请将以下内容翻译为英文:频率对pH的影响如图2d所示,橙汁原pH值为3.88,在不同频率处理后,橙汁的pH值并没有明显变化,可忽略不计。
- User
请将以下内容翻译为英文:频率对pH的影响如图2d所示,橙汁原pH值为3.88,在不同频率处理后,橙汁的pH值并没有明显变化,可忽略不计。
- Assistant
The effect of frequency on pH is shown in Figure 2d. The orange juice initially had a pH value of 3.88. After being treated at different frequencies, the pH value of the orange juice did not show any significant changes and can be ignored.
- User
请将以下内容翻译为英文:处理时间对灭菌率及各项指标的影响如图3所示。
- Assistant
The effect of treatment time on sterilization rate and various indicators is shown in Figure 3.
- User
请将以下内容翻译为英文:在图3a中,处理5 min即可达到58.2 %的灭菌率,随着处理时间延长,灭菌率也不断升高,处理15 min灭菌率达到83.0 %,随后趋于稳定,最高在处理25 min后达到86.9 %。处理时间对灭菌率影响的实验结果表明,活性物质不断进入橙汁消耗自身去破坏细胞结构,时间积累越久,活性物质量越大,灭菌数越多,灭菌率才会越高。本实验中,灭菌15 min后,灭菌率随时间增加变缓,说明即使继续延长时间,灭菌率也不会达到100.0 %,其原因可能与电压对灭菌率的影响相同,等离子体在固定电压下对橙汁液体的穿透厚度有限,所以无法达到完全灭菌。
- Assistant
In Figure 3a, it can be seen that a sterilization rate of 58.2% can be achieved with a treatment time of 5 minutes. As the treatment time increases, the sterilization rate continues to rise. With a treatment time of 15 minutes, the sterilization rate reaches 83.0% and then stabilizes. The highest sterilization rate of 86.9% is achieved after a treatment time of 25 minutes. The experimental results regarding the impact of treatment time on sterilization rate indicate that the active substances continuously enter the orange juice, consuming themselves to destroy the cell structure. The longer the time accumulation, the greater the amount of active substances and the higher the sterilization rate. In this experiment, after 15 minutes of sterilization, the sterilization rate increases at a slower rate with the extension of time. This suggests that even with further prolongation of time, the sterilization rate will not reach 100.0%. One possible reason for this is that the effect of voltage on the sterilization rate is the same. The plasma has a limited penetration thickness into the orange juice liquid under a fixed voltage, hence it cannot achieve complete sterilization.
- User
请将以下内容翻译为英文:处理时间对灭菌率及各项指标的影响
- Assistant
The effect of treatment time on sterilization rate and various indicators
- User
请将以下内容翻译为英文:处理时间对色差的影响如图3b所示。色差在处理5 min时达到最大值14.73,并随着处理时间的延长不断减小,在处理25 min时达到最小值9.05,此时灭菌橙汁颜色与原汁差别不大,肉眼可以辨别但作为橙汁饮料可以接受。
- Assistant
The effect of treatment time on color difference is shown in Figure 3b. The color difference reaches its maximum value of 14.73 at a treatment time of 5 minutes and gradually decreases as the treatment time is extended. At a treatment time of 25 minutes, the color difference reaches its minimum value of 9.05. At this point, the color difference between sterilized orange juice and the original juice is not significant, and it can be visually distinguishable but acceptable as an orange juice beverage.
- User
请将以下内容翻译为英文:处理时间对总酚含量的影响如图3c所示,总酚含量随着处理时间的延长而迅速降低,处理20 min时降至最低8.54 mg/mL,根据前文关于总酚内容的论述,这样的变化是合理的。处理25 min时,总酚含量突然增高至9.32 mg/mL,考虑到长时间的灭菌会导致橙汁温度升高,橙汁中热敏性化合物水解产生单体或二聚体酚类而导致其在处理25 min后突然升高,这样的变化也是合理的。
- Assistant
The effect of treatment time on total phenolic content is shown in Figure 3c. The total phenolic content rapidly decreases with the extension of treatment time. It reaches its lowest value of 8.54 mg/mL at a treatment time of 20 minutes. This change is reasonable based on earlier discussions about total phenolic content. However, at a treatment time of 25 minutes, the total phenolic content suddenly increases to 9.32 mg/mL. Considering that prolonged sterilization can lead to an increase in the temperature of the orange juice, it is reasonable to assume that heat-sensitive compounds in the juice hydrolyze to form monomeric or dimeric phenolic compounds, leading to the sudden increase in total phenolic content after 25 minutes of treatment.
- User
请将以下内容翻译为英文:根据单因素实验结果,用响应面法对电晕放电等离子体处理橙汁工艺进行优化,以灭菌率作为响应值,进行三因素三水平Box-Behnken响应面优化实验,17个实验组结果如表2所示。
- Assistant
Based on the results of single-factor experiments, the response surface methodology was used to optimize the process of orange juice treatment with corona discharge plasma. The sterilization rate was chosen as the response variable, and a three-factor three-level Box-Behnken response surface optimization experiment was conducted. The results of the 17 experimental groups are shown in Table 2.
- User
请将以下内容翻译为英文:将上述结果用Design Expert 12软件进行分析,使用Quadratic模型进行初步拟合,在剔除不显著项和添加高次项后其模型结果如下式所示:
- Assistant
The above results were analyzed using Design Expert 12 software. A preliminary fitting was performed using a Quadratic model. After eliminating insignificant terms and adding higher-order terms, the model can be expressed as follows:
- User
请将以下内容翻译为英文:式中:Y——灭菌率/%;A——电压/kV;B——频率/kHz;C——时间/min; 响应面方差分析如表3所示。
- Assistant
In the equation: Y - sterilization rate/%; A - voltage/kV; B - frequency/kHz; C - time/min.
The variance analysis of the response surface is shown in Table 3.
- User
请将以下内容翻译为英文:由表3可知,该模型F值为11.34,且由噪声干扰出现这种结果的可能性仅为0.75 %,说明该模型为极显著模型。P值小于0.0500表示模型项显著,P值小于0.0100表示模型项极显著, B,C²是极显著模型项,BC,A²,AB²是显著模型项。其余模型项不显著(P>0.05)。失拟项F值为2.96,相对于纯误差并不显著,同时失拟项P值为0.1606,表示在噪声干扰下,有16.06 %概率会产生F值为2.96的失拟情况,表明该模型失拟不显著。该模型R2为0.9615,表明96.15 %的实验结果都能用该模型预测,同时其测量信噪比为9.372,说明噪声占比很小,可用信息充足,且其比值大于4,说明该模型可以用于设计实验结果的预测。
- Assistant
From Table 3, it can be observed that the F-value of the model is 11.34, and the probability of obtaining this result due to noise interference is only 0.75%, indicating that the model is highly significant. A p-value less than 0.0500 indicates a significant model term, while a p-value less than 0.0100 indicates a highly significant model term. In this case, B, C² are highly significant model terms, and BC, A², AB² are significant model terms. Other model terms are not significant (p > 0.05).
The lack of fit F-value is 2.96, which is not significant compared to the pure error. The p-value for lack of fit is 0.1606, indicating that there is a 16.06% probability of occurrence of lack of fit with an F-value of 2.96 under noise interference. This suggests that the lack of fit in the model is not significant. The model has an R-squared value of 0.9615, indicating that 96.15% of the experimental results can be predicted by the model. Furthermore, the signal-to-noise ratio of the model is 9.372, indicating that the noise contribution is minimal and there is sufficient information. Additionally, the ratio is greater than 4, indicating that the model can be used to predict experimental results.
- User
请将以下内容翻译为英文:在电压为40 kV的条件下,时间与频率的交互作用对灭菌率影响的等高线和响应面如图4所示。图4中的等高线图左侧为高灭菌率区域,右侧为低灭菌率区域,灭菌率随着时间的延长和频率的降低而升高,根据图中等高线分布以及响应面的形态,可以看出频率对灭菌率的影响更为显著。
- Assistant
The contour plot and response surface showing the interaction effects of time and frequency on sterilization rate under the condition of 40 kV voltage are depicted in Figure 4. In the contour plot, the high sterilization rate region is on the left side, while the low sterilization rate region is on the right side. The sterilization rate increases with the extension of time and the decrease of frequency. Based on the contour distribution in the figure and the shape of the response surface, it can be observed that the frequency has a more significant impact on the sterilization rate.