For a certain thermistor β = 3420 K, and the resistance at 366.33 K is known to be 1010…
- User
For a certain thermistor β = 3420 K, and the resistance at 366.33 K is known to be 1010 ± 3 Ω. The thermistor is used for temperature measurement, and the resistance is measured as 2315 ± 4 Ω. Calculate the temperature and the uncertainty.
- Assistant
We can use the Steinhart-Hart equation to relate the temperature and resistance of a thermistor:
1/T = a + b * ln(R) + c * ln(R)^3
where T is the absolute temperature, R is the resistance in ohms, and a, b, and c are constants specific to the thermistor.
We can solve for the temperature and its uncertainty using error propagation. The uncertainty in the temperature can be calculated as:
δT = √((δa)^2 + (δb * ln(R))^2 + (δc * ln(R)^3)^2)
where δa, δb, and δc are the uncertainties in the constants and δR is the uncertainty in the resistance.
First, we need to calculate the constants a, b, and c using the data we have: