, and the corresponding O95 are 0.106 mm, 0.051 mm, and 0.047 mm, respectively. The woven geotextile is a flat wire woven geotextile, with material of polypropylene fiber and unit area mass of 200 g/m2, and the O95 is 0.078 mm.

    Figure 2. Geotextiles (a) non-woven geotextile (b)woven geotextile The sand used in the experiment is medium sand, which is a typical sand for foundation of the Yangtze River dike. The specific gravity of the sand is 2.52, and the grading curve is shown in Figure 3. According to the interior stability criterion of Kenney and Lau15, the sand was classified as internally stable. The characteristic particle size of the sand sample is shown in Table 2, with a maximum dry density of 1.82 g/cm3, a minimum dry density of 1.57 g/cm3. In the test, the relative density of the sand was 26.8%, which was in a loose state to simulating the actual situation. The corresponding permeability coefficient at the fill density is 2.33×10-3 cm/s.

    2.3 Experimental design Five sets of experiments were designed to study the influence of geotextile specifications and weaving types on the filtration characteristics of geotextile filters in emergency rescue of dike BEP. Table 3 provides detailed information about the experimental design, and three different specifications of nonwoven geotextiles and one woven geotextile were selected. Test-1 is a control group without geotextile laid at the sand sample. The upstream water head was gradually raised in Test-1 to determine the critical hydraulic gradient of BEP and this hydraulic gradient would be applied in subsequent tests. In Test-2 to Test-5, geotextile filters were placed above the sand sample to study the filtration characteristics of geotextiles. Test-2, Test-3, and Test-4 aim to investigate the influence of nonwoven geotextile specifications on their filtration characteristics, while Test-2 and Test-5 aim to study the influence of geotextile types on their filtration characteristics. The average hydraulic gradient in Test-2 to Test-5 was set to 2.0, and the water head was raised to the design height at one time. In order to improve the reliability of the experimental results, parallel tests were conducted from Test-2 to Test-4.

    2.4 Experimental procedure (1) Specimen preparation First, the ends of the five pressure measurement tube interfaces were blocked with lightweight geotextile (150 g/m2) to prevent sand from entering the pressure measurement tubes during sample installation. The inlets of the five ports were first plugged with light geotextile (150 g/m2) to prevent sand from entering the pressure measurement tube. A perforated plate and a layer of nylon mesh were placed at the bottom of the GR apparatus. Then, the sand sample was filled underwater with a dry density of 1.63 g/cm3 to ensure saturation. The height of the sand sample was 100 mm, and it was filled in four layers with a thickness of 25 mm each. After the filling process, a saturated geotextile (diameter of 120 mm) was placed on top of the sand sample. Afterwards, the upper water outlet module was installed with bolts, and the rubber pad was used to ensure the sealing of each part of the apparatus. During the test, the apparatus was handled gently to avoid disturbing the sample structure. The geotextile was saturated by placing it in a solution containing sodium dodecyl benzene sulfonate with a volume fraction of 0.1% for 12 hours. The experimental process is shown in Figure 4. (2) Experimental process The water inlet valve was closed and the water level of the overflow system was adjusted to the top surface of the sample. Then the inlet valve was opened, and the upstream water level was raised to designed height after the water heads of the five pressure measurement tubes were equal. For Test-1, the upstream water level was raised step by step, with an initial increase of 2 cm each time in the early stage and 1 cm each time in the later stage. Based on the experimental result of Test-1, The average hydraulic gradient was set to 2.0 in Test-2 to Test-5 to ensure the occurrence of BEP, and the water head was raised to the design height at one time. The water heads of the pressure measurement tubes and the system flow rate were recorded regularly, with smaller initial measurement intervals gradually increasing to every 2 hours. When the water head readings of the pressure measurement tubes stabilize, the water outlet was closed and the test was stopped, with each test lasting about 12 hours. After the test, the sand particles passing through the geotextile filter was collected, dried and weighed. The geotextile was taken out for drying, weighing, and clogging analysis.

    (3) Analytical method Geotextile filters in emergency rescue of dike BEP need to meet good filtration properties, including the soil retention, permeability, and anti-clogging properties16. By comparing the GR value, flow rate, and variations of geotextile mass and other parameters in different tests, the filtration characteristics of geotextile filters were analyzed. The GR value is an important index of geotextile clogging. The definition of GR25 is as follows:

    In the formula, i0-25 is the hydraulic gradient from the geotextile filter to the 25 mm thick soil sample below it, and i25-75 is the hydraulic gradient of the 25-75 mm soil sample below the filter layer of the geotextile. A GR25 value less than or equal to 1 and remaining stable over time indicates good filtration characteristics of the geotextile filter. A GR25 value less than 1 and continuous decrease over time suggests the presence of piping channels in the geotextile filter, with fine-grained soil passing through the geotextile. A GR25 value greater than 1 indicates that the geotextile or its surface is clogged by soil particles, leading to a reduction in drainage capacity of geotextile filter. According to the US Army Corps of Engineers, a GR25 value greater than 3 suggests that the clogging of geotextile filter is at an unacceptable level.>

  6. Assistant
    1. Materials and Methodology

    2.1 Experimental Apparatus The experiment was conducted using an improved GR apparatus, as depicted in Figure 1. The apparatus consists of three parts: the upper, middle, and lower sections, which are connected by flanges and bolts. Rubber pads are used to seal the flanges. The apparatus is designed to accommodate soil samples measuring 100 mm in height and 100 mm in diameter, simulating the foundation soil at the location of the BEP water outlet. The water flow direction is vertically upward, and the upper part of the apparatus is used to simulate the BEP outlet. To protect the sand sample from erosion by inflow water, a perforated plate and a layer of nylon mesh with a pore size of 0.12 mm are placed at the bottom of the sand sample. The geotextile is placed on top of the sand sample to simulate the filtration process employed in preventing BEP in engineering sites

Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.