In practice, the maximum current absolute value will be limited as well, mainly because…
- User
In practice, the maximum current absolute value will be limited as well, mainly because of the limited current handling capability of the active devices. is limitation, differently from the previous ones, is not inherent to the circuit topology and will need to be enforced by a current controller, in order to prevent accidental damage to the switches, for example in the case of a short circuit in the load. What should be clear by now is that any controller trying to impose voltages, currents, or current rates of change beyond the above-described limits will not be successful: the limit violation will simply result in what is called inverter saturation. It is worth adding that, in our following discussion, we will consider linear models of the VSI, capable of describing its dynamic behavior in a small-signal approximation. Events like inverter saturation, typical of large-signal inverter operation, will not be correctly modeled. In order to further clarify these concepts, the derivation of a small-signal linear model for the VSI inverter of Fig. 2.1 is presented in the Aside 1. In the most general case, the VSI controller is organized hierarchically, in a multi-level, or multi-layer, architecture. At the bottom layer a controller determines the state of each of the two switches, and in doing so, the average load voltage. is layer is called the modulator layer. e strategy according to which the state of the switches is changed along time is called the modulation law. e input to the modulator is the set-point for the load average voltage, normally provided by a higher-level control loop. A direct control of the average load voltage is also possible: in this case the VSI is said to operate in open loop conditions. However, this is not a commonly adopted mode of operation, since no control of load current is provided in the presence of load parameter variations. 翻译
- Assistant
在实践中,最大电流绝对值也会受到限制,主要是由于有源器件的电流处理能力受限。这种限制与之前的限制不同,不是电路拓扑结构固有的,需要通过电流控制器强制执行,以防止负载短路等意外损坏开关的情况。现在应该清楚的是,任何试图施加超出上述限制的电压、电流或电流变化速率的控制器都不会成功:限制违规简单地导致逆变器饱和。值得补充的是,在我们接下来的讨论中,我们将考虑逆变器的线性模型,能够描述其在小信号近似下的动态行为。大信号逆变器操作时 typi的饱和等事件将无法正确建模。为了进一步阐明这些概念,在Aside 1中介绍了Fig.2.1的VSI逆变器的小信号线性模型的推导过程。在最一般的情况下,VSI控制器采用多层次或多层次架构进行组织。在最底层,一个控制器确定每个开关的状态,以及平均负载电压。这个层次称为调制器层。沿时间改变开关状态的策略称为调制定律。调制器的输入是负载平均电压的设定点,通常由更高级别的控制环提供。也可以直接控制平均负载电压:在这种情况下,VSI被称为在开环条件下运行。然而,这不是常用的操作模式,因为在负载参数变化存在的情况下,没有提供负载电流的控制。
- User
Because of that, in the large majority of cases, a current controller can be found immedi- ately above the modulator layer. is is responsible for providing the set-point to the modulator. Similarly, the current controller set-point can be provided by a further external control loop or directly by the user. In the latter case, the VSI is said to operate in current mode, meaning that the control circuit has turned a voltage source topology into a controlled current source. We will deal with further external control loops in one of the following chapters; for now, we will focus on the modulator and current control layers. Indeed, the main purpose of this chapter is exactly to explain how these two basic controller layers are organized and how the current regulators can be properly designed.
- Assistant
因此,在绝大多数情况下,电流控制器可以立即找到在调制器层上方。它负责向调制器提供设定点。同样地,电流控制器设定点可以由进一步的外部控制环路或直接由用户提供。在后一种情况下,VSI被称为在电流模式下运行,这意味着控制电路已将电压源拓扑转化为可控电流源。我们将在以下章节中处理更多的外部控制环路;现在,我们将重点介绍调制器和电流控制层。实际上,本章的主要目的就是解释这两个基本的控制器层如何组织以及如何正确设计电流调节器。
- User
Before we move to describe the modulator layer, one final remark is needed to complete the expla- nation of the VSI operation. e issue we want to address here is known as switching dead-time. It is evident from Fig. 2.1 that in no condition the simultaneous conduction of both switches should be allowed. is would indeed result into a short circuit across the input voltage sources, leading to an uncontrolled current circulation through the switches and, very likely, to inverter fatal damage. Any modulator, whatever its implementation and modulation law, should be protected against this event. In the ideal switch hypothesis of Section 2.1.1, the occurrence of switch cross con- duction can be easily prevented by imposing, under any circumstances, logically complementary gate signals to the two switches. Unfortunately, in real life cases, this is not a sufficient condition to avoid cross conduction. It should be known from basic power electronics knowledge that real switch commutations require a finite amount of time and that the commutation time is a rather complex function of several variables among which are the commutated current and voltage, the gate drive current, the device junction temperature and so on. It is therefore impossible to rely on complementary logic gate signals to protect the inverter.
- Assistant
This is where the concept of switching dead-time comes into play. By adding a short period of time between turning off one switch and turning on the other one, we can prevent switch cross-conduction. During this dead-time, both switches are off, and the voltage across the inductor is clamped by the input voltage sources. In practice, the dead-time is typically on the order of nanoseconds to microseconds, depending on the switching frequency and the characteristics of the devices being used.
Switching dead-time can be implemented in different ways, but the most common approach is to add a dedicated dead-time circuit between the modulator and the gate drivers. This circuit generates the complementary delay signals for the two switches, ensuring that the dead-time is properly enforced. The dead-time can be fixed or adaptive, depending on the specific application requirements.
In summary, switching dead-time is a crucial concept in VSI design, and it should always be taken into account when designing the modulator and gate drive circuits. Failure to properly enforce dead-time can lead to switch cross-conduction, which can cause serious damage to the inverter.
- User
翻译
- Assistant
在我们转向描述调制器层之前,需要进行最后一点备注来完成对VSI操作的解释。我们想要讨论的问题是所谓的开关死区时间。从图2.1中可以看出,在任何情况下都不应允许同时导通两个开关。这实际上会导致输入电压源之间的短路,导致通过开关的无控制电流循环,并很可能导致逆变器的损坏。任何调制器,无论其实现方式和调制定律如何,都应该受到此类事件的保护。在第2.1.1节的理想开关假设中,可以通过在任何情况下对两个开关施加逻辑互补的门信号来轻松防止开关交叉导通。不幸的是,在实际情况下,这不是避免交叉导通的充分条件。应该知道,基本功率电子学的知识中,实际开关换流需要一定的时间,并且换流时间是几个变量的相当复杂的函数,其中包括交换的电流和电压、门驱动电流、器件结温度等。因此,无法依靠互补逻辑门信号来保护逆变器。
这就引出了开关死区时间的概念。通过在关闭一个开关和开启另一个开关之间添加短时间,我们可以避免开关交叉导通。在这个死区时间内,两个开关都处于关闭状态,电感器上的电压由输入电压源夹紧。实际上,死区时间通常是纳秒到微秒的量级,取决于切换频率和所使用设备的特性。
开关死区时间可以采用不同的方式实现,但最常见的方法是在调制器和门驱动器之间添加专用的死区电路。该电路为两个开关生成互补延迟信号,确保死区时间得到正确执行。死区时间可以固定或自适应,具体取决于具体的应用要求。
总之,开关死区时间是VSI设计中至关重要的概念,当设计调制器和门驱动电路时应始终考虑。如果未能正确执行死区时间,可能导致开关交叉导通,从而对逆变器造成严重的损坏。