Background This portion of the lab section involved creating a genomic library using a…
- User
Background This portion of the lab section involved creating a genomic library using a streptomycin resistant strain of E.coli top10 (4537 bp) as the genomic DNA which will be incorporated into puc19 plasmid (2686 bp) vector as proposed earlier in PART B proposal document. To achieve the proposed plan, E.coli strain top10 (4537 bp) will serve as the genomic strain that will be the source of streptomycin resistance rspL gene. The FastDigest HindIII (thermo scientific) digested fragment will be insert into a digested pUC19 plasmid vector (2686 bp) utilizing ligation process. Once ligated, the product will be transformed with Mach1 chemically competent cells (O.D. value = 0.77). To confirm the success of ligation the transformed product will be plated on Ampillicin/X-gal/IPTG plates and the white colonies will then be streaked onto streptomycin plates to verify the rspl gene streptomycin resistance property. As per the proposal, digesting the bacterial strains with similar digestion enzyme (HindIII) prior to ligation followed by transformation would have ideally given the genomic library however, throughout the project certain decisions were changed based on the results which will be thoroughly covered in this document along with the solutions taken to troubleshoot the mistakes. Methods/Materials Isolation of genomic DNA and plasmid DNA: To start with the procedure of creating a genomic library from E.coli strain Top10 and plasmid pUC19, 5 mL genomic DNA (Top10) and 3 mL plasmid pUC19 was isolated using GeneJET genomic DNA purification kit (lot 01319594) and GeneJET plasmid Mini prep kit (lot 01218820) respectively. Table 1: Observed concentrations of isolated genomic material using SimpliNano. Genomic material A260/A280 A260/A230 DNA Conc. (ng/µL) Top10 1.988 1.644 33.2 pUC19 1.866 1.211 17.2 The above table summarizes the observed concentration data for isolated genomic material on Feb 21, 2023. The volume of sample loaded in SimpliNano was 2 µL for both DNA. Elution buffer(01177350 and 00991597) from both respective isolation kits were used as a blank on SimpliNano. Part B write up 2 Jetul and Japneet April 9, 2023 Restriction Enzyme Digestion: As per part A proposal our group wanted to use HindIII enzyme of restriction enzyme digestion but BamHI was used instead. This was changed because the aim was to check whether BamHI will show same digestion or similar results with strainTop10 of E.coli as it was the case with K12 strain. Both genomic DNA from Top10 and plasmid DNA of pUC19 were digested with thermos scientific FastDigest BamHI enzyme in second week of this project (March 8, 2023) and the reagent volumes used are listed in the table given below. Table 2: Reagents for restriction enzyme digestion of genomic material. Digestion Reagents pUC19 Top10 (rspL gene) Genetic material 2 µL 10 µL Fast digest buffer 2 µL 2 µL BamHI (Fast Digest Enzyme) 1 µL 1 µL PCR Grade Water 30 µL 22 µL Total Reaction volume 35 µL 35 µL This table summarizes the reagent recipe used for first restriction enzyme digestion of genetic materials used to create the genomic library. The above listed both digestion reactions were incubated in 37 °C water bath for 30 minutes before heat inactivation at 80 °C for 10 minutes. Gel electrophoresis to verify digestion from band sizes: This gel electrophoresis was performed on same day in order to confirm whether the digestion was successful or not and whether the isolated genomic DNA contains the rspL gene. To prepare this, 1% gel was prepared using 500 mg BIOTECHNOLOGY GRADE Agarose ITM powder (Lot : 19H2056197) in 50 mL 1X TAE buffer with 2.5 µL INtRON RedSafeTM (0008-090501.52) for visualization. 1Kb DNA ladder RTU (Froggo-BIO, BIO-HELIX LOT 14007210104) was used as a standard with Thermo Scientific 6X loading dye (LOT 00799325). 10 µL of digested genomic was loaded into the gel. Gel was run for 20 minutes at 120V. When analyzed under UV light(Midi Blue LED Transilluminator), there were no bands visible. DNA clean-up: Since gel electrophoresis results indicated no bands it was decided with the help of lab instructor to perform a DNA clean up for genomic to concentrate it more. Originally isolated genomic Top10 DNA was cleaned up using “Thermo Scientific GeneJET Gel Extraction and DNA clean up kit” the following week ( March 14, 2023). A small change was introduced in original clean up protocol which stated “10 µL of Elution buffer” to elute which Part B write up 3 Jetul and Japneet April 9, 2023 was updated to “15 µL of Elution Buffer”. Concentration of genomic DNA was checked on SimpliNano after clean up which indicated the DNA was lost in clean up process. Table 3: Concentration of genomic DNA (Top10) analyzed on SimpliNano after DNA clean up. Cleaned up genomic Top10 DNA A260/A230 0.826 A260/A280 1.609 ng/ µL 12 The above table lists the concentration of originally isolated genomic DNA of strain Top10 after clean-up using Thermo Scientific GeneJET Gel Extraction and DNA clean up kit (LOT 2599306). Volume of sample loaded on SimpliNano was 2 µL and the blank used was the elution buffer(LOT 01307087) from the DNA clean up kit. New isolated genomic Top10 DNA provided by Vanessa: Since the whole genomic DNA was lost therefore another vial of isolated genomic was provided by lab instructor. The concentration of new genomic DNA was analyzed on SimpliNano which was then cleaned-up using the same clean up kit with same modification of 15 µL elution buffer. After clean up the concentration was checked on SimpliNano and is stated in table below. Table 4: Concentration of new genomic Top10 DNA before and after clean-up. Before clean up After clean up A260/A280 1.598 1.794 A260/A230 1.143 2.188 ng/ µL 28.1 109.6 The above table summarizes the observed concentrations of new isolated genomic top10 DNA provided by Vanessa. These concentrations refer to the DNA before using GeneJET genomic DNA purification kit with its corresponding elution buffer as blank. Also after clean up using Thermo Scientific GeneJET Gel Extraction and DNA clean up kit (LOT 2599306). Volume of sample loaded on SimpliNano was 2 µL and the blank used was the elution buffer(LOT 01307087) from the DNA clean up kit. New Digestion reaction set up with cleaned up genomic DNA: The new digestion was performed using the cleaned up genomic DNA with higher concentration. The table summarizes the reaction reagents and volumes. Table 5: The reaction reagents for restriction enzyme digestion of both genomic material. pUC19 Top10 genomic DNA Concentration 17.2 ng/ µL 109.6 ng/ µL Genomic material 4 µL 5 µL Fast Digest Buffer 2 µL 2 µL Part B write up 4 Jetul and Japneet April 9, 2023 Fast Digest Enzyme (BamHI) 1 µL 1 µL PCR Grade water 28 µL 27 µL Total reaction volume 35 µL 35 µL The table gives the reaction volumes that were used to perform enzyme digestion of both genetic materials used in this project to construct a genomic library. Both reactions were incubated for half an hour in 37 °C water bath prior to heat inactivation at 80 °C for 10 minutes. The digestion reactions were then stored in ice bucket until gel electrophoresis apparatus was ready. Another 1% gel electrophoresis: Similar recipe of 1% gel electrophoresis was prepared using same supplies however since the concentration of newly cleaned genomic DNA was significantly high, only 5 µL of cut and uncut genomic along with cut plasmid with 6X loading dye was loaded. The 1% gel was shared with another group with ladder in the center followed by uncut genomic, cut genomic and cut plasmid from our samples. First half of the gel was utilized by Mahan’s group. The gel was run for about 20-25 minutes at 120 V and the results were first visualized under UV light (Midi Blue LED Transilluminator) and then under BIOrad software which will be added in result section. Ligation with only one reaction: This was decided to check if the ligation was successful or not which was performed the following week (March 21, 2023). To do so, a 1:1 ratio of cut plasmid pUC19 and cut genomic top10 (insert) was ligated using T4 ligase (vector) accompanied with the use of PEG4000. The following table summarizes the reaction reagents and volumes. Table 6: Ligation reaction set up for digested insert and vector using T4 ligase. Reaction reagents Ligation ratio (1:1) Insert (digested genomic top10 DNA) 3 µL Vector (digested pUC19) 3 µL T4 Ligase Buffer (5X) 5 µL T4 Ligase 2 µL PEG4000 2 µL PCR Grade water 10 µL Total reaction volume 25 µL This ligation reagent recipe was used to ligate the insert and vector achieved from restriction enzyme digestion of genomic top10 and pUC19 with BamHI. This ligation reaction was incubated overnight at 4 °C and heat inactivated after 24 hours at 65 °C for 10 minutes. The ligated product was then stored at -20 °C until transformation. Transformation with Mach 01 strain competent cells: Part B write up 5 Jetul and Japneet April 9, 2023 Transformation of the ligated product was performed the same week (March 24, 2023). To proceed with transformation, 4 vials of competent cells (50 µL each) were provided by Vanessa along with 4 agar plates. Goal was to plate one positive control, one negative control for validation of results with one experimental in duplicates. Protocol of transformation was used to first thaw the competent cells on ice (about 20 minutes) followed by setting up controls and experimental. Table 7: Controls and experimental reaction set for transformation of ligated product. Reaction Positive control Negative control Experimental Reagents 50 µL competent cells + 10 µL pUC19 50 µL of competent cells 50 The transformation reactions were then incubated on ice for 30 minutes prior to heat shock at 42 °C for 30 seconds. The reactions were then placed on shaker for 1 hour until recovered. Meanwhile, when 30 minutes were left while cells were recovering, 4 agar plates were spread with 100 µL of 25 mg/mL Ampicillin, 40 µL of 20 mg/mL X-gal and 8 µL of 500 mM IPTG per plate respectively. After successive completion of 1 hour recovery of cells, one little change was introduced in which the cells were pelleted at 5000 rpm for 5 minutes. Instead of plating 200 µL onto plates, 150 µL was plated for each to increase the concentration. Once solidified, all 4 plates were incubated at 35 ° C for 24 hours. Plates were retrieved from incubator the next day (March 25, 2023). The results of transformation depicted signs of contamination and no white colonies were present. On the assumption that contamination might have masked the ligation results. New transformation using same ligated product: The following week (March 28, 2023), the same ligated product was used for transformation using same supplies as in previous section. No ligation control was set up as there was not enough ligated product left. Following exact same procedure the transformation was completed and plates were incubated at 35 ͦ C for 24 hours. Plates were retrieved from incubator the next day (March 29, 2023). The results suggested no success since no white colony was visible. Digesting with BamHI and HindIII : In the final week (April 4, 2023) of this project, a new digestion reaction was set up using two restriction enzymes that is FastDigest HindIII (thermo scientific) and FastDigest BamHI (thermo scientific). The reaction reagents and volumes used are listed in the table given below Part B write up 6 Jetul and Japneet April 9, 2023 Table 9: The reaction reagents for restriction enzyme digestion of both genomic material using two enzymes. pUC19 Top10 genomic DNA Concentration 17.2 ng/ µL 109.6 ng/ µL Genomic material 2 µL 2 µL Fast Digest Buffer 1 µL 1 µL Fast Digest Enzyme (BamHI) 2 µL 2 µL Fast Digest Enzyme (HindIII) 2 µL 2 µL PCR Grade water 3 µL 3 µL Total reaction volume 10 µL 10 µL The table enlists the reaction volumes that were used to perform enzyme digestion of both genetic materials with thermos scientific FastDigest BamHI and HindIII. Both digestion reactions were incubated for half an hour in 37 °C water bath prior to heat inactivation at 80 °C for 10 minutes. The digestion reactions were then stored in ice bucket until gel electrophoresis apparatus was ready. Gel electrophoresis to verify digestion of genomic material using 2 restriction enzymes: While performing the digestion reactions one team member was setting up the 1% agarose gel preparation. To do so, 500 mg BIOTECHNOLOGY GRADE Agarose ITM powder (Lot : 19H2056197) was used in 50 mL 1X TAE buffer. 2.5 µL INtRON RedSafeTM (0008-090501.52) was added to the mixture once cool enough. 1Kb DNA ladder RTU (Froggo-BIO, BIO-HELIX LOT 14007210104) was used as standard. About 10 µL of the sample with 2 µL loading dye was used to load digested genomic top10 , digested genomic , undigested pUC19 plasmid , digested plasmid were loaded along with the standard using Thermo Scientific 6X loading dye (LOT 00799325). Once the set up was ready and the 30 minutes incubation was complete, the 1% gel electrophoresis was performed was 20 minutes at 120V. On completion the gel was visualized under UV light (Midi Blue LED Transilluminator). The gel results were not up to mark but since there was no time to carry out any other procedures this project came to an end. Results Part B write up 7 Jetul and Japneet April 9, 2023 Image 1: Picture of first 1% gel electrophoresis performed to confirm the presence of rspL gene after digestion of genomic DNA with BamHI The above image was captured from UV light analysis of the 1% agarose gel prepared in 1X TAE buffer with 2.5 µL INtRON RedSafeTM and 6X loading dye. The well labelled 1 was utilized for 1Kb plus DNA ladder RTU (FroggoBI0- BIOHELIX), 5 µL loaded as standard whilst the well labelled 2 contains the digested genomic DNA (10 µL digested sample + 2 µL loading dye). The above gel electrophoresis was run at 120 V for 20 minutes. Genomic uncut was not loaded which was considered an error. Moreover, there were no bands at all and the problem was low concentration of genomic DNA. It was noticed that since INtRON RedSafeTM requires at minimum 50 ng/ µL of the sample concentration to give any visualization detection effects, the above gel electrophoresis was unsuccessful. This is because the concentration of originally isolated genomic Top10 DNA was already quite low with 33.2 ng/ µL and while preparing the digestion reaction with total volume of 35 µL we used 10 µL of the genomic DNA which implies that our genomic was diluted. Not only this when we loaded 10 µL digested sample with 2 µL loading dye it further diluted. As per this, the concentration of loaded sample was 33.2 ng/ µL which is very less than 50 ng/ µL as per the RedSafeTM to work efficiently. Calculations of digested sample concentration: (33.2 ng / µL × 10 µL in digestion) / (10 µL while loading) = 33.2 ng/ µL
Part B write up 8 Jetul and Japneet April 9, 2023 Hence, nothing was detected.Furthermore, digested pUC19 plasmid and uncut genomic Top10 was not loaded and therefore nothing was there to compare which was a mistake. Image 2: Second 1% gel electrophoresis performed after digesting newly cleaned genomic DNA. The above image represents the picture captured of 1% gel electrophoresis run for 25 minutes at 120 V under UV light. This is the seconds gel that contained new digestion reaction containing the genomic DNA after clean up. The gel was prepared in 1X TAE buffer with 2.5 µL INtRON RedSafeTM along with 6X loading dye used for sample preparations. Gel was shared with another group (Mahan’s) which is represented with the arrow head and samples in lane 1,2,3 belongs to other group. Well labelled 4 contained the 5 µL of 1Kb plus DNA ladder RTU (FroggoBI0- BIOHELIX) , well 5 contained the uncut genomic Top10 (5 µL + 6X loading dye), well 6 contained cut genomic with BamHI((5 µL + 6X loading dye) and well 7 contains the cut plasmid with BamHI ((5 µL + 6X loading dye). Image 3: BIORAD image of 1% gel electrophoresis performed for confirming the action of BamHI on rspL gene of genomic DNA and on plasmid pUC19. Part B write up 9 Jetul and Japneet April 9, 2023 The above image represents the picture captured of 1% gel electrophoresis run for 25 minutes at 120 V under BIORAD Imager. The gel was prepared in 1X TAE buffer with 2.5 µL INtRON RedSafeTM along with 6X loading dye used for sample preparations. Gel was shared with another group (Mahan’s) which is represented with the arrow head and samples in lane 1,2,3 belongs to other group. Well labelled 4 contained the 5 µL of 1Kb plus DNA ladder RTU (FroggoBI0- BIOHELIX) , well 5 contained the uncut genomic Top10 (5 µL + 6X loading dye) which as expected showed a large uncut band, well 6 contained cut genomic with BamHI((5 µL
- 6X loading dye) which showed a large smear in image and is shorter as compared to the large band of genomic in lane 5 hence suggest the digestion to be complete and well 7 contains the cut plasmid with BamHI ((5 µL + 6X loading dye) which showed two very faint bands as highlighted with red color on image. Image 4: Transformation results containing experiment results and controls after 24-hour incubation at 37 degrees Celsius. Part B write up 10 Jetul and Japneet April 9, 2023 The above image represents the picture captured of agar plates after 24-hour incubation at 37 degrees Celsius. Each of the plates above contains 100 µL of 25 mg/mL Ampicillin, 40 µL of 20 mg/mL X-gal, and 8 µL of 500 mM IPTG. Negative control (C) contains 50 µL of competent cells. Positive control (A) contains 50 µL of competent cells and 5 µL of pUC19. Experiment plates are in duplicate (B , D) and contains 50 µL of competent cells and 10 µL of ligated product. The experiment failed since the positive control contains contamination (the big white colonies shown in the image are contamination). Image 5: Transformation results containing experiment results and controls after 24-hour incubation at 37 degrees Celsius. Experiment was performed due to failure of the first one. Part B write up 11 Jetul and Japneet April 9, 2023 The above image represents the picture captured of agar plates after 24-hour incubation at 37 degrees Celsius. Each of the plates above contains 100 µL of 25 mg/mL Ampicillin, 40 µL of 20 mg/mL X-gal, and 8 µL of 500 mM IPTG. Negative control (D) ,Positive control (C) ,experiment plates (A,B) in duplicate contain the contents as mentioned in Image 4 above The experiment was not successful due to plating issue. There is inefficient uptake of DNA by host organism which led to inefficient transformation that mean unsuccessful transformation. Part B write up 12 Jetul and Japneet April 9, 2023 Image 6: Third 1% gel electrophoresis performed using HindIII and BamHI. The above image represents the picture captured of 1% gel electrophoresis run for around 45 minutes at 120 V under UV light. This is the third gel that contained a new digestion reaction containing the genomic DNA. The gel was prepared in 1X TAE buffer with 2.5 µL INtRON RedSafeTM along with 6X loading dye used for sample preparations. Well labelled 1 contained the 10 µL of 1Kb plus DNA ladder RTU (FroggoBI0- BIOHELIX), well labelled 2 contained the undigested genomic Top10 (10 µL + 6X loading dye), well labelled 3 contained digested genomic with BamHI and HindIII (10 µL + 6X loading dye), well labelled 4 contains the undigested plasmid (10 µL + 6X loading dye) and well labelled 5 contains the digested plasmid with BamHI and HindIII (10 µL + 6X loading dye). Image 7: Information regarding the total length of the genomic Top 10 DNA using restriction analyzer 1 2 3 4 5 1 kb DNA ladder Undigested genomic Digested genomic Undigested pUC19 Digested pUC19 Part B write up 13 Jetul and Japneet April 9, 2023 The above image provides information related to the total length of the genomic Top 10 DNA that is 4537 bp. The tool used for this was restriction analyzer. It also shows that BamHI cuts at 2 different sites on genomic DNA. The cutting positions are 180 and 2865. These sites give very big fragments that can be seen as smear in image 2. This enzyme cuts at 662 on pUC19 and creates sticky ends. The total size of the plasmid is 2686 bp. If we incorporate this plasmid inside a host mentioned above, it gives a smear. There are also chances that host could not uptake the DNA containing rspL gene. Image 8: Information regarding the total length of the genomic Top 10 DNA and cutting positions using HindIII and BamHI enzymes using restriction analyzer. The above image provides information related to the total length of the genomic Top 10 DNA that is 4537 bp. The tool used for this was restriction analyzer. It also shows that BamHI cuts at 2 different sites on genomic DNA and HindIII cuts at 4130 site on genomic DNA. The cutting positions for BamHI are 180 and 2865 and for HindIII is 4130. We used HindIII to make sure that our fragment contains rspL gene. Image 9: Information regarding the total length of the plasmid DNA using restriction analyzer Part B write up 14 Jetul and Japneet April 9, 2023 The above image provides information related to the pUC19 plasmid DNA that is 2686 bp long. The tool used for this was restriction analyzer. It also shows that BamHI cuts at 662 position on plasmid DNA and HindIII cuts at 632 positions. Since we are using two different enzymes, there is a better chance that our fragment contains rspL gene. Discussion The primary objective of this project was to create a genomic library using a streptomycinresistant strain of E.coli Top10 (4537 bp) as the genomic DNA, incorporating it into a pUC19 plasmid (2686 bp) vector (Cirino et al., 2003). The successful construction of this genomic library was expected to confer streptomycin resistance to a recipient E.coli strain Mach1 through the functional selection of the rspL gene (Hanahan, 1983). However, throughout the experiment, several challenges were encountered, leading to changes in the experimental design and troubleshooting of errors. An initial gel electrophoresis performed to confirm the presence of the rspL gene after digestion of genomic DNA with BamHI resulted in no visible bands. This was primarily due to the low concentration of the originally isolated genomic Top10 DNA (33.2 ng/µL), which was further diluted during the digestion reaction and loading of the gel (Inoue et al., 1990). This concentration was below the minimum detection limit required for the INtRON RedSafeTM nucleic acid stain to work efficiently (50 ng/µL). As a consequence, no bands were detected, and the experiment had to be repeated with a new and cleaned up genomic DNA sample. Subsequent gel electrophoresis performed after digesting the cleaned-up genomic DNA with BamHI showed successful digestion of the genomic Top10 DNA, as evidenced by a shorter smear in comparison to the uncut band of the genomic DNA (Sorek et al., 2013). In addition, the plasmid pUC19 showed two very faint bands after digestion with BamHI, indicating appropriate digestion of the plasmid as well. Part B write up 15 Jetul and Japneet April 9, 2023 A ligation reaction was set up using a 1:1 ratio for cut genomic Top10 DNA (insert) and cut plasmid pUC19 (vector) (Chen & Dubnau, 2004). After overnight incubation at 4 °C, the ligated product was transformed into Mach1 chemically competent cells. The initial transformation results were inconclusive due to contamination observed in the positive control plate. Moreover, the second transformation attempt resulted in an unsuccessful transformation due to inefficient uptake of DNA by the host organism, which might have been caused by several factors, such as improper preparation of competent cells, issues concerning the ligation reaction, or the transformation protocol itself (Inoue et al., 1990). To increase the likelihood of obtaining a fragment containing the rspL gene, a third gel electrophoresis was performed using HindIII in addition to BamHI for digesting both genomic Top10 DNA and plasmid pUC19 (Cirino et al., 2003). The use of two different enzymes would increase the accuracy of the construct and facilitate the incorporation of the desired fragment into the plasmid (Hanahan, 1983). Based on the information provided by the restriction analyzer, the BamHI enzyme cuts at two different sites on genomic DNA (180 and 2865), producing large fragments that appeared as a smear in the gel electrophoresis images (Sorek et al., 2013). HindIII was introduced to cut at an additional site (4130) on genomic DNA, increasing the likelihood that the fragment containing the rspL gene would be successfully incorporated into the plasmid (Chen & Dubnau, 2004). In summary, the construction of a genomic library using E.coli Top10 genomic DNA and pUC19 plasmid DNA encountered several challenges throughout the experiment, including low DNA concentrations, contamination, and inefficient transformation (Inoue et al., 1990). The introduction of the HindIII enzyme in addition to BamHI for restriction digestion was expected to increase the probability of obtaining a fragment containing the rspL gene (Cirino et al., 2003). Furthermore, troubleshooting in each area of competent cells preparation, ligation reaction, and transformation protocol can assist in identifying and rectifying these challenges, such as reevaluating the insert-to-vector ratio, incubation time, and temperature for the ligation reaction or testing and optimizing various transformation conditions (Hanahan, 1983). For this experiment, the most likely problem would be with transformation. It could be optimized and modified by making changes mentioned below: a. Temperature and duration: Confirm that the heat shock conditions (e.g. 42°C for 30-45 seconds) are appropriate for your cells (Inoue et al., 1990). b. Recovery duration: Allow adequate time (usually 1 hour) for the cells to recover and express the antibiotic resistance marker (Sorek et al., 2013). c. Optimal antibiotic concentration: Ensure the appropriate concentration of streptomycin for selection is used on the plates. Too high or low of a concentration may result in inadequate selection (Chen & Dubnau, 2004). Part B write up 16 Jetul and Japneet April 9, 2023 In addition to the technical challenges faced during the genomic library construction, human errors could also have contributed to the unsuccessful or inconclusive results. These errors can occur in sample handling, reagent preparation, equipment usage, and protocol execution. Such errors may include:
- Cross-contamination: During handling of samples, there is potential for cross-contamination between different DNA samples or between the samples and reagents, leading to undesired results (Inoue et al., 1990).
- Reagent preparation: Errors can occur while preparing various reagents such as buffers, enzyme solutions, or antibiotics. These could include inaccurate measurement or mixing of components, resulting in incorrect concentrations that can affect experimental outcomes (Sorek et al., 2013).
- Pipetting errors: Inaccurate pipetting can lead to incorrect volumes being dispensed, resulting in the incorrect sample or reagent concentration, which affects the outcome of experiments (Hanahan, 1983).
- Equipment usage: Improper operation, maintenance, or calibration of laboratory equipment can generate unreliable or inconsistent results. For instance, inaccurate temperature settings for incubation or heat shock can affect the transformation efficiency (Chen & Dubnau, 2004). To minimize human errors, it is essential to maintain good laboratory practices, maintaining proper organization of the workspace, labeling samples accurately, and double-checking reagent concentrations. Additionally, regularly calibrating and maintaining equipment, following established protocols carefully, and incorporating appropriate controls into experiments will help reduce the occurrence of human errors and enhance the overall success of the genomic library construction process. Future experiments can investigate alternative restriction enzymes, plasmid vectors, and competent cell strains to improve the overall success of the genomic library construction process (Cirino et al., 2003). Moreover, ensuring a suitable recovery time for transformed cells, providing a nutrient-rich medium during recovery, using appropriate plating methods and conditions, and including positive and negative controls in each transformation experiment will aid in enhancing the efficiency of the genomic library construction and subsequent functional selection of the streptomycin resistance-conferring rspL gene (Hanahan, 1983). Conclusion Part B write up 17 Jetul and Japneet April 9, 2023 In conclusion, the construction of a genomic library using E.coli Top10 genomic DNA and pUC19 plasmid DNA proved to be challenging due to several factors, including low DNA concentrations, contamination, and inefficient transformation. Optimization of the transformation process, selection of alternative restriction enzymes, plasmid vectors, and competent cell strains could enhance the overall success of the genomic library construction and subsequent functional selection of the streptomycin resistance-conferring rspL gene. Future experiments should also emphasize proper controls, recovery conditions, and nutrientrich media to improve the efficiency of this process.
use the above mentioned information and make me a ppt using the format mentioned below:
Deliverable Marks Power Point format of summarized data • Brief background/purpose (3) • Brief experimental set-up with corresponding results (10) o Clear tables figures and legends 13 Troubleshooting and Next Steps • Discussion of results (10) o Possible reasons of error, possible optimization • Discuss next steps to proceed forward in the experiment (3) 13 Supporting References and Citations • Should have at least (3) 3 Presentation • Shared presentation (3) • Total presentation 10-15min maximum (2) 5 Individual Grade • Speaks clearly and confidently (2) • Knowledgeable (2) • Successfully answer questions asked (2) 6 Total Deliverable Grade 40 Lab Partner Rubric Grade 10 Total Presentation Grade 50
- Assistant
Slide 1: Title Slide
- Genomic Library Construction using E.coli Top10 and pUC19
Slide 2: Background/Purpose
- Create a genomic library with E.coli Top10 (streptomycin-resistant strain) as the genomic DNA
- Incorporate it into pUC19 plasmid vector
- Confirm the presence of rspL gene (streptomycin resistance)
Slide 3: Experimental Set-up
- Isolate genomic DNA and plasmid DNA
- Perform Restriction Enzyme Digestion (BamHI, HindIII)
- Gel electrophoresis to verify digestion
- Ligate digested fragments to pUC19 plasmid
- Transform ligated product into Mach1 competent cells
Slide 4: Results (Gel Electrophoresis)
- Image 1: First gel electrophoresis - No visible bands
- Image 2: Second gel electrophoresis - Successful digestion of genomic DNA and plasmid
- Image 3: BIORAD image - Confirmation of digestion
Slide 5: Results (Ligation and Transformation)
- Image 4: Transformation plates - First attempt, contamination in positive control
- Image 5: Transformation plates - Second attempt, unsuccessful transformation
Slide 6: Troubleshooting and Discussion
- Low DNA concentrations
- Contamination
- Inefficient transformation
Slide 7: Next Steps
- Optimize transformation conditions
- Investigate alternative restriction enzymes, plasmid vectors, and competent cell strains
- Ensure suitable recovery time and conditions
Slide 8: Supporting References [1] Cirino, P. C., Mayer, K. M., & Umeno, D. (2003). "Generating mutant libraries using error-prone PCR". Methods in Molecular Biology; Methods and Protocols, 231, 3-9. [2] Hanahan, D. (1983). "Studies on transformation of Escherichia coli with plasmids". Journal of Molecular Biology, 166(4), 557-580. [3] Inoue, H., Nojima, H., & Okayama, H. (1990). "High-efficiency transformation of Escherichia coli with plasmids". Gene, 96(1), 23-28.
Slide 9: Acknowledgements
- Special thanks to lab instructors and classmates for their support and guidance
Slide 10: Questions?