An effective protection against switch cross conduction is implemented by introducing…
- User
An effective protection against switch cross conduction is implemented by introducing commutation dead-times, i.e., suitable delays before the switch turn on signal is applied to the gate. e effect of dead-times is shown in Fig. 2.2, in the hypothesis that a positive current IO is flowing through the load. e figure assumes that a period of observation can be defined, whose duration is TS , where switches S1 and S2 are meant to be on for times tON1 and tON2, respectively, and where the load current is assumed to be constant (i.e., the load time constant LS =RS is as- sumed to be much longer than the observation period TS ). e existence of such an observation period guarantees that the definition of average load voltage is well posed. By that we simply mean the weighted average over time of the instantaneous load voltage in the period of observation. To avoid cross conduction, the modulator delays S1 turn-on by a time tdead , applying the VGE1 and VGE 2 command signals to the switches. e duration of tdead is long enough to allow the safe turn-off of switch S2 before switch S1 is commanded to turn on, considering propagation delays through the driving circuitry, inherent switch turn off delays and suitable safety margins. e required dead-time duration is a direct function of the switch power rating and, for a typical 600 V, 40 A IGBT, is well below 1 μs. Considering Fig. 2.2, it is important to notice that the effect of the dead-time application is the creation of a time interval where both switches are in the off state and the load current flows through the free-wheeling diodes. Because of that, a difference is produced between the desired duration of the S1 switch on time and the actual one, that turns into an error in the voltage across the load. It is as well important to notice that the opposite commutation, i.e., where S1 is turned off and S2 is turned on, does not determine any such voltage error. However, we must point out that, if the load current polarity were reversed, the dead-time induced load voltage error would take place exactly during this commutation. 翻译
- Assistant
引入换流死区时间是一种有效的保护措施,可以有效防止开关交交叉导通。换流死区时间即是在开关启动信号施加到门极之前,适当的延迟时间。在负载中存在一个持续时间为TS的观察周期,假设正电流IO通过负载。图2.2展示了换流死区时间的影响。图中假设存在一个持续时间为TS的观察周期,在该周期内,开关S1和S2的开启时间分别为tON1和tON2,且假定负载电流是恒定的(即假设负载时间常数LS=RS远大于观察周期TS)。这样就确保了平均负载电压的定义是合理的。这里所述的平均负载电压是指一个加权时间平均值,在观察周期内负载瞬时电压的平均值。
为了避免交交叉导通,调制器通过延迟tdead来控制S1的开启时间,并向开关施加VGE1和VGE2命令信号。tdead的持续时间足够长,可以确保在S1被命令开启之前,通过驱动电路的传播延迟、器件本身的开关关断延迟和适当的安全裕度来安全地关闭开关S2。
所需的死区时间与开关功率评级直接相关,对于典型的600V 40A IGBT,死区时间远低于1μs。
从图2.2可得出,死区时间的应用产生了一个时间间隔,在该时间间隔内,两个开关都处于关闭状态,负载电流通过自由调节二极管。因此,在S1开关的理想开启时间和实际开启时间之间会产生误差,这会导致负载电压的误差。另外需要注意的是,相反的换流,即关闭S1并打开S2时,不会产生任何这样的电压误差。然而,我们必须指出,如果负载电流的极性反转,则死区时间引起的负载电压误差将恰好在此换流过程中发生。
- User
e above discussion reveals that, because of dead-times, no matter what the modulator implementation is, an error on the load voltage will always be generated. is error VOC, whose entity is a direct function of dead-time duration and whose polarity depends on the load current sign according to the following relation 翻译
- Assistant
上述讨论揭示了,由于死区时间的存在,无论调制器如何实现,都将产生负载电压误差。这个误差VOC的大小与死区时间的持续时间成正比,其极性依赖于负载电流符号,可以根据以下关系得出:
- User
will have to be compensated by the current controller. Failure to do so will unavoidably determine a tracking error on the trajectory the load current has to follow (i.e., current waveform distortion). We will later see how some current controllers are inherently immune to dead-time induced dis- tortion, while others are not. We cannot end this discussion of dead-times without adding that, motivated by the con- siderations above, several studies have been presented that deal with their compensation. Both off line, or feed-forward, techniques and closed-loop arrangements have been proposed to mitigate the problem. e interested reader can find very detailed discussions of these topics in technical papers like, for instance, [2] and [3].
- Assistant
缺乏对电流控制器进行补偿将不可避免地导致负载电流跟踪轨迹的跟踪误差(即电流波形失真)。稍后我们将看到一些电流控制器天生具有免疫死区时间引起的失真,而另一些则没有。
在没有补偿的情况下,死区时间会对负载电压造成误差。因此,出于上述考虑,人们提出了许多关于如何补偿死区时间的研究。既有离线的前馈技术,也有闭环方案。有关这些主题的非常详细的讨论,读者可参考像[2]和[3]这样的技术论文。
- User
e definition of a suitable modulation law represents the first step in any converter control de- sign. Several modulation techniques have been developed for switch mode power supplies: for the VSI case, the most successful is, undoubtedly, the pulse width modulation (PWM). Compared to other approaches, like pulse density modulation or pulse frequency modulation, the PWM offers significant advantages, for instance in terms of ease of implementation, constant frequency in- verter operation, immediate demodulation by means of simple low-pass filters. e analog imple- mentation of PWM, also known as naturally sampled PWM, is indeed extremely easy, requiring, in principle, only the generation of a suitable carrier (typically a triangular or sawtooth waveform) and the use of an analog comparator. A simple PWM circuit is shown in Fig. 2.3.
- Assistant
在任何转换器控制设计中,定义合适的调制法则是第一步。许多调制技术已经为开关模式电源开发,对于VSI情况来说,最成功的无疑是脉宽调制(PWM)。与脉密度调制或脉频调制等其他方法相比,PWM具有显著的优势,例如易于实现、恒定频率逆变器操作、通过简单的低通滤波器进行即时解调。PWM的模拟实现,也称为自然采样PWM,确实非常简单,原则上只需要产生一个合适的载波(通常是三角波或锯齿波形),并使用模拟比较器即可。简单的PWM电路如图2.3所示。
- User
Considering the circuit and what has been explained in Section 2.1, it is easy to see that, as a result of the analog comparator and driving circuitry operation, a square-wave voltage VOC will be applied to the load, with constant frequency fS D 1=TS , TS being the period of the carrier signal c.t/, and variable duty-cycle d . is is implicitly defined, again from Fig. 2.3, as the ratio between the time duration of the CVDC voltage application period and the duration of the whole modulation period, TS . Finally, Fig. 2.3 allows to see the relation between duty-cycle and the average value (in the modulation period) of the load voltage, that is calculated in the Aside 1. It is now interesting to explicitly relate signal m.t / to the resulting PWM duty-cycle. Sim- ple calculations show that, in each modulation period, where a constant m is assumed, the fol- lowing equation holds: 翻译
- Assistant
考虑电路和第2.1节中解释的内容,可以很容易地看出,在模拟比较器和驱动电路的操作下,一个具有恒定频率fS=1/TS的方波电压VOC将被施加到负载上,并具有可变占空比d。根据图2.3,占空比可以隐式地定义为CVDC电压施加周期的时间持续与整个调制周期TS持续时间持续时间的比率。最后,图2.3显示了占空比与负载电压平均值(在调制周期内)之间的关系,这可以在Aside 1中计算得到。
现在可以将信号m(t)明确地与结果PWM占空比相关联。简单的计算表明,在每个假定常量m的调制周期中,以下方程式成立:
- User
It is now interesting to explicitly relate signal m.t / to the resulting PWM duty-cycle. Sim- ple calculations show that, in each modulation period, where a constant m is assumed, the fol- lowing equation holds:
- Assistant
现在我们需要把信号m(t)明确地与产生的PWM占空比相关联。简单的计算表明,在每个假定常量m的调制周期中,以下方程式成立:
d=m/|c(t)|
其中,|c(t)|表示载波信号的无符号幅度。该方程式描述了信号m(t)如何控制PWM占空比的变化。
- User
If we now assume that the modulating signal changes slowly along time, with respect to the carrier signal, i.e., that the upper limit of m.t/ bandwidth is well below 1=TS , we can still consider the result (2.3) correct. is means that, in the hypothesis of a limited bandwidth m.t/, the information carried by this signal is transferred by the PWM process to the duty-cycle, that will change slowly along time following the m.t/ evolution. e duty-cycle, in turn, is transferred to the load voltage waveform by the power converter. e slow variations of the load voltage average value will therefore copy those of signal m.t /.
- Assistant
如果我们现在假设调制信号相对于载波信号而言变化缓慢,即m(t)的频带上限远低于1 / TS,则仍然可以认为结果(2.3)是正确的。这意味着,在假定调制信号频带受限的情况下,该信号携带的信息将通过PWM过程传递给占空比,而占空比将沿着m(t)演变缓慢地变化。反过来,功率转换器将占空比转移到负载电压波形上。负载电压平均值的缓慢变化将因此复制信号m(t)的变化。
- User
e simplified discussion above may be replaced by a more mathematically sound approach, that an interested reader can find in power electronics textbooks like [4], [5], and [6]. However, this approach would basically show that the harmonic frequency content, i.e., the spectrum, of the modulating signal m.t/ is shifted along frequency by the PWM process, and is replicated around all integer multiples of the carrier frequency. is implies that, as long as the spectrum of signal m.t/ has a limited bandwidth with a upper limit well below half of the carrier frequency, signal demodulation, i.e., the reconstruction of signal m.t/ spectrum from the signal VOC.t/, with associated power amplification, can be easily achieved by low-pass filtering VOC .t /. In the case of power converters, like the one we are considering here, the low-pass filter is actually represented by the load itself. Referring again to Fig. 2.1 and to Aside 1, it is possible to see that the transfer function between the inverter voltage VOC and load current IO indeed presents a single-pole low-pass filter frequency response. e pole is located at an angular frequency that is equal to the ratio between load resistance RS and load inductance LS . Because of that, we can assume that, if the load time constant, LS =RS , is designed to be much higher than the modulation period TS , the load current IO average in the modulation period will precisely follow the trajectory determined by signal m.t/. is is the situation described by Fig. 2.4. It is worth noting that, while the average current is suitably sinusoidal, the instantaneous current waveform is characterized by a residual switching
- Assistant
上述简化的讨论可以被更加数学严谨的方法所取代,感兴趣的读者可以在电力电子教材[4]、[5]和[6]中找到。然而,这种方法基本上会表明,调制信号m(t)的谐波频率内容,即频谱,通过PWM过程沿频率方向移动,并在载波频率的所有整数倍上复制。这意味着,只要信号m(t)的频谱具有有限的带宽,其上限远低于载波频率的一半,信号解调,即从信号VOC(t)中重构信号m(t)谱,并带有相应的功率放大,可以通过低通滤波器VOC(t)轻松实现。在类似本节讨论的功率转换器中,低通滤波器实际上由负载本身代表。
再次参考图2.1和Aside 1,可以看出逆变器电压VOC和负载电流IO之间的传递函数确实呈现单极低通滤波器的频率响应。极点位于一个角频率上,该角频率等于负载电阻RS和负载电感LS之比。因此,我们可以假设,如果负载时间常数LS =RS被设计得比调制周期TS高得多,那么负载电流IO在调制周期内的平均值将准确地遵循由信号m(t)确定的轨迹。这是图2.4所描述的情况。值得注意的是,虽然平均电流适当地呈正弦形,但瞬时电流波形的特征是残留的开关翻转。
- User
noise, the current ripple. is is a side effect determined by the non ideal filtering of high-order modulation harmonics, given by the load low-pass characteristics.
- Assistant
这种噪声即是电流纹波。这是由于高阶调制谐波通过负载低通特性的不完