Designing a sterile clean room requires a thorough understanding of the sterile compounding requirements outlined by the United Stated Pharmacopeia (USP). The room needs to be designed to be USP 797 and USP 800 compliant, which means it must meet specific standards for the preparation of sterile products.
Here is a detailed design for a sterile clean room, along with a budget for all materials used to build the room:
-
Room Size and Location:
The sterile clean room should be located in a designated area that is free from potential sources of contamination. The room should be large enough to accommodate the necessary equipment and workspace for sterile compounding. The recommended size for a sterile clean room is 10 feet by 10 feet.
-
Room Construction:
The room should be constructed with smooth, easily cleanable surfaces, such as painted concrete or epoxy-coated concrete floors, and smooth, painted drywall or fiberglass-reinforced plastic (FRP) walls and ceilings. The room should have a single door with a tight seal, and the door should be made of a durable, easy-to-clean material such as stainless steel.
-
Ventilation and Airflow:
The room should have a high-efficiency particulate air (HEPA) filtration system that is capable of filtering out particles down to 0.3 microns in size. The HEPA filtration system should be located outside of the room and connected to the room's ventilation system. The room should also have a positive air pressure system that maintains a slight overpressure compared to the surrounding areas to prevent contamination from entering the room.
-
Lighting:
The room should have adequate lighting to provide a clear view of the sterile compounding process. The lighting should be mounted on the ceiling and should be equipped with HEPA filters to prevent particles from entering the room.
-
Equipment and Furniture:
The room should have a sterile compounding table that is made of a smooth, easily cleanable material such as stainless steel or high-pressure laminate (HPL). The table should have a built-in HEPA filtration system to prevent particles from entering the workspace. The room should also have a sink with a three-compartment sink and a hot and cold water supply. The sink should be made of stainless steel and should be equipped with a HEPA filtration system.
-
Budget:
Here is a budget for all materials used to build the room:
- Room construction: $10,000
- Ventilation and airflow system: $5,000
- Lighting: $2,000
- Equipment and furniture: $10,000
- HEPA filters: $5,000
- Total: $32,000
This budget assumes that the room is being built from scratch and includes the cost of materials, labor, and installation for all components of the sterile clean room. The cost may vary depending on the location and the specific requirements of the clean room.