These are Slack messages sent from employees talking about sports science. Can you briefly summarize what each person is talking about and what they are concerned about, and what they bring to the table?
kyleb
:large_red_square: 6:45 PM
Given the hitting stuff going on today that reminded me - how are we syncing force plate data with frame-level optical data, or are we / does it not matter? Also how about future EMG integration?
Should we look to drive the edgers using a BMC terminator/adapter and the eSync 2 unit that we can repurpose? Or does Theia3d have a solution? etc (edited)
Joe Marsh
:red_wolves: 6:47 PM
I FUCKIN KNEW YOU WERE GONNA BRING THIS UP
Joe Marsh
:red_wolves: 6:54 PM
I'm going from some memory here but
The most scalable solution is using the auto-trigger (or really any 100% pre-fill trigger option)
configure a DAQ to receive the trigger signal from the Edgertronics
send the trigger to Force plates
write custom software to create a pre-trigger for the force plates
there's no native way to do this in the Bertec SDK so we'll have to do it ourselves
combine the processed theia data with the FP data into a unified .c3d
The worse but wasier solution is to
click a record button before a homie throws a pitch
match edgertronic recording length and framerate divisor to the force plates (e.g. shoot at 250 fps, record force plates at 1000 Hz, for 2 seconds each)
write force plate handling software using the SDK
this can be done with default functions, so it'll be easier
combine the processed theia data with the FP data into a unified .c3d
Will have all these notes in the roadmap
6:54
tl;dr it's possible but probably a decent amount of work
kyleb
:large_red_square: 7:44 PM
Does it matter if they’re synced?
Joe Marsh
:red_wolves: 1:05 AM
I feel like it's more work to record the force plate data not synced to the edgertronic?
If it wasn't synced to the edgertronic then someone would still need to be manually pressing a button to record data
Syncing the trigger isn't the hard part, it's writing custom code using the Bertec SDK (option two is easier because it can just use default commands with bertec or fuck it we could even use motive and trigger the force plates + edgertronics with no other cameras)
kyleb
:large_red_square: 3:04 PM
@Wass
what do you got on the force plate syncing, future data, forward dynamics impact, and any other markerless concerns with mapping the data
New
Wass
:warning: 3:36 PM
The only path to a true trainer-led motion capture experience is full automation via Edger auto-trigger + QR code sign in/facial recognition. As Joe said, that's more work on our part to custom code everything but no third party company is going to satisfactorily solve the problem for us. If it was just about syncing force plates and cameras (and emg), we could just pay MotionMonitor 20,000upfront+2,000/year to do that for us and be set in < 2 months. I know Joe hates their old-ass looking software but, hey, I'm looking forward to the day Visual3D doesn't look like it's from Windows 95 too.
The simplest (internal) framework (but more custom) in my head is the one Joe outlined: autotrigger acts as master sync signal and sends trigger to force plates + edgers (via DAQ or similar). Custom force plate ring buffer software works like Edger pre/post trigger and, assuming the autotrigger signal timing arrives close enough between the plates and the edgers, we have in-sync pre/post trigger recordings from both. This leaves out EMG, which I think is ok for at-largest-scale assessments, although moving to a DAQ would theoretically allow us to talk to the EMG too.
EMG's role in my mind is focused to dedicated projects where more invasive custom collection protocols are employed; the most relevant of which is building and refining the forward dynamics model: we collect a sample of athletes with markered, theia, force plates, and EMG rolling. Adding the EMG inputs to the forward dynamics + CMC pipelines allows us to develop a better model which we can then approximate without EMG at scale at every location that has mocap.
I do not have many, if any, concerns with mapping theia data back to markered mocap data. The paired sample is pretty impressive already and will only continue to grow over the next couple months before we're ready to flip the switch to markerless only. Mapping POIs will be just a matter of using theia POIs to predict markered POIs on a POI by POI basis. Mapping composite scores may or may not be needed, we could just rerun Besky's model development scripts and come up with new composite score questions that are unique to theia data.
If there is a concern with mapping theia to markered, it would be the relative lack of academy data in the current paired dataset. May need additional youth collections to make those conversions robust enough.
:fire:
1
Joe Marsh
:red_wolves: 4:21 PM
I'll add some additional forward dynamics thoughts -
The short version is that we can probably do simulational things without force plates (but handicapped at the level of insights we would get - e.g. we can simulate to optimize for bat speed or velo, but we would be unable to get any insights about actual arm stress). We could 100% NOT do anything in the realm of actual computed muscle control insights.
CMC/ Forward Dynamics:
Requires synced force plate data to calculate muscle activations
Requires EMG to optimize muscle activation profiles
The final product will *basically always require force plates
e.g. ATH mocaps, gets a report that says elbow stress is high given the ATHs mechanics/ strength levels
I say basically always need force plates because there probably exists a world where estimated force plate values are good enough to get what we need
tbh I haven't ever looked at the data that like KinaTrax spits out here
Bertec was interested in offering some sort of product here, I think they know that there exists a world where force plates are never necessary again
EMG is primarily needed to improve muscle activation profiles
Simulations:
Don't require force plates to simulate for certain mechanics profiles (e.g. optimize for velo or bat speed)
Don't require EMG data at all, really
Force plates do add value to simulational insights separate from the CMC things noted above
e.g. optimize mechanics for force put into the bat
e.g. optimize mechanics for knee valgus torques (idk why you would want this, but whatever)
Final product here doesn't necessarily require force plates
e.g. ATH mocaps, gets a report that says you could increase velo by X mph by doing XYZ
it's possible that the suggested mechanical changes (which aren't using FP data in this instance) are actually impractical due to increases in elbow stress, which is another need for force plates
It's sort of a not all rectangles are squares, but all squares are rectangles situation -- Simulations are a component of the CMC insights, but CMC insights aren't necessarily part of the simulation insights.
There's also the combined Simulation/ CMC report which is some sort of deliverables that tell the athlete
increase your velo by doing XYZ
decrease your arm stress by doing ABC
optimize for velo and arm stress by doing IJK
That's a bunch of salad but I think we should sync the force plates to actually get the value out of them that we want to get out of them