Hello, I need assistance with a detailed calculation related to solar PV system…
- User
Hello, I need assistance with a detailed calculation related to solar PV system integration into a residential electrical panel, and I'm looking for guidance that incorporates both NEC 705.12(D)(2) and the continuous load consideration. The scenario is this: I have a 200-amp main breaker and a 225-amp busbar. According to the NEC, the backfeed from a solar PV system to a panel is subject to the '120% rule', but there's also a need to consider a 125% factor for continuous load. The formula I'm working with is: Backfeed allowed ≤ ((120% of busbar rating) – Ampacity of the overcurrent protection device protecting the busbar) / 125%. Could you help me apply this formula to my scenario and explain the steps and reasoning behind each part of the calculation?
Assistant
Certainly! I can help you work through this calculation step by step.
First, let's clarify the terms we're working with:
- The '120% rule' refers to NEC 705.12(D)(2), which states that the sum of the rated output of all solar PV systems connected to a service or feeder shall not exceed 120% of the rating of the service or feeder.
- The 'continuous load' consideration is a factor that accounts for the fact that solar PV systems produce power continuously, and therefore may require a higher rating for the overcurrent protection device (OCPD) protecting the busbar.
Now, let's apply these considerations to your scenario:
- Determine the rating of the busbar.
- In your case, the busbar has a rating of 225 amps.
- Calculate the maximum allowable backfeed according to the '120% rule':
- 120% of the busbar rating is: 225 amps x 1.2 = 270 amps
- The OCPD protecting the busbar has an ampacity rating that will limit the backfeed. Let's assume this rating is 250 amps.
- Subtract the OCPD ampacity from the maximum allowable backfeed: 270 amps - 250 amps = 20 amps
- Apply the 'continuous load' factor:
- Divide the allowable backfeed by 1.25 (125%): 20 amps / 1.25 = 16 amps
So, in your scenario, the maximum allowable backfeed from the solar PV system is 16 amps, taking into account both the '120% rule' and the 'continuous load' consideration.
I hope this helps! Let me know if you have any further questions.
- User
i said I had 200 amp main breaker
Assistant
My apologies for the misunderstanding! Let's recalculate based on your 200 amp main breaker:
- Determine the rating of the main breaker.
- In your case, the main breaker has a rating of 200 amps.
- Calculate the maximum allowable backfeed according to the '120% rule':
- 120% of the main breaker rating is: 200 amps x 1.2 = 240 amps
- The OCPD protecting the busbar has an ampacity rating that will limit the backfeed. Let's assume this rating is 250 amps.
- Subtract the OCPD ampacity from the maximum allowable backfeed: 240 amps - 250 amps = -10 amps
In this case, the '120% rule' would not allow any backfeed from the solar PV system, as the calculated backfeed is negative. This is because the rating of the main breaker is lower than that of the busbar, which means that the main breaker is the limiting factor in this scenario.
- Apply the 'continuous load' factor:
- Since the calculated backfeed is negative, there would be no allowable backfeed after applying the 'continuous load' factor.
So, based on your 200 amp main breaker, there would be no allowable backfeed from the solar PV system, taking into account both the '120% rule' and the 'continuous load' consideration.
I hope this clarification helps! Let me know if you have any further questions.
- Determine the rating of the main breaker.
- User
the OCPD protecting the busbar = the main breaker!
Assistant
You are correct, my apologies for the confusion! The OCPD protecting the busbar in this case would be the main breaker, which has a rating of 200 amps.
Let's recalculate the allowable backfeed, taking this into account:
- Determine the rating of the main breaker (OCPD).
- In your case, the main breaker has a rating of 200 amps.
- Calculate the maximum allowable backfeed according to the '120% rule':
- 120% of the main breaker rating is: 200 amps x 1.2 = 240 amps
- Subtract the main breaker ampacity from the maximum allowable backfeed: 240 amps - 200 amps = 40 amps
So, the maximum allowable backfeed from the solar PV system is 40 amps, taking into account the '120% rule'.
- Apply the 'continuous load' factor:
- Divide the allowable backfeed by 1.25 (125%): 40 amps / 1.25 = 32 amps
So, the maximum allowable backfeed from the solar PV system is 32 amps, taking into account both the '120% rule' and the 'continuous load' consideration.
I hope this clarification helps! Let me know if you have any further questions.
- Determine the rating of the main breaker (OCPD).
Other models, same or similar prompt
Responses were produced in different, uncontrolled contexts (system prompts, settings, prior turns). This is not a benchmark.