Slide 1: Title Slide- Troubleshooting and Next Steps in Genomic Library…
- User
Slide 1: Title Slide- Troubleshooting and Next Steps in Genomic Library ConstructionSlide 2: Overview- Summary of project and challenges encountered- Importance of troubleshooting and optimizationSlide 3: Low DNA Concentrations- Effect on gel electrophoresis results- Solutions: Clean up methods and optimizing digestion reactionsSlide 4: Contamination Issues- Effects on transformation results- Solutions: Proper lab practices and appropriate controlsSlide 5: Inefficient Transformation- Errors in competent cell preparation, ligation reaction, and transformation protocol- Solutions for optimization in these areas discussed in the following slidesSlide 6: Ligation Reaction Optimization- Re-evaluating insert-to-vector ratio- Adjusting incubation times and temperatureSlide 7: Transformation Conditions Optimization- Testing different temperature and duration settings for heat shock- Ensuring optimal recovery time for transformed cells- Using appropriate antibiotic concentrations for selectionSlide 8: Alternative Experimental Approaches- Investigating alternative restriction enzymes, plasmid vectors, and competent cell strainsSlide 9: Ensuring Proper Controls and Recovery Conditions- Importance of including positive and negative controls in every experiment- Providing nutrient-rich media during recovery and proper plating methodsSlide 10: Conclusion- Troubleshooting and optimization are critical for successful genomic library construction- Future experiments can enhance efficiency by considering alternative enzymes, plasmids, competent cells, and improving techniquesSlide 11: Next Steps1. Re-evaluate and optimize the transformation process2. Test alternative restriction enzymes, plasmid vectors, and competent cell strains3. Ensure appropriate controls, recovery conditions, and nutrient-rich media are used in each experiment4. Continue troubleshooting and optimizing other areas of the experiment as necessarySlide 12: Acknowledgements and References- Thank any individuals involved in the project- List relevant references used throughout the experiment and presentation
I mentioned the format of my ppt above. make me a ppt script using the information mentioned below and format above:
Background This portion of the lab section involved creating a genomic library using a streptomycin resistant strain of E.coli top10 (4537 bp) as the genomic DNA which will be incorporated into puc19 plasmid (2686 bp) vector as proposed earlier in PART B proposal document. To achieve the proposed plan, E.coli strain top10 (4537 bp) will serve as the genomic strain that will be the source of streptomycin resistance rspL gene. The FastDigest HindIII (thermo scientific) digested fragment will be insert into a digested pUC19 plasmid vector (2686 bp) utilizing ligation process. Once ligated, the product will be transformed with Mach1 chemically competent cells (O.D. value = 0.77). To confirm the success of ligation the transformed product will be plated on Ampillicin/X-gal/IPTG plates and the white colonies will then be streaked onto streptomycin plates to verify the rspl gene streptomycin resistance property. As per the proposal, digesting the bacterial strains with similar digestion enzyme (HindIII) prior to ligation followed by transformation would have ideally given the genomic library however, throughout the project certain decisions were changed based on the results which will be thoroughly covered in this document along with the solutions taken to troubleshoot the mistakes. Methods/Materials Isolation of genomic DNA and plasmid DNA: To start with the procedure of creating a genomic library from E.coli strain Top10 and plasmid pUC19, 5 mL genomic DNA (Top10) and 3 mL plasmid pUC19 was isolated using GeneJET genomic DNA purification kit (lot 01319594) and GeneJET plasmid Mini prep kit (lot 01218820) respectively. Table 1: Observed concentrations of isolated genomic material using SimpliNano. Genomic material A260/A280 A260/A230 DNA Conc. (ng/µL) Top10 1.988 1.644 33.2 pUC19 1.866 1.211 17.2 The above table summarizes the observed concentration data for isolated genomic material on Feb 21, 2023. The volume of sample loaded in SimpliNano was 2 µL for both DNA. Elution buffer(01177350 and 00991597) from both respective isolation kits were used as a blank on SimpliNano. Part B write up 2 Jetul and Japneet April 9, 2023 Restriction Enzyme Digestion: As per part A proposal our group wanted to use HindIII enzyme of restriction enzyme digestion but BamHI was used instead. This was changed because the aim was to check whether BamHI will show same digestion or similar results with strainTop10 of E.coli as it was the case with K12 strain. Both genomic DNA from Top10 and plasmid DNA of pUC19 were digested with thermos scientific FastDigest BamHI enzyme in second week of this project (March 8, 2023) and the reagent volumes used are listed in the table given below. Table 2: Reagents for restriction enzyme digestion of genomic material. Digestion Reagents pUC19 Top10 (rspL gene) Genetic material 2 µL 10 µL Fast digest buffer 2 µL 2 µL BamHI (Fast Digest Enzyme) 1 µL 1 µL PCR Grade Water 30 µL 22 µL Total Reaction volume 35 µL 35 µL This table summarizes the reagent recipe used for first restriction enzyme digestion of genetic materials used to create the genomic library. The above listed both digestion reactions were incubated in 37 °C water bath for 30 minutes before heat inactivation at 80 °C for 10 minutes. Gel electrophoresis to verify digestion from band sizes: This gel electrophoresis was performed on same day in order to confirm whether the digestion was successful or not and whether the isolated genomic DNA contains the rspL gene. To prepare this, 1% gel was prepared using 500 mg BIOTECHNOLOGY GRADE Agarose ITM powder (Lot : 19H2056197) in 50 mL 1X TAE buffer with 2.5 µL INtRON RedSafeTM (0008-090501.52) for visualization. 1Kb DNA ladder RTU (Froggo-BIO, BIO-HELIX LOT 14007210104) was used as a standard with Thermo Scientific 6X loading dye (LOT 00799325). 10 µL of digested genomic was loaded into the gel. Gel was run for 20 minutes at 120V. When analyzed under UV light(Midi Blue LED Transilluminator), there were no bands visible. DNA clean-up: Since gel electrophoresis results indicated no bands it was decided with the help of lab instructor to perform a DNA clean up for genomic to concentrate it more. Originally isolated genomic Top10 DNA was cleaned up using “Thermo Scientific GeneJET Gel Extraction and DNA clean up kit” the following week ( March 14, 2023). A small change was introduced in original clean up protocol which stated “10 µL of Elution buffer” to elute which Part B write up 3 Jetul and Japneet April 9, 2023 was updated to “15 µL of Elution Buffer”. Concentration of genomic DNA was checked on SimpliNano after clean up which indicated the DNA was lost in clean up process. Table 3: Concentration of genomic DNA (Top10) analyzed on SimpliNano after DNA clean up. Cleaned up genomic Top10 DNA A260/A230 0.826 A260/A280 1.609 ng/ µL 12 The above table lists the concentration of originally isolated genomic DNA of strain Top10 after clean-up using Thermo Scientific GeneJET Gel Extraction and DNA clean up kit (LOT 2599306). Volume of sample loaded on SimpliNano was 2 µL and the blank used was the elution buffer(LOT 01307087) from the DNA clean up kit. New isolated genomic Top10 DNA provided by Vanessa: Since the whole genomic DNA was lost therefore another vial of isolated genomic was provided by lab instructor. The concentration of new genomic DNA was analyzed on SimpliNano which was then cleaned-up using the same clean up kit with same modification of 15 µL elution buffer. After clean up the concentration was checked on SimpliNano and is stated in table below. Table 4: Concentration of new genomic Top10 DNA before and after clean-up. Before clean up After clean up A260/A280 1.598 1.794 A260/A230 1.143 2.188 ng/ µL 28.1 109.6 The above table summarizes the observed concentrations of new isolated genomic top10 DNA provided by Vanessa. These concentrations refer to the DNA before using GeneJET genomic DNA purification kit with its corresponding elution buffer as blank. Also after clean up using Thermo Scientific GeneJET Gel Extraction and DNA clean up kit (LOT 2599306). Volume of sample loaded on SimpliNano was 2 µL and the blank used was the elution buffer(LOT 01307087) from the DNA clean up kit. New Digestion reaction set up with cleaned up genomic DNA: The new digestion was performed using the cleaned up genomic DNA with higher concentration. The table summarizes the reaction reagents and volumes. Table 5: The reaction reagents for restriction enzyme digestion of both genomic material. pUC19 Top10 genomic DNA Concentration 17.2 ng/ µL 109.6 ng/ µL Genomic material 4 µL 5 µL Fast Digest Buffer 2 µL 2 µL Part B write up 4 Jetul and Japneet April 9, 2023 Fast Digest Enzyme (BamHI) 1 µL 1 µL PCR Grade water 28 µL 27 µL Total reaction volume 35 µL 35 µL The table gives the reaction volumes that were used to perform enzyme digestion of both genetic materials used in this project to construct a genomic library. Both reactions were incubated for half an hour in 37 °C water bath prior to heat inactivation at 80 °C for 10 minutes. The digestion reactions were then stored in ice bucket until gel electrophoresis apparatus was ready. Another 1% gel electrophoresis: Similar recipe of 1% gel electrophoresis was prepared using same supplies however since the concentration of newly cleaned genomic DNA was significantly high, only 5 µL of cut and uncut genomic along with cut plasmid with 6X loading dye was loaded. The 1% gel was shared with another group with ladder in the center followed by uncut genomic, cut genomic and cut plasmid from our samples. First half of the gel was utilized by Mahan’s group. The gel was run for about 20-25 minutes at 120 V and the results were first visualized under UV light (Midi Blue LED Transilluminator) and then under BIOrad software which will be added in result section. Ligation with only one reaction: This was decided to check if the ligation was successful or not which was performed the following week (March 21, 2023). To do so, a 1:1 ratio of cut plasmid pUC19 and cut genomic top10 (insert) was ligated using T4 ligase (vector) accompanied with the use of PEG4000. The following table summarizes the reaction reagents and volumes. Table 6: Ligation reaction set up for digested insert and vector using T4 ligase. Reaction reagents Ligation ratio (1:1) Insert (digested genomic top10 DNA) 3 µL Vector (digested pUC19) 3 µL T4 Ligase Buffer (5X) 5 µL T4 Ligase 2 µL PEG4000 2 µL PCR Grade water 10 µL Total reaction volume 25 µL This ligation reagent recipe was used to ligate the insert and vector achieved from restriction enzyme digestion of genomic top10 and pUC19 with BamHI. This ligation reaction was incubated overnight at 4 °C and heat inactivated after 24 hours at 65 °C for 10 minutes. The ligated product was then stored at -20 °C until transformation. Transformation with Mach 01 strain competent cells: Part B write up 5 Jetul and Japneet April 9, 2023 Transformation of the ligated product was performed the same week (March 24, 2023). To proceed with transformation, 4 vials of competent cells (50 µL each) were provided by Vanessa along with 4 agar plates. Goal was to plate one positive control, one negative control for validation of results with one experimental in duplicates. Protocol of transformation was used to first thaw the competent cells on ice (about 20 minutes) followed by setting up controls and experimental. Table 7: Controls and experimental reaction set for transformation of ligated product. Reaction Positive control Negative control Experimental Reagents 50 µL competent cells + 10 µL pUC19 50 µL of competent cells 50 The transformation reactions were then incubated on ice for 30 minutes prior to heat shock at 42 °C for 30 seconds. The reactions were then placed on shaker for 1 hour until recovered. Meanwhile, when 30 minutes were left while cells were recovering, 4 agar plates were spread with 100 µL of 25 mg/mL Ampicillin, 40 µL of 20 mg/mL X-gal and 8 µL of 500 mM IPTG per plate respectively. After successive completion of 1 hour recovery of cells, one little change was introduced in which the cells were pelleted at 5000 rpm for 5 minutes. Instead of plating 200 µL onto plates, 150 µL was plated for each to increase the concentration. Once solidified, all 4 plates were incubated at 35 ° C for 24 hours. Plates were retrieved from incubator the next day (March 25, 2023). The results of transformation depicted signs of contamination and no white colonies were present. On the assumption that contamination might have masked the ligation results. New transformation using same ligated product: The following week (March 28, 2023), the same ligated product was used for transformation using same supplies as in previous section. No ligation control was set up as there was not enough ligated product left. Following exact same procedure the transformation was completed and plates were incubated at 35 ͦ C for 24 hours. Plates were retrieved from incubator the next day (March 29, 2023). The results suggested no success since no white colony was visible. Digesting with BamHI and HindIII : In the final week (April 4, 2023) of this project, a new digestion reaction was set up using two restriction enzymes that is FastDigest HindIII (thermo scientific) and FastDigest BamHI (thermo scientific). The reaction reagents and volumes used are listed in the table given below Part B write up 6 Jetul and Japneet April 9, 2023 Table 9: The reaction reagents for restriction enzyme digestion of both genomic material using two enzymes. pUC19 Top10 genomic DNA Concentration 17.2 ng/ µL 109.6 ng/ µL Genomic material 2 µL 2 µL Fast Digest Buffer 1 µL 1 µL Fast Digest Enzyme (BamHI) 2 µL 2 µL Fast Digest Enzyme (HindIII) 2 µL 2 µL PCR Grade water 3 µL 3 µL Total reaction volume 10 µL 10 µL The table enlists the reaction volumes that were used to perform enzyme digestion of both genetic materials with thermos scientific FastDigest BamHI and HindIII. Both digestion reactions were incubated for half an hour in 37 °C water bath prior to heat inactivation at 80 °C for 10 minutes. The digestion reactions were then stored in ice bucket until gel electrophoresis apparatus was ready. Gel electrophoresis to verify digestion of genomic material using 2 restriction enzymes: While performing the digestion reactions one team member was setting up the 1% agarose gel preparation. To do so, 500 mg BIOTECHNOLOGY GRADE Agarose ITM powder (Lot : 19H2056197) was used in 50 mL 1X TAE buffer. 2.5 µL INtRON RedSafeTM (0008-090501.52) was added to the mixture once cool enough. 1Kb DNA ladder RTU (Froggo-BIO, BIO-HELIX LOT 14007210104) was used as standard. About 10 µL of the sample with 2 µL loading dye was used to load digested genomic top10 , digested genomic , undigested pUC19 plasmid , digested plasmid were loaded along with the standard using Thermo Scientific 6X loading dye (LOT 00799325). Once the set up was ready and the 30 minutes incubation was complete, the 1% gel electrophoresis was performed was 20 minutes at 120V. On completion the gel was visualized under UV light (Midi Blue LED Transilluminator). The gel results were not up to mark but since there was no time to carry out any other procedures this project came to an end. Results Part B write up 7 Jetul and Japneet April 9, 2023 Image 1: Picture of first 1% gel electrophoresis performed to confirm the presence of rspL gene after digestion of genomic DNA with BamHI The above image was captured from UV light analysis of the 1% agarose gel prepared in 1X TAE buffer with 2.5 µL INtRON RedSafeTM and 6X loading dye. The well labelled 1 was utilized for 1Kb plus DNA ladder RTU (FroggoBI0- BIOHELIX), 5 µL loaded as standard whilst the well labelled 2 contains the digested genomic DNA (10 µL digested sample + 2 µL loading dye). The above gel electrophoresis was run at 120 V for 20 minutes. Genomic uncut was not loaded which was considered an error. Moreover, there were no bands at all and the problem was low concentration of genomic DNA. It was noticed that since INtRON RedSafeTM requires at minimum 50 ng/ µL of the sample concentration to give any visualization detection effects, the above gel electrophoresis was unsuccessful. This is because the concentration of originally isolated genomic Top10 DNA was already quite low with 33.2 ng/ µL and while preparing the digestion reaction with total volume of 35 µL we used 10 µL of the genomic DNA which implies that our genomic was diluted. Not only this when we loaded 10 µL digested sample with 2 µL loading dye it further diluted. As per this, the concentration of loaded sample was 33.2 ng/ µL which is very less than 50 ng/ µL as per the RedSafeTM to work efficiently. Calculations of digested sample concentration: (33.2 ng / µL × 10 µL in digestion) / (10 µL while loading) = 33.2 ng/ µL
- Assistant
Slide 1: Title Slide
- Troubleshooting and Next Steps in Genomic Library Construction
Slide 2: Overview
- Summary of project and challenges encountered
- Importance of troubleshooting and optimization
Slide 3: Low DNA Concentrations
- Effect on gel electrophoresis results
- Solutions: Clean up methods and optimizing digestion reactions