Below is a paragraph from an academic paper. Polish the writing to meet the academic…
- User
Below is a paragraph from an academic paper. Polish the writing to meet the academic style, improve the spelling, grammar, clarity, concision and overall readability. When necessary, rewrite the whole sentence. Furthermore, list all modification and explain the reasons to do so in markdown table. Paragraph: In the present experiments, the measurement error of thermocouple and pressure sensor is ±50 Pa and ±6 K, respectively. The error of pressure sensor could cause an un-certainty of less than 2.5% for the oscillation amplitude under SETAI condition. The error of thermocouple could introduce an uncertainty of 1 m/s for the sound speed, and then the resulted error for f is less than 0.5%. In addition, the measurement error of flowmeter is ±0.0174 L/min in propone flow rate and ±0.1006 L/min for air flow rate. These errors could cause a maximum error of 2.8% for φ.
- Assistant
In the present experiments, the measurement error of the thermocouple and pressure sensor is ±50 Pa and ±6 K, respectively. The error of the pressure sensor could result in an uncertainty of less than 2.5% for the oscillation amplitude under SETAI conditions. Moreover, the error of the thermocouple could introduce an uncertainty of 1 m/s for the sound speed. Consequently, the resulting error for f is less than 0.5%. Additionally, the measurement error of the flowmeter is ±0.0174 L/min for propane flow rate and ±0.1006 L/min for air flow rate. These errors could contribute to a maximum error of 2.8% for φ.
Modification Reason Rephrased sentence structure for better clarity - User
Below is a paragraph from an academic paper. Polish the writing to meet the academic style, improve the spelling, grammar, clarity, concision and overall readability. When necessary, rewrite the whole sentence. Furthermore, list all modification and explain the reasons to do so in markdown table. Paragraph: Figure 2 shows the comparison of sound pressure oscillation between an asym-metric supply structure (case 35) and two symmetric systems (case 8 and 9). In case 35, L1 and L2 is respectively the same as the premixed chamber length in case 8 and 9. These two symmetric structure both show strong oscillation, with the frequency being 70.4 and 72.6 Hz, respectively. For case 35, the sound pressure is also a strong oscilla-tion, that its frequency spectrum has only one peak at 72.4 Hz, rather than presenting two oscillations respectively at 70.4 and 72.6 Hz. Figure 3 shows the oscillation condition of another asymmetric condition (case 32) with comparison to its correlative symmetric systems (case 9 and 5). The frequency spectrum of case 32 shows a bimodal feature, being close to case 5. Another important observation is that the amplitude is lower for the asymmetric system in comparison to those two symmetric systems. Both Figures 2 and 3 supported that the sound pressure oscillation behavior of an asymmetric system is not the linear superposition of the two correlative symmetric systems, but the frequency is different from either.
- Assistant
- User
Below is a paragraph from an academic paper. Polish the writing to meet the academic style, improve the spelling, grammar, clarity, concision and overall readability. When necessary, rewrite the whole sentence. Furthermore, list all modification and explain the reasons to do so in markdown table. Paragraph: The oscillation dependence on one-side premixed chamber length was examined with the other side’s length being fixed (case 28–62 in Table 1b). The sound pressure amplitude and frequency variation with L2 was compared with the correlative sym-metric system (changing L1 equally with L2), as the results shown in Figures 4–6. When L1 is fixed at 2.06 m, with increasing L2 from 0.55 to 2.06 m, the combustion successively experiences non-, intermittent-, and continuous oscillation, and then returns to non-oscillation at 2.26–2.46 m to start another cycle. The oscillation dependence on L2 is similar to that on LP under the symmetric supply system [25]. For all the continu-ous-oscillation condition, PRMS under asymmetric supply system is always lower than the correlative symmetric systems. The experiments conducted under φ = 0.7 and L1 = 2.66 m also show the same trend, as shown in Figure 5. The most intense oscillation for asymmetric supply system with L1 being fixed at 2.06 and 1.65 m is case 35 and 45, re-spectively. Both are under L2 = 1.85 m, and the PRMS is respectively 30% and 42% lower than the symmetric supply system (L1 = L2 = 2.06 m). Figure 6 present several minor difference in comparison to Figures 4 and 5. For case 45 (L1 = 1.65 m, L2 = 1.85 m) and case 63 (L1 = 1.65 m, L2 = 1.45 m), the oscillation intensity is between the two correlative symmetric systems. An intermittent oscillation occurs under case 60 (L1 = 1.65 m, L2 = 0.85 m), but both correlative symmetric systems show sustained oscillation. The combination of 1.65 m (sustained oscillation in sym-metric systems) and 2.26 m (non-oscillation in symmetric systems) results in a sus-tained oscillation. These seemingly irregular relationships indicate the oscillation characteristic under asymmetric supply structures is not straightforward.
- Assistant
- User
- Assistant
Figure 7 illustrates the comparison of sound pressure oscillation and its frequency spectrum between two cases (case 66 and 67) with asymmetric supply structure and asymmetric combustion conditions. While the supply system structure, total VF, and global φ remain the same in both cases, case 67 exhibits strong oscillation, whereas case 66 only displays combustion noise. The PRMS under case 66 is approximately 1/10 of that under case 67. Previous investigations have shown that LP and φ collectively influence the interaction between sound pressure oscillation and heat release oscillation, determining whether SETAI can be encouraged [9,25].
Specifically, when LP/λP complies with Equation (5), the mode shape within the premixed chamber corresponds to a quarter to a half wave. In this scenario, a pressure node will exist upstream of the flame stabilizer, as the far end (inlet) of the premixed chamber acts as a pressure antinode due to its near-closed acoustic boundary condition. It should be noted that there is a potential error regarding the far end of the premixed duct not completely adhering to a closed boundary condition. Thus, when the instantaneous pressure at the flame stabilizer exceeds its average value, the pressure will increase in the flow direction. This pressure difference between the two sides of the flame stabilizer will reduce the mixture flow rate, causing a flow rate oscillation that lags the pressure oscillation by 90° if Equation (6) is satisfied