The Modified Compression Field Theory (MCFT) is a method used in the analysis of reinforced concrete structures. It is an extension of the Compression Field Theory (CFT), which is a simplified approach to calculating the strength of reinforced concrete members under axial compression. The CFT assumes that the concrete in compression behaves as a uniformly stressed rectangular block, which is not always the case in reality.
The MCFT modifies the CFT by taking into account the effects of tension stiffening, concrete cracking, and the non-uniform distribution of compressive stress in the concrete. The MCFT is more complex than the CFT, but it provides a more accurate prediction of the strength of reinforced concrete members under axial compression.
The MCFT can be expressed using the equations provided in the Concrete Structures Association (CSA) Handbook. According to the CSA Handbook, the ultimate axial force capacity of a reinforced concrete column under axial compression can be calculated as:
Pu = 0.85 f'c Acon + fy Asteel
where:
- Pu is the ultimate axial force capacity of the column
- f'c is the cylinder compressive strength of the concrete
- Acon is the cross-sectional area of the concrete
- fy is the yield strength of the steel reinforcement
- Asteel is the cross-sectional area of the steel reinforcement
The MCFT modifies this equation by introducing a factor called the Compression Stress Block Factor (CSBF), which takes into account the non-uniform distribution of compressive stress in the concrete. The CSBF can be calculated as:
CSBF = 0.60 - 0.0045 (fc'/fy)
The ultimate axial force capacity of the column can then be calculated as:
Pu = CSBF * f'c * βbc * Acon + fy Asteel
where:
- βbc is the ratio of the breadth of the column to the effective depth
The MCFT also introduces a tension stiffening factor (TSF) to account for the effects of tension stiffening and concrete cracking. The TSF can be calculated as:
TSF = 1 - (0.55 * (fy/f'c)^0.5)
The ultimate moment capacity of the column can then be calculated as:
Mu = TSF * fy * Asteel * d + CSBF * f'c * βbc * Acon * (d - a/2)
where:
- Mu is the ultimate moment capacity of the column
- d is the effective depth of the column
- a is the depth of the compression stress block
These equations provide a more accurate prediction of the strength of reinforced concrete members under axial compression than the simpler CFT equations. However, they are more complex and require more detailed information about the properties of the concrete and steel reinforcement.