Sample extraction: Extract proteins from the target cells or tissues using a suitable lysis buffer that preserves the proteins' integrity.
-
Protein quantification: Measure the protein concentration by using methods such as the Bradford or BCA assay.
-
SDS-PAGE: Perform SDS-PAGE (sodium dodecyl sulfate-polyacrylamide gel electrophoresis) to separate the proteins based on their size. Prepare a gel with different concentrations of polyacrylamide depending on the protein size range of interest.
a. Prepare stacking and separating gels.
b. Load protein samples along with a molecular weight marker.
c. Run the gel at a constant voltage until the marker bands reach the bottom.
-
Protein transfer: Transfer the separated proteins from the gel onto a nitrocellulose or PVDF (polyvinylidene fluoride) membrane using the western transfer technique, typically by electroblotting.
a. Soak the membrane in transfer buffer.
b. Assemble the transfer sandwich: membrane, gel, filter paper, and a sponge.
c. Place the sandwich into the blotting apparatus.
d. Run the transfer at a constant voltage for a specific period.
-
Blocking: Block the membrane to prevent non-specific binding by incubating it with a blocking solution (usually 5% non-fat milk or BSA) for approximately 1 hour at room temperature or overnight at 4°C.
-
Primary antibody incubation: Dilute the primary antibody (specific to the target protein) in a suitable antibody diluent and incubate the membrane with it for 1-2 hours at room temperature or overnight at 4°C while gently shaking.
-
Washing: Wash the membrane multiple times with a suitable washing buffer (usually TBS or PBS) to remove any unbound primary antibody.
-
Secondary antibody incubation: Dilute a secondary antibody specific to the primary antibody's host species (e.g., if the primary antibody is raised in rabbit, use an anti-rabbit secondary antibody) and incubate the membrane with it for 1 hour at room temperature while gently shaking.
-
Washing: Wash the membrane multiple times to remove any unbound secondary antibody.
-
Protein detection: Use a suitable detection system, such as chemiluminescence or fluorescence, to visualize the protein bands.
a. Apply the detection reagent(s) to the membrane as per the manufacturer's instructions.
b. Incubate the membrane for a specific duration, allowing the detection reaction to occur.
c. Capture the chemiluminescent or fluorescent signals using a specialized imaging system.
Note: It is crucial to carefully design controls, including positive and negative controls, to validate and interpret the results accurately.