can you correct spelling and grammar and make this as professional as possible also make…
- User
can you correct spelling and grammar and make this as professional as possible also make it neutral encase it were to be used in a law suit. "At 5:20 PM we got a page from the ER in regards to a squeliching noise coming from the trauma room and the resuscitation room. Dave and I stopped painting SPD's break room and went right over and discovered the two SpaceLabs machines inside trauma A & B were making an audible alarm. The same machine was in alarm inside the resuscitation room. All outlets were labeled as the A circuits so Dave and I began looking for a breaker and shortly after saw the digital readout on panel A was dead but B had a readout. We saw no breakers were tripped and made a call to Ben. Shortly after we all began trying to trace down the main panel that fed panel A to the truama. We were not able to get ahold of the right people from Driscoll for a little while but when we did they directed us to floor 1 across from OR 5. We were able to locate the labeled supply for panel A in the trauma room. It was on and there were no tripped breakers. During the process we were working with the trauma team and with the feed being on Driscoll thought it may have been a blown transformer in panel A so we moved all equipment over to panel B circuits. At this point we had all of the trauma staff involved to discuss diverting patients if needed. They made sure all their equipment would work and be able to handle any trauma that would come in the way the room was set up. Ben continued to escalate this issue with Driscoll and wanted some one to come to the premise on 6/6. From this point forward I was not directly involved and went back to SPD to try to save the brush and roller we had left as it had been sitting for a long time. Driscoll sent Scott Ritter to fix the issue we were having and shortly after arrival he went to work that had been performed earlier in the day. Ben said they had turned off a circuit that had the same labeling as the panel in the trauma room (A). They had removed the label from the original breaker, put a lockout tagout on the breaker and switched the label to a different breaker because they thought the correct breaker was the one they moved the label to."
- Assistant
At approximately 5:20 PM, a notification was received from the ER regarding a squelching noise emanating from the trauma and resuscitation rooms. Upon receiving the page, Dave and I immediately halted painting activities in SPD's break room and conducted an investigation. We detected an audible alarm from the two SpaceLabs machines located in Trauma A & B, which was also present in the resuscitation room. After discovering that all the outlets were labeled as circuit A, we began searching for a breaker. A digital readout on panel A was found to be non-functional, while panel B had a readout. Despite our efforts, we could not locate any tripped breakers. Consequently, we contacted Ben and together, we endeavored to trace the main panel that served panel A in the trauma room. However, we faced a little challenge locating the right people from Driscoll.