4.4. Ablation experiments
We analyzed each component of the proposed MFFE through the ablation study. All experiments are conducted on CUB-200-2011 dataset.
4.4.1 Ablation on proposed modules
To gain a deeper understanding of the individual and combined effects of the modules constituting the MFFE framework, we perform a series of ablation experiments. The intent is to quantify the contribution of each module—PM, SD, and FE—to the overall performance of the model. The ablation results are summarized in Table ~\ref{Table2}.
Table 2: Comparison of accuracy on the CUB-200-2011 dataset with different module added to EVA-02-L.
The baseline model, employing the EVA-02-L architecture without additional modules, achieved a commendable top-1 accuracy of 93.39% on the CUB-200-2011 dataset (Table ~\ref{Table2} (a)). Upon integrating the SD module into the baseline (Table ~\ref{Table2} (b)), we observe a notable increment in accuracy, with performance rising to 93.67%. This enhancement of 0.28% suggests that the SD module's capacity to differentiate between categories is crucial to the model's improved discriminative power. The FE module alone is added to the baseline (Table ~\ref{Table2} (c)), leading to an accuracy of 93.63%. While the increase is more modest compared to the SD module, it nonetheless demonstrates the value of refining features to emphasize foreground elements that are pivotal for fine-grained classification tasks. The combined application of the PM and SD modules (Table ~\ref{Table2} (d)) results in a further uplift in accuracy to 93.70%, outperforming the baseline with only the SD module. This indicates a synergistic effect, where multi-scale feature representation from the PM module complements the discriminating capabilities of the SD module. The fusion of the PM and FE modules (Table ~\ref{Table2} (e)), without the SD module, achieves an accuracy of 93.46%. The fusion of the PM and FE modules (Table ~\ref{Table2} (e)), without the SD module, achieves an accuracy of 93.46%. Finally, the incorporation of all three modules—PM, SD, and FE—into the MFFE architecture (Table ~\ref{Table2} (f)) yields the highest accuracy of 93.72%. This result underscores the effectiveness of the full MFFE framework, where each module plays a distinct role that, when combined, leads to the most substantial performance gains.
4.4.2 Effectiveness of feature fusion in SD module
The core of the SD module lies in multi-scale feature fusion. In order to verify the effectiveness of the fusion in the module, we use t-SNE to visualize the salient patch features \mathcal{P_i} of each stage, concatenated features \mathcal{MS}_c and final fusion features \mathcal{MF}, as shown in Figure 4. Here the samples are randomly selected from 30 categories (testing set).
As can be seen from Figure 4, as the stages increase, the features between the same categories become more and more clustered. By the final stage, except for a few categories that are difficult to distinguish, there are obvious inter-category distances between other features. Categories that are difficult to distinguish may require features of other scales for better discrimination. We find that the concatenated features \mathcal{MS}_c is difficult to distinguish from other categories, and the clustering effect is far worse than that of the final stage. We guess that it is because other scale features contain more unimportant information, and simple concatenate is difficult to effectively distinguish categories, so effective multi-scale fusion methods are needed. The \mathcal{MS}_c obtained through multi-scale feature fusion can be clearly distinguished from other features, and categories that are difficult to distinguish can also be distinguished through multi-scale information.
Figure 4: t-SNE visualization of salient patch features \mathcal{P_i} of each stage, concatenated features \mathcal{MS}_c, and final fusion features \mathcal{MF}.
4.4.2 Effectiveness of FE module
The purpose of the FE module is to filter unimportant features and enhance important features. We intuitively demonstrate the effectiveness of this module through attention heatmaps for each stage without and with the FE module, as shown in Figure 5.
As can be seen from Figure 5(b)-(e), without the FE module, the model's area of interest is more cluttered and susceptible to background interference. This may also be the reason why the model misidentifies Bank Swallow as Gray Kingbird. After using the FE module, some background areas are filtered out, and some important discrimination areas can be well highlighted, as shown in Figure 5(f)-(i). As shown in Figure 5(i), the heatmap in the last stage has very few discriminative areas, which will also make it difficult for the model to identify correctly. However, the multi-scale fusion information of the four stages finally enables the model to accurately identify the bird.
Figure 5: Visualization of heatmaps generated from the model without and with FE. (a) Original color image, (b)-(e) heatmaps of each stage of the model without FE, (f)-(i) heatmaps of each stage of the model with FE.
4.4.4 Different Backbone Networks
To better discuss the accuracy improvement brought by this approach, we test the proposed MFFE on four mainstream ViT backbones. As shown in Table 3, the four mainstream backbones, including ViT, Swin-L, Mvitv2-B and EVA-02-L, can be improved after adding our proposed MFFE. The accuracy rate of EVA-02-L before joining MFFE has exceeded state-of-the-art approaches, which shows that when the capacity of the backbone is good enough, the performance in downstream tasks will be quite good. In this experiments, the pre-training dataset for Swin-L is ImageNet-22K, while the others are ImageNet-21K.
Table 3: Improvement of different backbones with our additional structure MFFE.
Backbone Accuracy (%)
Original + MFFE
ViT 84.47 85.47(+1.00)
Swin-L 91.53 91.68(+0.15)
Mvitv2-B 91.63 92.04(+0.41)
EVA-02-L 93.39 93.72(+0.33)