翻译为中文:
Abstract
Purpose In continuous manufacturing of pharmaceuticals, dry granulation is of interest because of its large throughput capacity
and energy efficiency. In order to manufacture solid oral dosage forms continuously, valid control strategies for critical quality
attributes should be established. To this date, there are no published control strategies for granule size distribution in continuous
dry granulation.
Methods In-line laser diffraction was used to determine the size of granules in a continuous roll compaction/dry granulation line
(QbCon® dry). Different process parameters were evaluated regarding their influences on granule size. The identified critical
process parameters were then incorporated into control strategies. The uncontrolled and the controlled processes were compared
based on the resulting granule size. In both processes, a process parameter was changed to induce a shift in median particle size
and the controller had to counteract this shift.
Results In principle, all process parameters that affect the median particle size could also be used to control the particle size in a
dry granulation process. The sieve impeller speed was found to be well suited to control the median particle size as it reacts fast
and can be controlled independently of the throughput or material.
Conclusion The median particle size in continuous roll compaction can be controlled by adjusting process parameters depending
on real-time granule size measurements. The method has to be validated and explored further to identify critical requirements to
the material and environmental conditions.
Keywords Continuous manufacturing . Roll compaction/dry granulation . Process analytical technologies . Laser diffraction .
Process control . Feedback control
Introduction
Continuous manufacturing (CM) in the production of pharmaceutical
solid oral dosage forms is characterized by the connection
of individual processes into one line, ideally from raw
excipients and active pharmaceutical ingredient (API) to final dosage form. Potentials of this production concept include
higher flexibility of production volume and time as well as
increased quality due to tight monitoring and control strategies
[1–4]. Regulatory agencies and the International Council of
Harmonization (ICH) have shown support of this approach
[5–11]. A new guideline, ICH Q13, is currently developed
for continuous manufacturing processes [12]. However, monitoring
and control strategies have to be developed by the
manufacturers prior to taking advantage of this manufacturing
technique. High priority is set to process-analytical technologies
(PAT) which aim at executing timely (in-line or on-line)
measurements and determining critical quality attributes
(CQA) [13]. As described by the U.S. FDA, in-line measurements
are characterized by the sample not being removed
from the process [6]. Using this concept, time and resources
can be drastically reduced. As a necessary premise, traditional characterization techniques (e.g. particle size or API concentration
determination) have to be transferred to robust realtime
measurements [14].
While direct compression is the favorable process in continuous
manufacturing, it is not always possible due to the raw
materials properties (especially poor flow properties or segregation
issues of powder material). Therefore, a granulation
step might be needed prior to tableting. The manufacturing
classification system (MCS) is a joint effort from academic
and industrial technology experts to rank the feasibility of
pharmaceutical processing routes for solid dosage forms. It
ranks roll compaction/dry granulation (RCDG) as the granulation
method of choice, if direct compression is not possible
[15]. It is favorable due to its natural continuity, large throughput
possibilities and energy efficiency [16]. It is however not
suitable for all formulations as the capability of improving the
flow properties is limited based on the large amount of fines in
the final granules and the undesired effect of reduced
tabletability that is well described in literature [17–19]. A
CQA in granulation is the granule size distribution (GSD) of
the granulatedmaterial [20, 21].While there are multiple measurement
principles and apparatuses, most of them are set up
in a discontinuous way and do not allow continuous GSDdetermination.
However, due to the growing interest there
have been reports of continuous size determination in the production
of pharmaceuticals [22–27]. Size determination has
proven to be challenging in continuous RCDG due to the high
throughput, the bimodal size distribution with a large fraction
of fines and the inhomogeneous product stream [28–32]. The
use of laser diffraction, as a non-invasive, in- and on-line
technique to monitor the GSD during continuous RCDG
was recently published [33].
However, monitoring is only the first step to a process
control strategy. To develop a control strategy, a CQA has
to be adequately measured first. Afterwards, it is necessary
to determine a specification window for the CQA and to find
a process parameter that can be controlled which affects the
CQA in a desired way. It is well known that the specific
compaction force (SCF) and gap width affect the GSD of
dry granulated material [34]. However, especially the SCF is
a key critical process parameter (CPP) that affects further
properties (e.g. hardness [35], porosity [36, 37] and throughput
[38] if only the SCF is changed).
Singh et al. (2012) [39] mentioned that the particle size in
continuous RCDG could be controlled by adjusting the milling
speed of the granulation unit. This claim was statistically
analyzed by Mangal et al. in 2018 [40]. The group confirmed
that the impeller speed of a conical sieve in the milling unit of
a roll compactor has significant impact on the median particle
size and the amount of fines. This was evaluated for three
different raw materials and two formulations containing ibuprofen
and acetaminophen as active pharmaceutical ingredient
(API). Mangal claimed that high impeller speeds should be avoided as it could lead to large amount of fines and slow
speeds could bear issues in milling the material in adequate
time. However, these claims were not backed with data and
should be evaluated further.
For a CPP that influences the granule size, it should be
possible to program a controller to react to changes in the
desired CQA by adjusting the chosen process parameter.
Examples of PAT-controllers in pharmaceutical manufacturing,
e.g. in fluidized bed processes, can be found in literature
[41, 42].
The aim of this study was to advance the previously published
monitoring strategy for GSD in continuous dry granulation
to a control strategy [33]. The proof of principle was
supposed to be given for various parameters to be controlled.
Therefore, process parameters in RCDG were evaluated for
their suitability as control valves. Controller parameters and
data analysis were optimized to evaluate the applicability in
industrial manufacturing. Implementing a control strategy for
granule size in continuous granulation is the next step in the
continuous process of implementing advanced manufacturing
techniques in the pharmaceutical industry.