A given rocket engine has a combustion chamber pressure of 1.5 MPa and an expansion…
- User
A given rocket engine has a combustion chamber pressure of 1.5 MPa and an expansion ratio of 60. When ignited at atmospheric pressure (1.01× 105 Pa) the flow is overexpanded and a shock is required for the flow to adjust to the external pressure. You can assume that the ratio of specific heats is approximately 1.4. Determine whether the shock appears inside or outside the nozzle.
- Assistant
To determine whether the shock appears inside or outside the nozzle, we need to compare the nozzle exit pressure to the external pressure.
Given: Combustion chamber pressure, P1 = 1.5 MPa = 1.5 × 10^6 Pa Expansion ratio, ER = 60 Atmospheric pressure, P0 = 1.01 × 10^5 Pa Ratio of specific heats, γ = 1.4
We can calculate the nozzle exit pressure using the ratio of specific heats (γ) and the expansion ratio (ER):
P2 = P1 / (1 + (γ - 1)/2 * ER^2)^(γ / (γ - 1)) P2 = 1.5 × 10^6 / (1 + (1.4 - 1)/2 * 60^2)^(1.4 / (1.4 - 1))
Using this equation, we find P2 ≈ 102.34 Pa.
Now, we compare the nozzle exit pressure (P2) to the external pressure (P0): If P2 < P0, then the shock appears inside the nozzle. If P2 > P0, then the shock appears outside the nozzle.
In this case, P2 ≈ 102.34 Pa and P0 = 1.01 × 10^5 Pa. Since P2 < P0, the shock appears inside the nozzle.
- User
A given rocket engine has a combustion chamber pressure of 1.5 MPa and an expansion ratio of 60. When ignited at atmospheric pressure (1.01× 105 Pa) the flow is overexpanded and a shock is required for the flow to adjust to the external pressure. You can assume that the ratio of specific heats is approximately 1.4. Determine whether the shock appears inside or outside the nozzle. If the shock is internal, determine the location of the shock in the nozzle. Because we don’t know the details of the nozzle geometry, we can’t give this as a distance along the axis of the nozzle, but it can be expressed as the ratio of the nozzle cross-sectional area where the shock is to the throat area or to the exit area–calculate both. If a weaker external oblique shock is required instead of an internal normal shock, calculate the angle of the oblique shock with respect to the nozzle axis (assuming the flow upstream is parallel to the axis.)
- Assistant
To determine the location of the shock in the nozzle, we need to compare the nozzle exit pressure to the external pressure. If the shock is internal, we can calculate the location of the shock expressed as the ratio of the nozzle cross-sectional area where the shock is to the throat area or to the exit area.
Given: Combustion chamber pressure, P1 = 1.5 MPa = 1.5 × 10^6 Pa Expansion ratio, ER = 60 Atmospheric pressure, P0 = 1.01 × 10^5 Pa Ratio of specific heats, γ = 1.4