Seven frequency measurements were made: f = 41.02; 41.03; 41.04; 41.03; 41.01; 41.02;…
- User
Seven frequency measurements were made: f = 41.02; 41.03; 41.04; 41.03; 41.01; 41.02; 41.05 kHz. The measurement error is distributed according to the Gaussian law. Determine the point and interval estimates of the frequency measurement (with 0.95 confidence interval probability)
- Assistant
To determine the point and interval estimates of the frequency measurement, we first need to calculate the mean (average) and standard deviation of the data set.
Mean (average) = (sum of all measurements) / (number of measurements) Mean = (41.02 + 41.03 + 41.04 + 41.03 + 41.01 + 41.02 + 41.05) / 7 = 287.2 / 7 = 41.02857 kHz (rounded to 5 decimal places)
Next, calculate the standard deviation: Standard deviation = sqrt(sum[(each measurement - mean)^2] / (number of measurements - 1))
To make it easier, let's first calculate the sum of squares: Sum of squares = (41.02 - 41.02857)^2 + (41.03 - 41.02857)^2 + ... + (41.05 - 41.02857)^2 Sum of squares = 0.000073 + 0.000002 + 0.000132 + 0.000002 + 0.000317 + 0.000073 + 0.000477 = 0.001076
Now we can find the standard deviation: Standard deviation = sqrt(0.001076 / 6) = sqrt(0.000179) = 0.0134 kHz (rounded to 4 decimal places)
Now we need to determine the confidence interval. Since it's given that the measurement error is distributed according to the Gaussian law, we can use the t-distribution table to find the t-value for the 95% confidence interval with (7 - 1 = 6) degrees of freedom. From the t-table, the corresponding t-value is 2.447.
Standard Error = Standard Deviation / sqrt(number of measurements) = 0.0134 / sqrt(7) = 0.0051 (rounded to 4 decimal places)
Now, we can calculate the 95% confidence interval:
- Lower limit: Mean - t-value * Standard Error = 41.02857 - 2.447 * 0.0051 = 40.9979 kHz (rounded to 4 decimal places)
- Upper limit: Mean + t-value * Standard Error = 41.02857 + 2.447 * 0.0051 = 41.0592 kHz (rounded to 4 decimal places)
Thus, the point estimate of the frequency measurement is 41.02857 kHz, and the 95% confidence interval estimate is (40.9979 kHz, 41.0592 kHz).